CLEANING INSTRUCTIONS
CLEAN the outside of the chrome plated flushometer with a damp cloth.
CAUTION:
MOST Tub & Tile fixture cleaners contain ACIDS. DO NOT WIPE the cloth used to clean ceramic fixtures over the flushometer
as it will remove the chrome plating and leave a discoloured surface.
1
4
3
2
Fig. 11
A
8
7
Detail “A”
-
+
5
7
8
6
8
7
Detail “B”
INADVERTENT FLUSHING
(see Figure 11)
1.
Check for the presence of a mirror or reflective surface across from the flushometer.
2.
Cover the reflective surface by standing in front or with paper, if this resolves the inadvertent flushing then:
3.
Follow the instructions
“Making Adjustments to the Electronic Features”
on page 5, to reduce the sensor range until inadvertent flushing
is resolved. If this does not resolve the inadvertent flushing proceed to step 4.
4.
Remove the two cover screws (1), metal cover (2), cap (3) and electronic override button (4).
5.
Raise the board (7) up out of the box to get access to the adjustment screw (6).
6.
Using a 1/16” hex key (5) turn the adjustment screw (6) located on the top of the board (7). Turn the screw counter-clockwise
to
decrease the angle (A) or clockwise to increase the angle, see “Detail A”.
CAUTION: DO NOT
let the board (7) touch the plastic housing (8), as shown in “Detail B”. Maximum screw rotation is approximately 2-1/2
turns.
7.
If the cover of the board becomes detached, rotate the screw clockwise until it can be reattached and repeat step 6, taking care to
ensure you do not over adjust the screw.