OWNER’S MANUAL

VENTING
INSTALLATION

Continued

(Framing

Detail)

10"

(254mm)

10"

(254mm)

1

/

2

"

(190mm)

Vent Opening

Combustible Wall

Vent Opening

Noncombustible Wall

Figure 12 - Vent Opening Requirements

Continued

3.

Attach vent pipe assembly to the fire-
place. Set fireplace in front of it’s per-
manent location to insure minimum
clearances. Mark the wall for a 10"
square hole (for noncombustible ma-
terial such as masonry block or con-
crete, a 7 

1

/

2

" diameter hole is accept-

able). See Figure 12. The center of the
hole should line up with the center-
line of the horizontal rigid vent pipe.
Cut a 10"x10" (254mm x 254mm)
square hole through combustible ex-
terior wall (7 

1

/

2

" [190mm] diameter

hole if noncombustible). Frame as nec-
essary (see Figure 12).

Figure 14 - Installing Vinyl Siding Standoff

Figure  11 - Vent Pipe Connections

Female
Locking
Lugs

Male
Slots

Rigid Vent Pipe Flexible Vent Pipe

Spacer
Spring

4" Clamp

7" Clamp

4" Flex
Pipe

7" Flex
Pipe

Figure 13  - Installing Horizontal Vent Cap

 WARNING: Do not recess vent

termination in to any wall. This
will cause a fire hazard.

4.

Apply a bead of non-hardening mastic
around the outside edge of the vent cap.
Position the vent cap in the center of
the 7 

1

/

2

" or 10" hole on the exterior

wall with the arrow on the vent cap
pointing up. Insure proper clearance of
1" to combustibles is maintained. At-
tach the vent cap with four wood screws
supplied (see Figure 13). 

Note

: Re-

place the wood screws with appropri-
ate fasteners for stucco, brick, concrete,
or other types of siding.

For vinyl siding, stucco, or wood exte-
rior use vinyl siding standoffs between
vent cap and exterior wall. The vinyl sid-
ing standoff prevents excessive heat from
melting the vinyl siding material. Bolt the
vent cap to the standoff. Apply non-hard-
ening mastic around outside edge of the
standoff instead of the vent cap assem-
bly. Use wood screws provided to attach
the standoff. See Figure 14.

5.

Slide the wall thimble over the vent
pipe before connecting the horizontal
run to the vent cap (see Figure 15).

6.

Carefully move the fireplace with vent
assembly attached toward the wall and
insert the vent pipe into the horizontal
termination. The pipe overlap should
be a minimum of 1 

1

/

4

". Apply silicone

to the connection. Fasten all vent con-
nections with screws provided. Refer
to Fireplace Installation on page 16 for
instructions on securing unit to fram-
ing or floor.

7.

Slide the wall thimble against the inte-
rior wall surface and attach with screws
provided (see Figure 15).

Figure 15 - Connecting Vent Cap with
Horizontal Vent Pipe

UP

UP

Cut Vinyl Siding
Away to Fit
Standoff

Wood Screw

Nut

Bolt

Standoff

Vent Cap

Apply Mastic
to All Four Sides

Wood
Screw

Vent Cap

Apply Mastic
to All Four
Sides

Vent Cap
(Horizontal
Termination)

Interior Wall
Surface

Wall
Thimble

Horizontal
Vent Pipe

Screw

Содержание BDV34N

Страница 1: ...fer to this manual for correct in stallation and operational procedures Forassistance or additional information consultaqualifiedinstaller service agency or the gas supplier This appliance may be inst...

Страница 2: ...rly seated and sealed If this unit is not properly installed by a qualified service person with glass door properly seated and sealed gas leakage can occur Carbon Monoxide Poisoning Early signsofcarbo...

Страница 3: ...OR This fireplace has a piezo ignitor This sys tem requires no matches batteries or other sources to light fireplace Figure 1 Vanguard Direct Vent Fireplace BDV Series Glass Door Assembly Blower Adjus...

Страница 4: ...3 20 34 3 4 5 8 for drywall facing Must maintain a minimum 1 clearance to combustibles 34 1 2 34 3 4 20 Vertical Termination 19 Horizontal Termination CLEARANCES Minimum clearances to combustibles for...

Страница 5: ...pe cifically approved for this fireplace Minimum clearance between vent pipes and combustible materials is 1 25 mm except where stated otherwise Combustible material may be flush with the top front of...

Страница 6: ...de walk or a paved driveway located on public property 84 inches 2133mm minimum M clearance under veranda porch deck 12 inches 305mm minimum N clearance above a roof shall extend a minimum of 24 inche...

Страница 7: ...proper length of vent pipe for the type of termination you choose It is also important to note the wall thickness For Horizontal Termination Select the amount of vertical rise desired The horizon tal...

Страница 8: ...appliance adaptor with pipe seams oriented towards the wall or floor Twist lock Procedure The female ends of the pipes and fittings have four locking lugs indentations These lugs will slide straight i...

Страница 9: ...f 1 to combustibles is maintained At tach the vent cap with four wood screws supplied see Figure 13 Note Re place the wood screws with appropri ate fasteners for stucco brick concrete or other types o...

Страница 10: ...for use with corner installation UP Horizontal Venting See information in Figures 17 and 18 for Vertical V and Horizontal H maxi mums and minimums The same amounts apply for flexible venting BVK Vent...

Страница 11: ...max 8 min 8 min 20 max 20 max 8 max 20 max Venting with Two 90 Elbows Vertical V Horizontal H1 Horizontal H2 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max 20 max 20 max Figure 19 Horizontal Termi...

Страница 12: ...as specified in the second warning state ment on page 7 Be sure all pipe and elbow connections are fully twist locked see Figure 11 page 9 3 Cut a hole in the roof using the locating hole as a center...

Страница 13: ...Cut hole 1 8 larger than support box when projected onto roofline 2 minimum below finished ceiling Cathedral ceiling support box Level 3 Lower the support box through the hole in the roof until the b...

Страница 14: ...No Horizontal Run VENTING INSTALLATION Continued Venting with Two 90 Elbows Vertical V1 Horizontal H 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max Note Vertical V1 Vertical V2 20 max Figure 27 V...

Страница 15: ...of Flashing RTV Silicone VerticalTermination and26screws D1000 7 x 12 Galvanized Coaxial Pipe 6 pcs D1010 7 x 24 Galvanized Coaxial Pipe 6 pcs D1020 7 x 48 Galvanized Coaxial Pipe 6 pcs D1030 7 Adjust...

Страница 16: ...un system scirculatingblowerwhile using heater This will help circu late the heat throughout the house In the event of a power outage you can use this heater as your primary heat source NOTICE A quali...

Страница 17: ...the right side see Figure 33 Route power cord through both plastic bushing s and plug the power cord into a properly grounded 3 prong wall receptacle near the firebox b If your fireplace system insta...

Страница 18: ...con nector if allowed by local codes not provided AnA G A design certifiedmanualshutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Pur chase the A G A design certifie...

Страница 19: ...provided by installer from manual shutoff valve to fireplace Route flexible gas supply line through one of the access holes on side of fireplace 3 Attach flexible gas line from gas sup ply to control...

Страница 20: ...gure 39 for natu ral Apply commercial leak test solu tion to all gas joints Bubbles forming show a leak Correct all leaks at once 5 Light fireplace see Operating Fire place pages 24 and 25 Check all o...

Страница 21: ...witch bracket Lean bracket forward so you are able to ac cess the back of the remote receiver 3 Locate the battery clip mounted on the back of the receiver Slide a 9 volt bat tery not included through...

Страница 22: ...ebox see Figure 46 4 Slide the left retainer bracket against the left side brick panel Loosely se cure the bracket screw This secures the left side brick panel 5 Install the right brick panel using th...

Страница 23: ...lace model numbers WARNING Failure to position thepartsinaccordancewiththese diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal inju...

Страница 24: ...not require ac cessing for lighting 8 Turn knob on gas control counter clockwise to PILOT 9 Push in control knob all the way and hold Immediately light the pilot by repeatedly depressing the piezo spa...

Страница 25: ...h is in the ON position In the OFF position the blower will not operate Note for DA3610T Only Your fireplace and blower will not turn on and off at the same time The fireplace may run for sev eral min...

Страница 26: ...ol before cleaning CAUTION Youmustkeepcon trol areas burners and circulat ing air passageways of fireplace clean Inspect these areas of fire place before each use Have fire place inspected yearly by a...

Страница 27: ...loose at con trol valve 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut hold...

Страница 28: ...t warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local pro pane gas company 3 Clean burner see Cleaning and Maintenance page 26 or replace burner orifice...

Страница 29: ...nt above 1 Improper log placement 2 Air holes at burner inlet blocked 3 Burner flame holes blocked OBSERVED PROBLEM Fireplace produces unwanted odors Fireplace shuts off in use Gas odor even when cont...

Страница 30: ...n servicing controls Wiringerrorscancause improper and dangerous opera tion Verify proper operation af ter servicing Red Variable Fan Switch Fan Switch N O Black Black Green White On 110 115 V A C Blo...

Страница 31: ...anifold Pressure 3 5 w c 10 0 w c Minimum Inlet Supply Pressure 4 5 w c 11 0 w c Dimension Inches mm HxWxD Fireplace 33 x 34 x 18 1 2 33 x 34 x 18 1 2 838 x 940 x 470mm 838 x 940 x 470mm Carton 37 x 4...

Страница 32: ...rim accessories Dimensions WxHxD 56 3 4 x48 3 4 x22 7 8 HARDWOOD HEARTH BASE G3000F Series Walnut Finished G3001U Series Unfinished G3006F Series Oak Finished with Medium Stain G3007U Series Unfinishe...

Страница 33: ...lack louvers by screwing into place DECORATIVE 2 PIECE BRASS ACCENT TRIM D7034 Not Shown Thesestripshaveamagneticbackingwhich makes installation and removal quick and easy They are designed to go at t...

Страница 34: ...L PROPANE ILLUSTRATED PARTS BREAKDOWN BDV34N A 1 2 3 4 6 7 7 8 9 10 11 Included in Hardware Pack 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 28 29 30 31 3 31 2 31 4 31 1 32 33 32 34 46 5 5 5 35...

Страница 35: ...Natural 1 18 104497 01 SIT Pilot Natural 1 19 104498 01 Thermocouple 1 20 104499 01 Thermopile 1 21 104500 01 Ignitor 1 22 104501 01 Ignitor Bracket 1 23 104502 01 Ignitor Screw 1 24 104503 01 Ignito...

Страница 36: ...L PROPANE ILLUSTRATED PARTS BREAKDOWN BDV34P A 1 2 3 4 6 7 7 8 9 10 11 Included in Hardware Pack 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 28 29 30 31 3 31 2 31 4 31 1 32 33 32 34 46 5 5 5 35...

Страница 37: ...Natural 1 18 104497 02 SIT Pilot Natural 1 19 104498 01 Thermocouple 1 20 104499 01 Thermopile 1 21 104500 01 Ignitor 1 22 104501 01 Ignitor Bracket 1 23 104502 01 Ignitor Screw 1 24 104503 01 Ignito...

Страница 38: ...ing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED...

Отзывы: