1.10. About the error code
See the table below for error codes and details of faults when the firmware is updated through USB memory.
Error
Code
USB Update Error Display
Details of Error code
Coping strategies
01
C o n n e c t i o n
f a i l
0 1
Unable to detect USB.
Disconnect and connect the USB mem-
ory.
02
F i l e s N o t F o u n d
0 2
No FirmwareFile in USB.
Make sure that the FirmwareFile is in
the USB memory.
03
N o t M a t c h F i r m
0 3
Firmware File in USB for unsup-
ported Model name/area.
Check the supported Model name/area
for the Firmware File.
04
C o n n e c t i o n
f a i l
0 4
Failed to obtain entire Firmware
information.
Start the USB Update again.
05
C o n n e c t i o n
f a i l
0 5
Time Out while obtaining entire
Firmware information.
Start the USB Update again.
08
C o n n e c t i o n
f a i l
0 8
Error notification received while
requesting Firmware Info.
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error dis-
play, press and hold the "Power opera-
tion" button for five seconds.
09
C o n n e c t i o n
f a i l
0 9
Time Out while obtaining Firm-
ware information.
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error dis-
play, press and hold the "Power opera-
tion" button for five seconds.
0A
C o n n e c t i o n
f a i l
0 A
Unable to detect USB for Firm-
ware Download.
Disconnect and connect the USB mem-
ory.
0B
F i l e s N o t F o u n d
0 B
No Firmware File for Firmware
Download.
Disconnect and connect the USB mem-
ory.
0D
C o n n e c t i o n
f a i l
0 D
Received value with invalid Pack-
age Version.
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error dis-
play, press and hold the "Power opera-
tion" button for five seconds.
10
M a i n
* * * m i n
U p d a t i n g
f a i l
1 0
No Update Packet received from
CX870 / CY920 (Time Out).
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error dis-
play, press and hold the "Power opera-
tion" button for five seconds.
11
M a i n
* * * m i n
U p d a t i n g
f a i l
1 1
Abnormal data in Update Packet
received from CX870 / CY920
(CRCError).
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error dis-
play, press and hold the "Power opera-
tion" button for five seconds.
12
M a i n
* * * m i n
U p d a t i n g
f a i l
1 2
Abnormal data in Update Packet
received from CX870 / CY920
(PacketNoError).
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error dis-
play, press and hold the "Power opera-
tion" button for five seconds.
13
M a i n
* * * m i n
E r a s e
f a i l
1 3
Block Erase failed before rewriting
Main.
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error dis-
play, press and hold the "Power opera-
tion" button for five seconds.
84
Содержание AVR-X4100
Страница 8: ...Personal notes 8...
Страница 25: ...Personal notes 25...
Страница 192: ...AK5358BET DIGITAL IC306 AK5358BET Pin Function 192...
Страница 199: ...NJW1194A INPUT IC484 BLOCK DIAGRAM 199...
Страница 200: ...2 FL DISPLAY FLD 17 BT 40GINK FRONT FL601 PIN CONNECTION GRID ASSIGNMENT Y2 q 200...
Страница 201: ...ANODE CONNECTION 201...