101
Installation and Operation Manual for Inverter RPI M50A_12s V1 EU EN 2017-03-09
8 Settings
8.4.8 EPO (External power-off )
Overview
This function allows you to define the relay contacts for the exter-
nal power-off (EPO) as being normally closed or normally open
contacts.
Setting options
Parameter
Description
Setting range
EPO
Defines how the relay functions for the external
power-off (EPO).
Normal Open
|
Normal Closed
Menu item path
Main Menu > Install Settings > EPO
Setting the external power-off
E-Today: 0kWh
Power: 0W
Status: On Grid
10.Sep 2014 15:32
1.
If the default information is displayed, press any button to open the main menu.
Otherwise, press the
EXIT
button repeatedly until the main menu is displayed.
Inverter Info.
General Settings
Install Settings
Active/Reactive Pwr
FRT
2.
Use the
and
buttons to select the
Install Settings
entry and then press the
ENT
button.
Password 0 * * *
energy production.
Adj. would affect
Warning:
3.
This function is protected with password 5555.
Use the
and
buttons to set the individual numerals.
Press the
ENT
button to confirm a number.
Grid Settings
DC Injection
Dry Contact
RCMU: ON
EPO: Normal Close
4.
Use the buttons
and
to select the entry
EPO
and press the
ENT
button.
→ The shape of the arrow changes , the value can be changed.
The currently set value is displayed after the entry.
Grid Settings
DC Injection
Dry Contact
RCMU: ON
EPO: Normal Close
5.
Use the
and
buttons to configure the value and then press the
ENT
button.