30
q
Number of heat run is display
(1) Press the
9
button while the error is displayed.
(2) No. heat runs is displayed for 5
seconds, the error display reappears
.
(XXXX : No. of heat run repetitions)
w
The track no. and time when the error occurred is displayed.
(1) Press the
8
button while the error is displayed.
(2) The track no. and time when the error occurred is displayed for 5 seconds, then error display reappears.
4. COLD START (INITIALIZE)
(1) AC is turned on while pressing the
5
and
9
button same time on this unit..
(2) The system is reset, and once this is completed the unit is set to the normal mode.
DIMMER : 100%
DISC/USB : DISC
REMOTE/BROWSE : REMOTE
(3) The laser current initial value and laser accumulated on time is not cleared
5. EEPROM TEST MODE
(1) AC is turned on while simultaneously pressing POWER and DISC/USB button.
(2)
TEST start
(turn off the
POWER LED
).
(3) After EEPROM TEST, in the case of OK, LED lights to the green.
(4) After EEPROM TEST, in the case of NG, LED lights to the red.
(5) Mode is cancelled with POWER OFF.
6. AUTO STANDBY TEST MODE
(1) AC is turned on while pressing the
5
and
8
button same time on this unit.(Entering the Service mode)
(2)
The AUTO STANDBY timer is set to 4 minutes.
CD
XXXX
CD
01Tr
01:47
INITIALIZE
AUTO STANDBY
TEST MODE
Содержание DCD-F109
Страница 32: ...32 Personal notes...
Страница 57: ...57 PACKING VIEW 6 1 4 5 3 2 6 9 11 10 8 9 10 5 7 5 6 5 8 5 1 5 5 5 5 2 5 3 5 4 s...
Страница 63: ...63 TMP92CD28AFG IC15 39 DCD 710AE TMP92CD28AFG IC15...
Страница 67: ...67 TC94A92FG IC17 43 DCD 710AE TC94A92FG IC17...
Страница 75: ...75 2 FL DISPLAY V F D 16 ST 103GINK FLT500 PIN CONNECTION GRID ASSIGNMENT 1 43...
Страница 76: ...76 GRID ASSIGNMENT...
Страница 77: ...77...