Example for Illumination of an Area
(such as a wall area measuring 2000x2000x400 mm in W/H/D):
Power Cabel
MASTER-Module 1500
Data/Power Connection
SLAVE-Module 1500
SLAVE-Module 1500
SLAVE-Module 1500
SLAVE-Module 1500
SLAVE-Module 1500
Data/Power Connection
Data/Power Connection
Data/Power Connection
Data/Power Connection
6
LIGHTBRUSH
®
Slave Unit Operation
Since the LIGHTBRUSH
®
master unit provides the master-slave set-up with power,
the entire unit is switched on and off through the master unit.
Please refer to the
maximum possible number of LIGHTBRUSH
®
Slave Modules
:
The maximum
capacity
of the LIGHTBRUSH
®
master module is 3200 VA. The
maximum number of slave modules for operation with a LIGHTBRUSH
®
master
module depends on total power consumption.
The power consumption of the
slave units must not exceed 3200 VA!
The maximum
control power
of the LIGHTBRUSH
®
master module suffices to
control 30 units. You may exceed the maximum number of 30 units if you choose
to connect lower power consumption slave modules (such as LIGHTBRUSH
®
Slave
Module 590) to the LIGHTBRUSH
®
master module.
If the power consumption of the slave units exceeds a total of 3200 VA and/or if
more than 30 units are to be connected to the master unit, the system can be
expanded with a LIGHTBRUSH
®
Intermediate Amplifier (Item No. 09918600). The
amplifier automatically amplifies the
capacity
and
control power
- for an additional
30 units and a possible additional intermediate amplifier.
Infrared Receiver for LIGHTBRUSH
®
Remote Control
The LIGHTBRUSH
®
master module is equipped with an IR receiver (infrared receiver).
It connects to the side of the master module with a 1.5 m cable. Depending on the
location and position of your set-up, mount the IR receiver so that it allows for easy
remote control pointing. Please ensure that the receivers infrared sensor is not
obstructed. Where possible, the receiver should be installed outside of the boundaries
of your wall/floor/ceiling set-up.
5