background image

LYTE II DIN Rail Power Supply 

DRL-480W series / DRL-

V480W1EN

 

PRELIMINARY DATASHEET- For product review purpose only. The specs are subjected to change.

 

 

 

 

 

  

All parameters are specified at 25°C ambient and AC input unless otherwise indicated.

 

  www.DeltaPSU.com (August 2021, Rev. X00) 

 

2

 

Specifications 

 

Model Number 

DRL-24V480W1EN

 

DRL-48V480W1EN 

 

Input Ratings / Characteristics 

 

Nominal Input Voltage 

100-240 Vac 

Input Voltage Range 

90-264 Vac  

Nominal Input Frequency 

50-60 Hz 

Input Frequency  Range 

47-63 Hz 

Input Current 

4.6 A typ. @ 115 Vac, 2.3 A typ. @ 230 Vac 

Efficiency at 100% Load 

93.0% typ. @ 230 Vac 

93.5% typ. @ 230 Vac 

Average Efficiency 
(25%, 50%, 75%, 100%) 

91.5% typ. @ 115 Vac 

91.5% typ. @ 115 Vac 

No Load Power Consumption 

0.75 W max @ 115 Vac & 230 Vac  

0.75 W max @ 115 Vac & 230 Vac 

Max Inrush Current (Cold Start) 

40 A typ. @ 230 Vac

 

Power Factor at 100% Load  

> 0.96 @ 115 Vac & > 0.93 @ 230 Vac 

Leakage Current 

< 1.5 mA @ 240 Vac 

 

 

Output Ratings / Characteristics

*2

 

 

Nominal Output Voltage 

 24 Vdc 

48 Vdc 

Factory Set Point Tolerance 

 24 Vdc ± 1% 

48 Vdc ± 1% 

Output Voltage Adjustment Range 

 24-28 Vdc 

48-55 Vdc 

Output Current 

 0-20.0 A 

0-10.0 A 

Output Power 

 480 W max 

Line Regulation 

 ± 0.5% @ 115 Vac & 230 Vac 

Load Regulation 

 ± 0.5% 

± 0.5% 

PARD

*3

 (20 MHz) 

 < 150 mVpp @ 0°C to +70°C 

< 450 mVpp @ -30°C to 0°C 

< 200 mVpp @ 0°C to +70°C 
< 600 mVpp @ -30°C to 0°C 

Rise Time 

 30 ms typ. @ 115 Vac & 230Vac 

Start-up Time 

 500 ms typ. @ 115 Vac & 230 Vac (24 V) 

800 ms typ. @ 115 Vac & 230 Vac (48 V)  

Hold-up Time 

 25 ms typ. @ 115 Vac & 230 Vac (100% load)  

Dynamic Response  
(Overshoot & Undershoot O/P Voltage) 

 ± 10% @ 115 Vac & 230 Vac input, 10-100% load  

(Slew Rate: 2.5 

A/μS, 50% duty cycle @ 5

 Hz & 10 kHz) 

Start-up with Capacitive Loads 

 8,000 µF Max  

 

3,000 µF Max 

*2 For power will be de-rating from 40°C to 70°C @ 115Vac & 50°C to 70°C @ 230 Vac, and Vin < 100 Vac, see Engineering Data power de-rating information. 

*3 PARD is measured with an AC coupling mode, 5cm wires, and in parallel to end terminal with 0.1 

μF ceramic capacitor & 47

 

μF electrolytic capacitor.

 

PSU need to burn in 

around 5 minutes w

hen AMB ≤ 0

°C 

 

 

Содержание LYTE II DRL-24V480W1EN

Страница 1: ...applications without compromising on quality and reliability The convection cooled LYTE II series will operate between 30 C to 70 C with full rated power available from 30 C to 50 C at 230 Vac The ov...

Страница 2: ...Vac Output Ratings Characteristics 2 Nominal Output Voltage 24 Vdc 48 Vdc Factory Set Point Tolerance 24 Vdc 1 48 Vdc 1 Output Voltage Adjustment Range 24 28 Vdc 48 55 Vdc Output Current 0 20 0 A 0 10...

Страница 3: ...er De rating Temperature 40 C de rate power by 1 67 C 115 Vac 50 C de rate power by 2 5 C 230 Vac Input Voltage 100Vac de rate power by 1 Vac Operating Humidity 20 to 90 RH Non Condensing Operating Al...

Страница 4: ...O P 100 load Ta 25 C Expected Cap Life Time 10 years 230 Vac 50 load 40 C Safety Standards Directives Electrical Safety CB scheme TUV Bauart UL cUL BSMI EAC IEC 62368 1 IEC 60950 1 IEC 61010 1 2 201 E...

Страница 5: ...ectrical Fast Transient Burst IEC 61000 4 4 Level 3 Criteria A1 2 kV Surge IEC 61000 4 5 Level 4 Criteria A1 Common Mode4 4 kV Differential Mode5 2 kV Conducted IEC 61000 4 6 Level 3 Criteria A1 150 k...

Страница 6: ...iagram DRL V480W1EN EMI Filter PFC Converter Inrush current limit Filter DC DC Converter Output Rectifier Filter Over Temperature Protection PWM Control Over Power Protection Photo Coupler Feedback Co...

Страница 7: ...ons L x W x D 123 6 x 56 x 116 8 mm 4 87 x 1 57 x 4 60 inch Unless otherwise specified tolerance of dimension are 0 5 mm AWG Wire Table Current Rating for PVC Wire 6 AWG 52 5 A 8 AWG 37 5 A 10 AWG 29...

Страница 8: ...e output capacity is not reduced when the surrounding air temperature 50 C the device will run into Over Temperature Protection When activated power supply will latch off until the surrounding air tem...

Страница 9: ...l out the power supply unit PSU from the rail Safety Instructions Vertical Mounting ALWAYS switch mains of input power OFF before connecting and disconnecting the input voltage to the unit If mains ar...

Страница 10: ...d for the output voltage to change from 10 to 90 of its final steady state set value Hold up Time Time between the collapse of the AC input voltage and the output falling to 95 of its steady state set...

Страница 11: ...lso provides protection against short circuits When a short circuit is applied the output current will operate in Hiccup mode The power supply will return to normal operation after the short circuit i...

Страница 12: ...no liability of indemnification for any claim or action arising from any error for the provided information in the datasheets Customer shall take its responsibility for evaluation of using the produc...

Отзывы: