1.0 INSTALLATION
1.1 Location
See schematic drawing, Figure 1. The purifier is designed
specifically to treat compressed air for supplied breathing air
systems. To insure its functional operation, proper installation
is vital.
NOTE:
Inlet and outlet isolation valves, drain and bleed valves
should be kept in closed position at all times when purifier is
not in operation.
Figure 1
in (mm)
1.3 Cartridge
A. Purifier is shipped with convertor cartridge separately car-
toned. This cartridge must be installed prior to operation.
See Section 5.2 for installation instructions.
2.0 DESIGN LIMITATIONS
A. Flow - nominal 10 scfm at 100 psig (7.03 kg/cm
2
)
B. Maximum working pressure - 200 psig (14.06 kg/cm
2
)
standard
C. Maximum operating temperature - 120°F (48.9°C)
D. Chemical attack - compressed air does not normally
contain contaminants which will adversely affect this
purifier. However, aromatic and chlorinated hydrocarbons,
acids, bases and certain other chemicals can attack parts
of the filter assemblies and result in personal injury.
On questionable applications, the factory should be
consulted prior to installation or operation.
TABLE 1
Recommended maximum flow rates at various operating
pressures.
Inlet Pressure
psig
kgf/cm
2
20
(1.4)
40
(2.8)
60
(4.2)
100
(7.0)
150
(10.6)
200
(14.0)
Flow Rate
scfm
m
3
/hr
3.0
5.1
4.8
8.2
6.5
11.0
10.0
17.0
14.4
24.5
18.7
31.8
SHIPPING
WEIGHT
34 lbs. (15.4 kg)
1
6
3
4
2
5
7
8
20
5
/
8
(524)
2
13
/
16
(71)
12 (305)
32
1
/
8
(822)
6 (152)
Minimum Clearance
Required for Service
Air Outlet
1/2 - 14 NPT
Air Inlet
1/2 - 14 NPT
6
1
/
2
(165)
3
19
/
32
(91)
5
1
/
2
(140)
OPEN
OPEN
1. Filter
2. Convertor
3. Indicator
4. Isolation Valves
5. Mounting Bracket
6. Drain Valve
7. Indicator Bleed & Check Valve
8. Differential Pressure Gauge
NOTE:
Remove plastic protectors from isolation valves,
indicator bleed valve, filter and convertor drain valves,
and convertor head.
1.2 Mounting
A. Install so inlet and outlet connections are horizontal
and so that all cartridges are in a vertical position. Tipping
of cartridges from the vertical orientation can impede
drainage and/or reduce their efficiency. Allow a minimum
of 6" (152 mm) below the bottom edge of the convertor
case for cartridge replacement.
B. Bolt mounting bracket to wall or other support member
by means of (4) 5/16" fasteners.