background image

LYTE II DIN Rail Power Supply 

DRL-480W series / DRL-

V480W1EN

 

PRELIMINARY DATASHEET- For product review purpose only. The specs are subjected to change.

 

 

 

 

 

  

All parameters are specified at 25°C ambient and AC input unless otherwise indicated.

 

  www.DeltaPSU.com (August 2021, Rev. X00) 

 

8

 

Engineering Data 

Output Load De-rating VS Surrounding Air Temperature 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output Load De-rating VS Input Voltage 

  

 

 

 

0

10

20

30

40

50

60

70

80

90

100

110

-30

-20

-10

0

10

20

30

40

50

60

70

Per

cen

tag

of

 M

ax 

Lo

ad

(%

)

Surrounding Air Temerature (

°

C)

0

10

20

30

40

50

60

70

80

90

100

110

90

100

264

Lo

ad

 (%

)

Input Voltage (Vac)

 

No output power de-rating for the input 

voltage from 100 Vac to 264 Vac 

Note 

 

1.  Power supply components may degrade, or 

be damaged, when the power supply is 

continuously used outside the shaded region, 

refer to the graph shown in Fig. 1. 

2.  The PSU will be bouncing and start up time 

will not exceed 5 s when ambient temperature 
at 

30°C. 

3.  If the output capacity is not reduced when the 

surrounding air temperature >  50°C, the 

device will run into  Over Temperature 

Protection. When activated, power supply will 

latch off, until the surrounding air temperature 

is lowered or the load is reduced as far as 

necessary to keep the device in working 

condition, and require removal/re-application 

of input AC voltage in order to restart.

 

4.  In order for the device to function in the 

manner intended, it is also necessary to keep 

a safety distance as recommended in the 

safety instructions while the device is in 

operation.

 

5.  Depending on the surrounding air temperature 

and output load delivered by the power 

supply, the device can be very hot! 

6.  Need to consider power de-rating if 

surrounding Air Temperature large than 40°C 

at 115 Vac and 50°C at 230 Vac. 

7.

 

If the device has to be mounted in any other 

orientation, please contact 

[email protected] 

for more details.

 

 

Fig. 1  De-rating for Vertical Mounting Orientation 

> 40°C de-rate power by 1.67 % / °C @ 115 Vac 

> 50°C de-rate power by 2.5 % / °C @ 230 Vac 

Fig. 2  De-rating for AC Input Voltage 

< 100 Vac de-rate power by 1 % / Vac 

 

 230 Vac              - - - 115 Vac

 

Содержание LYTE II DRL-24V480W1EN

Страница 1: ...applications without compromising on quality and reliability The convection cooled LYTE II series will operate between 30 C to 70 C with full rated power available from 30 C to 50 C at 230 Vac The ov...

Страница 2: ...Vac Output Ratings Characteristics 2 Nominal Output Voltage 24 Vdc 48 Vdc Factory Set Point Tolerance 24 Vdc 1 48 Vdc 1 Output Voltage Adjustment Range 24 28 Vdc 48 55 Vdc Output Current 0 20 0 A 0 10...

Страница 3: ...er De rating Temperature 40 C de rate power by 1 67 C 115 Vac 50 C de rate power by 2 5 C 230 Vac Input Voltage 100Vac de rate power by 1 Vac Operating Humidity 20 to 90 RH Non Condensing Operating Al...

Страница 4: ...O P 100 load Ta 25 C Expected Cap Life Time 10 years 230 Vac 50 load 40 C Safety Standards Directives Electrical Safety CB scheme TUV Bauart UL cUL BSMI EAC IEC 62368 1 IEC 60950 1 IEC 61010 1 2 201 E...

Страница 5: ...ectrical Fast Transient Burst IEC 61000 4 4 Level 3 Criteria A1 2 kV Surge IEC 61000 4 5 Level 4 Criteria A1 Common Mode4 4 kV Differential Mode5 2 kV Conducted IEC 61000 4 6 Level 3 Criteria A1 150 k...

Страница 6: ...iagram DRL V480W1EN EMI Filter PFC Converter Inrush current limit Filter DC DC Converter Output Rectifier Filter Over Temperature Protection PWM Control Over Power Protection Photo Coupler Feedback Co...

Страница 7: ...ons L x W x D 123 6 x 56 x 116 8 mm 4 87 x 1 57 x 4 60 inch Unless otherwise specified tolerance of dimension are 0 5 mm AWG Wire Table Current Rating for PVC Wire 6 AWG 52 5 A 8 AWG 37 5 A 10 AWG 29...

Страница 8: ...e output capacity is not reduced when the surrounding air temperature 50 C the device will run into Over Temperature Protection When activated power supply will latch off until the surrounding air tem...

Страница 9: ...l out the power supply unit PSU from the rail Safety Instructions Vertical Mounting ALWAYS switch mains of input power OFF before connecting and disconnecting the input voltage to the unit If mains ar...

Страница 10: ...d for the output voltage to change from 10 to 90 of its final steady state set value Hold up Time Time between the collapse of the AC input voltage and the output falling to 95 of its steady state set...

Страница 11: ...lso provides protection against short circuits When a short circuit is applied the output current will operate in Hiccup mode The power supply will return to normal operation after the short circuit i...

Страница 12: ...no liability of indemnification for any claim or action arising from any error for the provided information in the datasheets Customer shall take its responsibility for evaluation of using the produc...

Отзывы: