Revision1.30
DCM390 Serial Interface Specification
Date 25.Apr.’06
26 page of 40
D&M
2.6.8 STOP command
This command stops playback, recording, fast forward and rewind.
1) Command format
Byte/bit
7
6
5
4
3
2
1
0
0 STX
(0x02)
1
Command code (‘A’)
2 Reserve
(0x00)
3 Reserve
(0x00)
4 Reserve
(0x00)
5 Reserve
(0x00)
6 ETX
(0x03)
7 BCCH
(high-level)
8 BCCL
(low-level)
Table 34. STOP command
2) Answer format
Byte/bit
7
6
5
4
3
2
1
0
0 STX
(0x02)
1
Reply code (‘A’)
2
Answer code (Table 3)
3 ETX
(0x03)
4 BCCH
(high-level)
5 BCCL
(low-level)
Table 35.STOP answer
3) Special conditions
- The answer code returns “Command OK”, when mecha status data is Stop.