![Denso AT10Q-SM Скачать руководство пользователя страница 80](http://html1.mh-extra.com/html/denso/at10q-sm/at10q-sm_user-manual_2483281080.webp)
70
(6) Data transmission format common to all interfaces
Items Parameters
Defaults
Refer
to:
Enable
Transmission of code ID mark
Disable
√
Section 9.4
Before prefix
Code ID mark position
After prefix
√
Section 9.4
Type 1 (DENSO1)
√
Type 2 (DENSO2)
Type 3
Type 4
Code ID mark
User-defined
Section 9.4, (5)
Coupling
√
Code ID mark output mode
Separating
Section 9.4, (5)
Enable, in 4 digits
Enable, in 2 digits
Transmission of the number of digits
(not applicable to UPC/EAN codes)
Disable
√
Section 9.4
Enable
Prefix transmission
Disable
√
Enable
Suffix transmission
Disable
√
Section 9.4, (3)
Enable
Scanner ID output
Disable
√
Section 9.4, (2)
Enable
GTIN format conversion
Disable
√
Conversion to 16 digits
√
Conversion to 14 digits
Conversion type from UPC/EAN/
Interleaved 2of5 (14-digit) to GTIN format
Conversion prohibited
Conversion to 14 digits
√
Conversion to 13 digits
Conversion type from RSS (GS1
DataBar)/EAN-128 (GS1-128) in GTIN
format to EAN format
Conversion prohibited
Prefix PI in conversion from UPC/EAN/
Interleaved 2of5 (14-digit) to GTIN format
0 to 9
0
Section 9.5
: Can be changed only with the configuration software.