www.desatech.com
123721-01E
10
FIREPLACE CLEARANCES
WARNING: Maintain the
minimum clearances shown
in Figure 5. If you can, provide
greater clearances from floor,
ceiling and joining wall.
If your fireplace is to be used with an optional
mantel, the installation instructions included
with your mantel shows an CSA approved
method of attaching the fireplace/mantel sys
-
tem to a wall.
IMPORTANT:
Only use optional
cabinet or corner mantels specified in this
manual. Purchase the optional mantel from
your dealer (see
Accessories,
page 33).
If your fireplace is to be recessed into the wall,
see
Built-In Fireplace Installation
on page 11
to secure your fireplace into the wall.
CAUTION: If you install the
fireplace in a home garage
• fireplace pilot and burner must
be at least 18" above floor.
• locate fireplace where moving
vehicle will not hit it.
For convenience and efficiency, install fire
-
place
• where there is easy access for operation,
inspection and service
• in coldest part of room
An optional blower kit is available from your
dealer. See
Accessories,
page 33. If planning
to use blower, follow instructions provided with
blower for power source.
Minimum Clearances For Side
Combustible Material, Side Wall and
Ceiling
A. Clearances from the side of the fireplace
cabinet to any combustible material and
wall should follow diagram in Figure 5.
Example:
The face of a mantel, bookshelf,
etc. is made of combustible material and
protrudes 3
1
/
2
" from the wall. This com
-
bustible material must be 4" from the side
of the fireplace opening (see Figure 5).
B. Clearances from the top of the fireplace
opening to the ceiling should not be less
than 36".
iNsTallaTioN
Continued
Figure 5 - Minimum Clearance for
Combustible to Wall
*Minimum 16" from Side Wall
*
Example
C. For mantel clearances, see Figure 9 on
page 12.
MINIMUM CLEARANCE TO
COMBUSTIBLE MATERIALS
Top 36", Left and Right Sides 6",
Bottom and Rear 0", Front 36"
BUILT-IN FIREPLACE INSTALLATION
Built-in installation of this fireplace involves
installing fireplace into a framed-in enclosure.
This makes the front of fireplace flush with
wall. An optional trim kit accessory is avail
-
able (see
Accessories,
page 33). Trim will
extend past sides of fireplace approximately
1/2". This will cover the rough edges of the
wall opening. If installing a built-in mantel
above the fireplace, you must follow the clear
-
ances shown in Figure 9, page 12. Follow
the instructions below to install the fireplace
in this manner.
Actual
Framing
Height
26"
26
7
/
8
"
Front Width
26
3
/
4
"
26
7
/
8
"
Depth
14
1
/
4
"
15
1
/
4
"
1. Frame in rough opening. Use dimensions
shown in Figure 6, page 11, for the rough
opening. If installing in a corner, use
dimensions shown in Figure 7, page 11,
for the rough opening. The height is 26
7
/
8
"
which is the same as the wall opening
above.
2. If installing GA3450TA blower accessory,
do so at this time. Follow instructions
included with blower accessory.