2.6.14 Track Num Entry command
This command designates the truck that should program playback truck, in the case of program mode or in
the case of a direct mode.
1) Command format
Byte/bit
7
6
5
4
3
2
1
0
0 STX
(0x02)
1
Command code (‘G’)
2 Reserve
(0x00)
3
Track number 100 digits
4
Track number 10 digits
5
Track number 1 digits
6 ETX
(0x03)
7 BCCH
(high-level)
8 BCCL
(low-level)
Table 47. Play Num Set command
2) Answer format
Byte/bit
7
6
5
4
3
2
1
0
0 STX
(0x02)
1
Reply code (‘G’)
2
Answer code (Table 3)
3 ETX
(0x03)
4 BCCH
(high-level)
5 BCCL
(low-level)
Table 48. Play Num Set answer
3) Special condition