5.0  CARTRIDGE REPLACEMENT PROCEDURE

  THE PURIFIER IS A PRESSURE CONTAINING DE-

VICE. DEPRESSURIZE BEFORE REPLACING ANY CARTRIDGE.  

5.1  Filter Cartridge No. 0713-2-1

1.  Close inlet and outlet isolation ball valves. Depressurize 

the filter by slowly opening manual drain as shown.

2.  Unscrew the metal collar holding the filter bowl to the 

head and remove the filter bowl and collar. Clean the filter 

bowl.

3.  Unscrew the old filter cartridge and discard. Also  discard 

the small o-ring that seals the filter cartridge top cap to 

the filter assembly head.

4.  Insert small replacement o-ring on top of new replace-

ment filter cartridge and screw replacement filter 

cartridge into filter assembly head. It is only necessary to 

finger tighten the filter cartridge into position to insure 

the seal. DO NOT WRENCH TIGHTEN.

  THE FILTER CARTRIDGE SHOULD NEVER BE 

HANDLED BY ITS OUTSIDE FOAM COVER. DAMAGE CAN RE-
SULT. WHEN INSTALLING A REPLACEMENT FILTER CARTRIDGE, IT 
SHOULD BE HELD BY THE BOTTOM END CAP ONLY. (See Drawing)

5.  Replace filter bowl and screw collar onto filter assembly 

head.

5.2  Convertor Cartridge P/N 3154050

1.  Disconnect spring which holds convertor case to bracket.
2.  Using hands or strap wrench, unscrew case collar and 

lower case assembly vertically downward to clear used 

cartridge. If insufficient space is available to clear car-

tridge, allow case to rest on floor and proceed to next 

step.

3.  Unscrew used cartridge and remove cartridge and bowl 

assembly.

4.  Remove 5/16" nut and sleeve seal assembly from top of 

used cartridge.

5.  Open new cartridge bag. Replacement cartridges are 

furnished in a dated vapor barrier bag. (NOTE: DO NOT 

OPEN VAPOR BARRIER BAG UNTIL READY TO INSTALL NEW 

CARTRIDGE.)

6.  Insert new 1-7/8" I.D. x 2" O.D. o-ring in o-ring groove on 

top cap of new cartridge.

7.  Fasten sleeve seal assembly to top of new cartridge. 

Check to see that o-ring is properly seated in top cap o-

ring groove.

8.  Insert new 1-3/4" I.D. x 1-7/8" O.D. o-ring in sleeve seal.
9.  Check convertor case to see that cartridge support spring 

is positioned in the bottom of the case.

10.  Screw cartridge into head and hand tighten. Install case 

and hand tighten collar. (If bottom edge of mounting 

bracket is less than 45 inches above floor, place cartridge 

in case and position both below head before installing 

cartridge.) Hand tightening of cartridge and case is 

adequate to insure seals. DO NOT USE WRENCH TO 

TIGHTEN CARTRIDGE.

11.  Reconnect convertor case retaining spring.
12.  Prior to placing air purifier into service, observe purifier 

warning labels. Do not open purifier outlet isolation valve 

if upper indicator band is yellow. See Section 3.0.

NOTE:

 DO NOT USE A WRENCH TO TIGHTEN THIS EQUIPMENT.

OPEN ( TO RIGHT )

KNURLED FITTING

Head

O-ring

1-3/4” X 1-7/8”

Sleeve Seal

Assembly

Converter

Case

Hex Nut

5/16” - 18

O-ring

1-7/8” x 2”

Cartridge

No. 0719-1

Spring

Содержание PBA-12

Страница 1: ...BREATHING AIR PURIFIER Model PBA 12 FOR M NO 3227497 R EVI S ION 02 2012 R EAD AN D U N D E R STAN D TH I S MAN UAL PR IOR TO OPE RATI NG OR S E RVICI NG TH I S PROD UCT I N STR UCTION MAN UAL ...

Страница 2: ...Contents GENERAL SAFETY INFORMATION 1 1 0 INSTALLATION 2 2 0 DESIGN LIMITATIONS 2 3 0 OPERATION 3 4 0 MAINTENANCE 4 5 0 CARTRIDGE REPLACEMENT PROCEDURE 5 6 0 GENERAL INFORMATION 6 PARTS LIST 6 WARRANTY ...

Страница 3: ...atalyst used to eliminate carbon monoxide This indicator is not a carbon monoxide detecting device A compressor high temperature alarm or carbon monoxide alarm or both should be provided If a compressor high temperature alarm only is used frequent testing for carbon monoxide concentration should be conducted 4 LIMIT TO CARBON MONOXIDE REMOVAL This equipment is provided with a catalyst which can co...

Страница 4: ...On questionable applications the factory should be consulted prior to installation or operation TABLE 1 Recommended maximum flow rates at various operating pressures Inlet Pressure psig kgf cm2 20 1 4 40 2 8 60 4 2 100 7 0 150 10 6 200 14 0 Flow Rate scfm m3 hr 3 0 5 1 4 8 8 2 6 5 11 0 10 0 17 0 14 4 24 5 18 7 31 8 SHIPPING WEIGHT 34 lbs 15 4 kg 1 6 3 4 2 5 7 8 205 8 524 213 16 71 12 305 321 8 822...

Страница 5: ... gaseous hydrocarbons normally adsorbable by activated carbon B Before and during operation it is necessary to make certain checks to insure satisfactory performance 1 Check to see that lines downstream of the purifier are clean and free of materials which could show up at the point of use of the air 2 Check to see that the filter and convertor are installed level This is necessary to insure adequ...

Страница 6: ...tridge life at other conditions as follows Step 1 From Table 3 find Maximum Theoretical Life MTL in standard cubic feet scf that model 1901 can handle at the pressure and dew point temperature at the inlet to the purifier Step 2 If the inlet air is less than 100 saturated dew point temperature is less than sensible temperature adjust MTL for level of saturation Refer to Table 4 and find the Satura...

Страница 7: ...ilable to clear car tridge allow case to rest on floor and proceed to next step 3 Unscrew used cartridge and remove cartridge and bowl assembly 4 Remove 5 16 nut and sleeve seal assembly from top of used cartridge 5 Open new cartridge bag Replacement cartridges are furnished in a dated vapor barrier bag NOTE DO NOT OPEN VAPOR BARRIER BAG UNTIL READY TO INSTALL NEW CARTRIDGE 6 Insert new 1 7 8 I D ...

Страница 8: ... entering and contaminating car tridges 2 Replacement convertor cartridge should not be exposed to moisture or high humidity Do not unseal vapor bag until immediately before installation and operation 3 Replacement of the convertor cartridge which is con sumable is much more frequent hours of use than the filter cartridge months of use 4 Consult factory for questionable applications or when in dou...

Страница 9: ......

Страница 10: ......

Страница 11: ...d under warranty shall be warranted for the unexpired portion of the warranty applying to the original product The foregoing is the exclusive remedy of any buyer of the manufacturer s product The maximum damages liability of the manufacturer is the original purchase price of the product or part THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER WRITTEN ORAL OR STATUTOR...

Отзывы: