5
Switch Setting Descriptions:
The DIP Switches can only be changed when AC drive is in a stopped mode.
Indicates the position of the switch (ON/OFF).
DIP
Switch
Switch
Name
Switch Setting
Parameter Descriptions
Maximum Output Frequency
V/F Curve
ON
1 2 3 4 5 6 7
50Hz
100%
50Hz
f
1
ON
1 2 3 4 5 6 7
60Hz
100%
60Hz
f
ON
1 2 3 4 5 6 7
100Hz
100%
50Hz 100Hz
f
2
Max.
Output
Frequency
ON
1 2 3 4 5 6 7
120Hz
100%
60Hz 120Hz
f
ON
1 2 3 4 5 6 7
Reverse enable
3
Reverse
Inhibit
ON
1 2 3 4 5 6 7
Reverse disable
ON
1 2 3 4 5 6 7
Low torque output
4
Torque
Setting
ON
1 2 3 4 5 6 7
High torque output
ON
1 2 3 4 5 6 7
Applicable for 40/100W motor
5
Electronic
Thermal
Setting
ON
1 2 3 4 5 6 7
Applicable for 25/60W motor
ON
1 2 3 4 5 6 7
Operation command controlled by potentiometer.
6
Operation
Command
Source
Select (1)
ON
1 2 3 4 5 6 7
Operation command controlled by external terminal
ON
1 2 3 4 5 6 7
Operation command controlled by external terminal
(can be monitored by communication mode)
7
Operation
Command
Source
Select (2)
ON
1 2 3 4 5 6 7
Switch 7 is ON, indicates the communication mode is
enabled; switches 1 to 6 are address settings.