Notice SecurAccess PMR
41
5
th
access code door latch N°1
6 6
Enter a 4 digits code, (0000 not allowed)
*9
6
th
access code door latch N°1
6 7
Enter a 4 digits code, (0000 not allowed)
*9
Fast opening door latch N°1
with « 0# » or « 0* »
6 8
0 = deactivation (factory setting) - 1 = activation
*9
Door latch N°1activation
7 0
0 : remote and local activated (factory setting)
1 : remote and local deactivated (Door latch not active)
2: remote activated and local deactivated
3: remote deactivated and local activated
*9
Activation duration door latch N°2
7 1
Enter the number of seconds (from 1 up to 9 seconds).
factory setting = 2 seconds
*9
1
st
access code door latch N°2
7 2
Enter a 4 digits code, (0000 not allowed)
*9
2
nd
access code door latch N°2
7 3
Enter a 4 digits code, (0000 not allowed)
*9
3
rd
access code door latch N°2
7 4
Enter a 4 digits code, (0000 not allowed)
*9
4
th
access code door latch N°2
7 5
Enter a 4 digits code, (0000 not allowed)
*9
5
th
access code door latch N°2
7 6
Enter a 4 digits code, (0000 not allowed)
*9
6
th
access code door latch N°2
7 7
Enter a 4 digits code, (0000 not allowed)
*9
NO: Normally open
NC: Normally close
COM : COMMON
3.12. Time out for no answer
Same as for Chain dialing section (§
Erreur ! Source du renvoi introuvable.
).
This setting is used in the chain dialing settings choice and for the automatic hanging up.
If chain dialing is activated, the SecurAccess will automatically dial the following number stored into
the depressed off-hook/memory button after the selected elapsed time before next call.
If chain dialing is deactivated, the unit will automatically hang up.
Setting to modify
Code
Setting choice
Factory settings are shown in grey
Conf.
Elapsed time before next call
0 8
0 : 10 seconds
1 : 20 seconds
2 : 35 seconds (factory setting)
3 : 1 minute
4 : 5 minutes
*9
3.13. Conversation timer
Talking time can be limited by programming. When this feature is activated and the preset talk time is
elapsed, the SecurAccess will automatically hang up.
Power
supply
Door latch
or
C
NC
NO
Door latch n°1
NO/NC contact R/T
Up to 60 VA and 2A maximum
Door latch n°2
NO/NC contact R/T
Up to 60 VA and 2A maximum
NC
NO
C
NC
NO
C