background image

212385 Rev. A

www. s p e c s e l e c t . c o m

Page 7

BATTERY STRENGTH INDICATOR & BATTERY REPLACEMENT

TO CHECK BATTERY STRENGTH:

1. 

During Operation Mode - press and hold down the electronic override button for approximately 10 seconds.

2. 

DO NOT RELEASE BUTTON WHEN SOLID BLUE LIGHT IS PRESENT - KEEP HOLDING DOWN. 

3. 

After 10 seconds, the battery strength will be displayed via the red lights. The more lights that are present, the more life the batteries 

have. See Figure 8.

4. 

When you are satisfied with the strength indication, release the electronic override button to return to Operation mode.

TO REPLACE BATTERIES:

1. 

Remove the two cover screws and lift off metal cover, see Figure 9.

2. 

Hold case/cover securely with one hand and open hinged lid of the battery compartment in the 

back of the unit.

3. 

Pull the battery holder out and insert new set of four “AA” batteries into battery holder. (Use the +/- 

signs on the batteries and the +/- signs on the battery holder for correct positioning.) 

Note:

 Do not use a metal screwdriver to remove snap from battery holder.

4. 

Install the refreshed battery holder back into the electronic housing. (When the new batteries are 

installed and connected, an initial ascending and descending red light sequence will occur.)

5. 

Close the battery compartment lid ensuring wires are neatly tucked into compartment and are not 

pinched between case and cover. Test the electronic override button. Blue light flashes once when 

override is activated.

6. 

Place the metal cover back onto flushometer and replace the two cover screws. DO NOT 

OVERTIGHTEN. Flushometer is now ready for use. 

NOTE:

 All previously adjusted settings will be retained when batteries are changed.

1.  Start-Up:

 When batteries are first inserted, there is an initial ascending and descending red light 

sequence that will occur.

2.  Electronic Override Button in Operating Mode: 

Blue light flashes once when Electronic 

Override Button is activated.

3.  Low Battery Level Indicator: 

One RED light flashes every 15 seconds, indicating approximately 

5,000 flushes remain from when RED light first started flashing.

Fig. 8

BATTERY STRENGTH INDICATION

VERY HEALTHY   

- 5 RED LIGHTS

HEALTHY 

 

- 4 RED LIGHTS

AVERAGE 

 

- 3 RED LIGHTS

LOW AVERAGE   

- 2 RED LIGHTS

REPLACE BATTERIES  - 1 RED LIGHT

Fig. 10

Fig. 9

Содержание TECK II 81T201BT

Страница 1: ... 16 18 20 19 13 14 15 28 28 27 9c 1 Electronic Exposed TECK II Flush Valves with H2Optics Record model number 81T2__ 1__ __A __ __ __ __ Alternate Flush Volumes leave blank if not applicable 6 6 L litre 1 6 gal fixed flush W C only 13 13 L 3 4 gal flush W C Retrofit Kits only 48 4 8 L 1 27 gal fixed flush W C only 19 1 9 L 0 5 gal fixed flush Urinal only 05 0 5 L 0 125 gal fixed flush Urinal only ...

Страница 2: ...5 060082A Adjustable Tail O Ring Package 20 pkg 16 060504A S S Wall Flange Cover Tube 17 061142A 061143A Electronic Water Closet Repair Kit for 3rd Generation E FV Electronic Urinal Repair Kit for 3rd Generation E FV 18 060697A 060694A 060764A 1 Copper Sweat Inlet Adaptor Copper Sweat Inlet Adaptor FIP Inlet Adaptor 19 060843A 060844A 060859A Retrofit Check Stem Unit Capnut Button Complete Seat Wa...

Страница 3: ...42A 060507A UR Adjustable 1 9L 0 5 gal 061346A W C Fixed 4 8L 1 27 gal 061344A 060507A 062025A 061323A 6 0L 1 6 gal 061345A W C Adjustable 13L 3 4 gal 061352A 060507A 6 0L 1 6 gal 061169A 060507A 062025A NOTE Must use all noted components listed in Table 1 to ensure correct flush volumes Fixed models have epoxy in the adjustment screw WaterSense compliant when paired with a WaterSense fixture rate...

Страница 4: ...NOT remove the four screws 7b that hold down the cap solenoid assembly 6b You will now see the clear electronic compartment with a grey cover Now take hold of the compartment and very carefully slowly lift the compartment about 1 4 and turn it 180 The sensor eye should now be on the other side Gently push the compartment back down aligning the two screw holes on the clear case with the screw holes...

Страница 5: ... is off INSTALLATION INSTRUCTIONS BATTERY FLUSHOMETER for Hardwire skip to Step 3 STEP 1 Install battery flushometer to fixture Open inlet stop STEP 2 Follow instructions on yellow static label Figure 4 Note The batteries are already installed and the product is in hibernation mode waiting to be activated After you remove the yellow label you must push the electronic override button three times wi...

Страница 6: ...e electronic override button to advance to the next adjustment feature A blue and red light will be present This mode is currently inactive and is designed for any future options To advance to the 24 Hour Flush press and hold down electronic override button for 5 seconds until the solid blue light is present Release electronic override button you are now in 24 Hour Flush configuration For Urinals ...

Страница 7: ...nap from battery holder 4 Install the refreshed battery holder back into the electronic housing When the new batteries are installed and connected an initial ascending and descending red light sequence will occur 5 Close the battery compartment lid ensuring wires are neatly tucked into compartment and are not pinched between case and cover Test the electronic override button Blue light flashes onc...

Страница 8: ... water closet flush valve requires a minimum water supply of 1 or larger depending on a number of different factors including water pressure PSI available pipe size and length of pipe run number of fixtures per washroom and per building fixture type fixture usage factor elevation of valve above the water main etc We strongly recommend that pipe size calculations be done to insure proper water supp...

Страница 9: ... Making Adjustments to the Electronic Features on page 5 to reduce the sensor range until inadvertent flushing is resolved If this does not resolve the inadvertent flushing proceed to step 4 4 Remove the two cover screws 1 metal cover 2 cap 3 and electronic override button 4 5 Raise the board 7 up out of the box to get access to the adjustment screw 6 6 Using a 1 16 hex key 5 turn the adjustment s...

Страница 10: ...NCIDENTAL AND CONSEQUENTIAL SPECIAL INDIRECT OR PUNITIVE DAMAGES CONNECTED THEREWITH ARE EXCLUDED AND WILL NOT BE PAID BY DELTA FAUCET Some states provinces do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and ...

Отзывы: