ENGLISH
26
(“*” indicates the default setting.)
(1)
Auto Cue ON/OFF
* “AutoCue ON”
:
The cue point is detected at a sound level of –54 dB.
“AutoCue OFF”
:
Cue detection is not performed.
(2)
Brake Time: Set the operating time for the BRAKE and PLAT-S modes.
“BK Time S”
:
Short
”BK Time N”
:
Normal
* “BK Time L”
:
Long
(3)
E.O.M
* ”EOM OFF”
:
No end of message is emitted.
“EOM (setting time) sec”
:
Set the end of message time. (10, 15, 20, 30, 60 or 90)
(4)
Pitch Range
“Pitch (setting value) %”
:
Select the pitch adjustment range (16, *10).
(5)
End Monitor
“EndMon (setting time) sec” :
Set the end monitor time (*10, 20, 30 or 60).
(6)
Play Mode: Set the play mode which is set when the power is turned on.
* ”Single”
:
Playback ends at the end of the track.
“Continuous”
:
Playback continues until the end of the disc.
(7)
Time Mode: Set the time mode which is set when the power is turned on.
* ”Elapsed”
:
The elapsed time per track is displayed.
“Remain”
:
The remaining time per track is displayed.
“T.Elapsed”
:
The elapsed time per disc is displayed.
“T.Remain”
:
The remaining time per disc is displayed.
(8)
ASP Mode: Set the mode to which the ASP is set when the power is turned on.
* ”Sampler”
:
Sampler mode
“DigiScratch”
:
Digi-Scratch mode
“Effector”
:
Effector mode
(9)
Auto Close: Set the disc holder auto close mode.
“Close OFF”
:
The disc holders do not close automatically.
“Close (setting time) sec”
:
Set the time from which the disc holder is opened until it is closed automatically (10, *30 or 60).
(10) Sleep Mode: If no operation is performed in the pause or cue mode, the motor stops and the stop mode is set after a specific amount of
time.
“Sleep (setting time) min”
:
Set the time after which the sleep mode is set (*30, 20 or 10).
(11) Digital Out
“DigiOut ON”
:
Digital data is output. (NOTE: The operable functions are limited.)
* ”DigiOut OFF”
:
Digital data is not output.
(12) Program All Clear: Use this to clear all the program data stored in the memory.
q
“Clear OK?” is displayed when the data master knob is pressed when “ProgAll Clr?” is displayed.
w
When the data master knob is pressed again, “PrgAll Clr” is displayed and the data is cleared.
e
“Complete!” is displayed 1 second after the data has been cleared.
(13) Memory All Clear: Use this to clear all the memo data stored in the memory.
q
“Clear OK?” is displayed when the data master knob is pressed when “MemoAllClr?” is displayed.
w
When the data master knob is pressed again, “MemoAllClr” is displayed and the data is cleared.
e
“Complete!” is displayed 1 second after the data has been cleared.
(14) Signal transfer between remote control units: When two remote control units are connected, select the master and slave.
“Copy Master”
:
The memory is copied from this side.
“Copy Slave”
:
The memory is copied to this side.
* ”Copy Off”
:
The memory is not copied.
(15) RC Memo All Copy: Copy the memory data from the master to the slave when two remote control units are connected.
[Slave side]
q
“Slave Mode” is displayed when the data master knob is pressed when “Memo Copy?” is displayed.
w
“Copy OK?” is displayed when the data master knob is pressed again.
e
“Memo Copy” is displayed when the data master knob is pressed again and the data copy standby mode is set.
r
“Complete!” is displayed 1 second after the data transferred from the master side has been copied.
[Master side]
q
“Master Mode” is displayed when the data master knob is pressed when “Memo Copy?” is displayed.
w
“Copy OK?” is displayed when the data master knob is pressed again.
e
“Memo Copy” is displayed when the data master knob is pressed again and the data is transferred. (“Not Connect” flashes if the two
remote control units are not connected or if the slave side is not in the copy standby mode.)
r
“Complete!” is displayed 1 second after the data has been transferred.
(16) Preset Clear: This restores the preset data to the factory default values.
q
“Initial OK?” is displayed when the data master knob is pressed when “Preset Int?” is displayed.
w
“Preset Int” is displayed when the data master knob is pressed again and the data is initialized.
e
“Complete!” is displayed 1 second after initialization is completed.
(3) Detailed Description of Preset Functions