ADJUSTMENT
Adjusting Idling Current
1. Preparation
(1) Prepare a DV voltmeter.
(2) Place the unit in normal usage conditions, away from highly ventilated areas such as next to an air conditioning ma-
chine or electric fan.
The set requires an ambient temperature of 15℃ ~30℃ and standard humidity.
(3) Settings of This Unit
• POWER (Power source switch)
STANDBY
• SPEAKER (Speaker terminal)
No load
( Do not connect equipment such as speakers or dummy resistors. )
2. Adjustment Procedure
(1) Remove the top cover and turn VR714, VR724, VR734, VR744, VR754, VR764, VR774 of the AMP PCB as far anticlock-
wise(
c
) as possible.
(2) Connect the DC Voltmeter test points.
FRONT-Lch
: CN715
FRONT-Rch
: CN725
CENTER ch
: CN735
SURROUND-Lch
: CN745
SURROUND-Rch
: CN755
SURROUND-BACK Lch
: CN765
SURROUND-BACK Rch
: CN775
(3) Connect the power cord to an outlet. Next, press the power button to turn on the power.
(4) Set this unit as follows.
MASTER VOLUME
: "---" anticlockwise (
c
min.)
SPEAKER (Speaker terminal)
: No load
( Do not connect equipment such as speakers or dummy resistors. )
MODE
: MCH STEREO
FUNCTION
: DVD
(5) Turn VR714 clockwise (
x
) and adjust the voltage of the test point to "
6.5mV ± 0.5mV DC
" within 2 minutes.
(6) 10 minutes after the preliminary adjustment, turn VR714 and set the voltage as "
8.0mV ± 0.5mV DC
".
(7) Adjust the variable resistance of each channel using the same method.
CN775
CN765
CN755
CN745
CN725
CN715
VR774
VR764
VR724
VR754
CN735
VR734
VR714
VR744
FL-CH
SL-CH
C-CH
SR-CH
FR-CH
SBL-CH
SBR-CH
F Lch
S Lch
F Rch
C ch
S Rch
S Back Lch
S Back Rch
AMP UNIT
DC Voltmeter
97
Содержание AVR-X4100
Страница 8: ...Personal notes 8...
Страница 25: ...Personal notes 25...
Страница 192: ...AK5358BET DIGITAL IC306 AK5358BET Pin Function 192...
Страница 199: ...NJW1194A INPUT IC484 BLOCK DIAGRAM 199...
Страница 200: ...2 FL DISPLAY FLD 17 BT 40GINK FRONT FL601 PIN CONNECTION GRID ASSIGNMENT Y2 q 200...
Страница 201: ...ANODE CONNECTION 201...