TECHNICAL DATASHEET

 

PJB Open Frame Power Supply 

24V 100W 1 Phase / PJB-24V100W

□□

A

 

 

 

  

All parameters are specified at 25°C ambient and AC input unless otherwise indicated.

 

  www.DeltaPSU.com (October 2020, Rev. 03)  

 

14

 

Others 

Conformal Coating 

The Protective Coating Technology 

Delta Electronics Group has designed the perfect dipping technique which penetrates everywhere including under 

device, and prevents leakage. The conformal coating dipping can be applied to PCBs or circuit board. The coating 

preserves the performance of precision electronic primarily by preventing ionizable contaminants such as salt 

from reaching circuit nodes, where the material slumps around sharp edges. This can be a problem especially in 

highly conversing atmosphere. 

 

 

PFC – Norm EN 61000-3-2 

Line Current Harmonic content 

Typically, the input current waveform is not sinusodial due to the periodical peak charging of the input capacitor. 

In industrial environment, complying with EN 61000-3-2 is only necessary under special conditions. Complying to 

this standard can have some technical drawbacks, such as lower efficiency as well as some commercial aspects 

such as higher purchasing costs. Frequently, the user does not profit from fulfilling this standard, therefore, it is 

important to know whether it is mandatory to meet this standard for a specific application.

 

 

Attention 

Delta provides all information in the datasheets on an “AS IS” basis and does not offer any kind of warranty through the information for 

using the product. In the event of any discrepancy between the information in the catalog and datasheets, the datasheets shall prevail 

(please refer to www.DeltaPSU.com for the latest datasheets information). Delta shall have no liability of indemnification for any claim or 

action arising from any error for the provided information in the datasheets. Customer shall take its responsibility for evaluation of using 

the product before placing an order with Delta. 
Delta reserves the right to make changes to the information described in the datasheets without notice. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание PJB-24V100WA

Страница 1: ...rush current and conformal coating on the PCBAs to provide protection against dust and chemical pollutants The built in active PFC provides PF 0 97 and fulfills Harmonic Current Emission according to...

Страница 2: ...g at 24V 8 60A Power Boost for 10 seconds at 24V refer to the details in the Functions section Output Power 103 2W continuously operating at 24V 206 4W Power Boost for 10 seconds at 24V refer to the d...

Страница 3: ...Degree 2 Protections Overvoltage 27 6 33 6V Latch Mode Overload Overcurrent 220 of rated load current Hiccup Mode Non Latching Auto Recovery Over Temperature Latch Mode Short Circuit Hiccup Mode Non...

Страница 4: ...4 Level 3 Criteria A1 2kV Surge IEC 61000 4 5 Level 3 Criteria A1 Common Mode2 2kV Differential Mode3 1kV Conducted IEC 61000 4 6 Level 3 Criteria A1 150kHz 80MHz 10Vrms Power Frequency Magnetic Fiel...

Страница 5: ...Connector 3 VR 4 Remote ON OFF JST B2B XH A 5 Chassis Dimensions Open Frame L x W x D 155 x 62 x 33 5 mm 6 10 x 2 44 x 1 32 inch L Frame L x W x D 185 x 72 x 45 mm 7 28 x 2 83 x 1 77 inch Notes Dimens...

Страница 6: ...Rev 03 6 Item Device Description 1 Input Connector 2 Output Connector 3 VR 4 Remote ON OFF JST B2B XH A 5 Cover 6 Chassis Enclosed L x W x D 185 x 72 x 45 mm 7 28 x 2 83 x 1 77 inch Notes Dimensions a...

Страница 7: ...nce at all sides from other components and equipments Please insert an insulation sheet between the system and product if the safety distance is less than 4mm 0 16 inch Use flexible cable stranded or...

Страница 8: ...ting for Mounting Orientation A B 40 C de rate power by 2 5 C De rating for Mounting Orientation C 35 C de rate power by 2 C De rating for Mounting Orientation D E 30 C de rate power by 2 C De rating...

Страница 9: ...or be damaged when the power supply is continuously used outside the shaded region refer to the graphs shown above 2 If the output capacity is not reduced when the surrounding air temperature is more...

Страница 10: ...t Current mA Output ON Output OFF 1k 5 12 5 0 0 5 20 Max Notes 1 Remote ON OFF circuits are isolated from input output and PE 2 Please check if the polarity of the wire connector is the same as the ex...

Страница 11: ...te set value after the input voltage is applied Rise Time The time required for the output voltage to change from 10 to 90 of its final steady state set value Hold up Time Time between the collapse of...

Страница 12: ...Power Boost to be longer than the specified duty cycle calculation this may cause damage to the PSU Power Boost is the reserve power available constantly that allows reliable startup to support sudde...

Страница 13: ...ustration in the OLP OCP section on this page The power supply will return to normal operation after the short circuit is removed Overload Overcurrent Protections Auto Recovery The power supply s Over...

Страница 14: ...nvironment complying with EN 61000 3 2 is only necessary under special conditions Complying to this standard can have some technical drawbacks such as lower efficiency as well as some commercial aspec...

Отзывы: