16

Technical Specifications:

WiImportant notes for electricians, in accordance with the 

recommendations

 of OS-

RAM and PHILIPS:

Operation within an electrical circuit that is protected against fault current (fault

current switch):

FFI switch (fault current protection switch - surge protector) - 

30 mA:

maximum 10 LIGHTBRUSH

®

 columns, or

maximum 10 LIGHTBRUSH

®

 modules 1500, or

maximum 10 LIGHTBRUSH

®

 modules 1200, or

maximum 10 LIGHTBRUSH

®

 modules 590, or

maximum 10 LIGHTBRUSH

®

 Cubes.

Explanatory Note: Switches of this type contain „Y“ condensers that work against the

EARTH and consequently reduce fault current.

15

Replacing the Lamps

For economic reasons, we suggest to replace the entire lamp set, even if only one

lamp fails. Use only fluorescent lamps as recommended by the manufacturer. Ensure

that the replacement lamps have the proper length and wattage.

Caution: The lamps come in three colours (red - green - blue), even though the glass

tube itself appears as uniformly white. Please refer to the written specifications printed

on the fluorescent lamps!

Protect yourself against electrical hazard by unplugging the unit before

proceeding!

•

Unlock faulty lamps by turning them 90°, and remove the lamp.

•

Insert the replacement lamp with the appropriate colour into its assigned socket.
Ensure to follow the colour coding (red - green - blue) in the housing and the

specifications printed on the lamp.

•

Lock the replacement lamp in place by turning it 90°.

•

The RGB module is now again ready for use.

LIGHTBRUSH

®

 Master-Module 1500:

Item No. 09916200

Colour Light Module with Control Unit

Type: RGB 1500 / Master

W/H/D: 1546 x 87.5 x 153 mm

Housing: Alu-polished

Weight: 4.1 kg

Power Input Plug 230 Volt, 16 A

Rated Power (Consumption): 180 VA

Power Output: 3200 VA

Features:

Microprocessor for the control of 16.7

million colours, can be controlled and

programmed with (optional) remote

control, 3 1500 mm RGB fluorescent

lamps, 58 W each, data bus connector/

power connection to control slave mo-

dules.

Slave module connection up to 3200 VA,

depending on power supply.

LIGHTBRUSH

®

 Slave-Module 1500:

Item No. 09916300

Colour Light Module 

without

 Control Unit

Type: RGB 1500 / Slave

W/H/D: 1546 x 87.5 x 153 mm

Housing: Alu-polished

Weight: 4.0 kg

Rated Power (Consumption): 180 VA

Features:

3 1500 mm RGB fluorescent lamps, 58

W each, data bus connector/power

connection for the operation of additio-

nal slave columns, 

without

 control unit

and remote control.

Changing the Battery

The universal remote control operates with a 

commercial 9 V block battery

. Open

the battery compartment on the back of the remote control and replace the old

battery with a new one.

Cleaning the Unit

Only the exterior of the unit may be cleaned. For interior cleaning, please contact an

authorized technician or ship the unit to the manufacturer’s factory.

Housing Exterior:

 Clean the exterior with a dry, soft cloth. Do not use cleaning solutions

such as alcohol since this could damage the colour. Do not use compressed air,

sprays or similar means.

Содержание Lightbrush RGB-Cube

Страница 1: ...www derksen de contact our worldwide distribution network Manual Lightbrush rgb Module Lightbrush rgb Cube rgb Module 1500 rgb Module 1200 rgb Module 590 rgb Cube 230 V Version ...

Страница 2: ... Cube Before switching the unit on for the first time please read these instructions and keep them in a safe place Table Of Contents Safety Precautions 2 Installation and Connection 3 Wall Floor or Ceiling Installation 3 Cable Connection and Routing 4 Plug Designations for Data Power Connections 4 LIGHTBRUSH Slave Unit Operation 5 LIGHTBRUSH Infrared Receiver 5 How to Configure Lightbrush for Even...

Страница 3: ...echanical stress Data bus power cables routed over walls or ceilings must be secured at regular intervals of 2 m at least once per meter Cables routed on floors require additional protection against mechanical stress such as being stepped on Cables may be protected with ducts or tubes e g When routing cables always verify that there is no pull on the plugs 4 Installation and Connection Foor Wall o...

Страница 4: ...e suffices to control 30 units You may exceed the maximum number of 30 units if you choose to connect lower power consumption slave modules such as LIGHTBRUSH Slave Module 590 to the LIGHTBRUSH master module If the power consumption of the slave units exceeds a total of 3200 VA and or if more than 30 units are to be connected to the master unit the system can be expanded with a LIGHTBRUSH Intermed...

Страница 5: ...rol all functions at one glance 7 How to Configure Lightbrush for Evenly Distributed Illuminations For the colour illumination of an area certain aspects should be considered during planning installation the depth of the housing the transparency of the front pane the number of modules It is important that the 16 7 million colour shades of the LIGHTBRUSH RGB system have an even and colour homogenou...

Страница 6: ...ng the speed of a running colour change program 1 Preset Programs Factory Settings After you switched the colour light system on you can immediately select one of the preset programs If you want to know how to create your own colour change program please proceed to chapter 2 Select one of the preset programs with the blue buttons on your remote control from 1 to 8 blue button 1 displaying all colo...

Страница 7: ...igned to the yellow buttons of the remote control The programs can be recalled at any time even after a power failure memory function Please follow the instructions below Step 1 Push the button PROGRAMM for approx 3 seconds to enter the programming mode Step 2 Push one of the yellow buttons eg 1 in order to assign your program to it Later you can recall your program by pushing it Step 3 Using the ...

Страница 8: ...th existing DMX standards Certified Quality The supplementary DMX 512 board of DERKSEN Lichttechnik has been certified under the terms of the German technical control board TÜV All components of the LIGHTBRUSH colour light system have the GS mark safety tested and the CE mark compliance with European safety standards Supplementary DMX 512 Board Connections Setting the DIP Switches at the DMX 512 C...

Страница 9: ...e replacement lamp in place by turning it 90 The RGB module is now again ready for use LIGHTBRUSH Master Module 1500 Item No 09916200 Colour Light Module with Control Unit Type RGB 1500 Master W H D 1546 x 87 5 x 153 mm Housing Alu polished Weight 4 1 kg Power Input Plug 230 Volt 16 A Rated Power Consumption 180 VA Power Output 3200 VA Features Microprocessor for the control of 16 7 million colour...

Страница 10: ...nd programmed with optional remote control 3 1200 mm RGB fluorescent lamps 36 W each data bus connector power connection to control slave mo dules Slave module connection up to 3200 VA depending on power supply LIGHTBRUSH Slave Module 1200 Item No 09916500 Colour Light Module without Control Unit Type RGB 1200 Slave W H D 1246 x 87 5 x 153 mm Housing Alu polished Weight 3 5 kg Rated Power Consumpt...

Страница 11: ...sh de LIGHTBRUSH Slave Modules LIGHTBRUSH Slave Columns LIGHTBRUSH Master Module or Column All LIGHTBRUSH Systems can be combined with each other Safety All LIGHTBRUSH Systems have the following test certificates F geprüfte Sicherheit EN 60598 EN 61547 Interference Resistance EN 50081 1 Emission Date of Issue September 2003 Copyright 2003 by DERKSEN Lichttechnik GmbH ...

Отзывы: