10
Output Load De-rating VS. Input Voltage
Functional Manual
Remote ON/OFF Function
You can remotely control the power supply unit to turn
ON/OFF by using an external DC source. Follow the DC
power source voltage and current limiting defined in the
table below.
Built-in Resistor R
i
(ohm)
Voltage Between
RC+ and RC- (V)
Input Current (mA)
Output ON
Output OFF
1k
5-12.5
0-0.5
20 Max
Notes
1. Remote ON/OFF circuits are isolated from input, output and PE.
2. Please check if the polarity of the wire connector is the same as the external DC source. If not, the power would not turn on and the
internal components may be damaged.
3. You do not need an external resistance R
O
for current limit while the output voltage of external DC source is within the range of 5-
12.5V. If the output voltage exceeds 12.5V, please use the following equation for the value of current limit resistance R
O
.
𝑅𝑅
𝑂𝑂
=
𝑉𝑉𝑉𝑉𝑉𝑉 −
(3.5 + 0.006
𝑅𝑅
𝑖𝑖
)
0.006
No output power de-rating for the input voltage
range from 90Vac to 264Vac
Fig.1.5 De-rating for Mounting Orientation A to F
< 90Vac de-rate power by 2% / V