![Depaepe Telecom SecurAccess PMR Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/depaepe-telecom/securaccess-pmr/securaccess-pmr_user-manual_2485126048.webp)
Notice SecurAccess PMR
48
Door latch N°1activation
6 0
0 : remote and local activated (factory setting)
1 : remote and local deactivated (Door latch not active)
2: remote activated and local deactivated
3: remote deactivated and local activated
*9
Activation duration door latch N°1
6 1
Enter the number of seconds (from 1 up to 9 seconds).
factory setting = 2 seconds
*9
1
st
access code door latch N°1
6 2
Enter a 4 digits code, (0000 not allowed)
*9
2
nd
access code door latch N°1
6 3
Enter a 4 digits code, (0000 not allowed)
*9
3
rd
access code door latch N°1
6 4
Enter a 4 digits code, (0000 not allowed)
*9
4
th
access code door latch N°1
6 5
Enter a 4 digits code, (0000 not allowed)
*9
5
th
access code door latch N°1
6 6
Enter a 4 digits code, (0000 not allowed)
*9
6
th
access code door latch N°1
6 7
Enter a 4 digits code, (0000 not allowed)
*9
Fast opening door latch N°1
with « 0# » or « 0* »
6 8
0 = deactivation (factory setting) - 1 = activation
*9
Door latch N°1activation
7 0
0 : remote and local activated (factory setting)
1 : remote and local deactivated (Door latch not active)
2: remote activated and local deactivated
3: remote deactivated and local activated
*9
Activation duration door latch N°2
7 1
Enter the number of seconds (from 1 up to 9 seconds).
factory setting = 2 seconds
*9
1
st
access code door latch N°2
7 2
Enter a 4 digits code, (0000 not allowed)
*9
2
nd
access code door latch N°2
7 3
Enter a 4 digits code, (0000 not allowed)
*9
3
rd
access code door latch N°2
7 4
Enter a 4 digits code, (0000 not allowed)
*9
4
th
access code door latch N°2
7 5
Enter a 4 digits code, (0000 not allowed)
*9
5
th
access code door latch N°2
7 6
Enter a 4 digits code, (0000 not allowed)
*9
6
th
access code door latch N°2
7 7
Enter a 4 digits code, (0000 not allowed)
*9
Call barring activation
8 0
0 : Deactivated (no limit)
1 : Activated
(factory setting)
*9
1
er
not allowed first digit
8 1
Digit not allowed.
# if no digit (factory setting)
*9
2
nd
not allowed first digit
8 2
Digit not allowed.
# if no digit (factory setting)
*9
1
er
not allowed first two digits
8 3
The two digits not allowed.
## if no digit (factory setting)
*9
2
nd
not allowed first two digits
8 4
The two digits not allowed.
## if no digit (factory setting)
*9
3
rd
not allowed first two digits
8 5
The two digits not allowed.
## if no digit (factory setting)
*9
4
th
not allowed first two digits
8 6
The two digits not allowed.
## if no digit (factory setting)
*9
Limitation of digits
8 7
Maximum digits allowed from 01 to 29
« ## » no limitation (factory setting)
« 00 » keypad dialing not allowed
*9
Changing the setting code
9 0
Enter the new 4 digits access code twice
note : 0000 = factory setting
*9
switches back the unit to all factory settings
9 1
Four digits access codes
*9
Immediate on Hook
9 9
Close the connection after validation
NB : When storing a number in the memory key , combination of key * # inserts a pause (generally used with a PBX).