4. Technical Description
The drum lifter has 3 wheelbase options and two lifting options:
Servo Type
FL 8-K
FL 12-K
FL 16-K F
FL 16-K H
Wheelbase
narrow
wide
wide
wide
Overall height
(mm)
1540
1540
2130
2130
Lifting range (mm)
120 - 520
0 - 520
0 - 1170
0 - 1170
Lifting equipment
with hydraulic pump
with hydraulic pump
with hydraulic pump
with cable
winch
Oil fill volume
(litres)
0.8
0.8
1.0
-
The Servo Drum lifter is constructed as follows:
Stable frame with lifting mast
-
Adjustable drum gripper
-
Hydraulic pump with lifting cylinder or crank handle with cable winch -
-
2 fixed castors and 2 swivel castors (for the Ex version in electrically conductive design).
5. Setting up and initial operation
Drum lifter with hydraulic pump:
Before using the drum lifter for the first time, loosen the oil screw on the hydraulic
cylinder and raise the lifter with a load on board so that the air is removed from the
hydraulic system. Afterwards tighten the oil screw again. This method can also be
used for removing any air bubbles in the hydraulic system in the future.
If the oil screw is replaced with a screw with a hole (possibly included in the
delivery), the hydraulic system is permanently bled.
Adjust the adapter plate to suit the drum gripper
By changing the adapter plate the drum lifter can be adjusted to suit various starting heights and so the "no
load lift distance" (the amount the lifter is raised before the drum is lifted) can be reduced.
To do this, loosen the safety screws above the attachment holes (A or B) and then hang the adapter plate on
the frame at a different height. Now set the new attachment position using the safety screws.
Lifting height and gripping position
Adapter plate attachment position
Regularly check the safety screws and if necessary tighten them.
6. Technical data
Maximum load: 300 kg
Permitted operating temperature / ambient temperature: -10°C to 40°C.
A
Safety screw
B