background image

LYTE II DIN Rail Power Supply 

DRL-480W series / DRL-

V480W1EN

 

PRELIMINARY DATASHEET- For product review purpose only. The specs are subjected to change.

 

 

 

 

 

  

All parameters are specified at 25°C ambient and AC input unless otherwise indicated.

 

  www.DeltaPSU.com (August 2021, Rev. X00) 

 

4

 

Model Number 

DRL-24V480W1EN

 

DRL-48V480W1EN 

 

Reliability Data 

 

MTBF 

Telcordia 

SR-332 

> 700,000 hrs

 

I/P: 115

 

Vac & 230

 

Vac, O/P: 100% load, Ta: 25°C 

Expected Cap Life Time   

10 years (230

 

Vac, 50% load @ 40°C)  

 

 

Safety Standards / Directives 

 

Electrical Safety 

CB scheme 

TUV Bauart 

UL/cUL 

BSMI 

EAC 

IEC 62368-1, IEC 60950-1, IEC 61010-1/-2-201 
EN 62368-1, EN/BS 61010-1/-2-201 
UL 62368-1, UL 61010-1/-2-201 
CNS14336-1 
TP TC 004/2011 

CE 

  In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU 

UKCA 

  In conformance with Electrical Equipment (Safety) Regulations 2016 and Electromagnetic 

Compatibility Regulations 2016 

Galvanic Isolation 

Input to 

Output  3.0

 

KVac 

 

Input to 

Ground  2.0

 

KVac 

 

Output to 

Ground  1.0

 

KVac 

 

 

 

Содержание LYTE II DRL-24V480W1EN

Страница 1: ...applications without compromising on quality and reliability The convection cooled LYTE II series will operate between 30 C to 70 C with full rated power available from 30 C to 50 C at 230 Vac The ov...

Страница 2: ...Vac Output Ratings Characteristics 2 Nominal Output Voltage 24 Vdc 48 Vdc Factory Set Point Tolerance 24 Vdc 1 48 Vdc 1 Output Voltage Adjustment Range 24 28 Vdc 48 55 Vdc Output Current 0 20 0 A 0 10...

Страница 3: ...er De rating Temperature 40 C de rate power by 1 67 C 115 Vac 50 C de rate power by 2 5 C 230 Vac Input Voltage 100Vac de rate power by 1 Vac Operating Humidity 20 to 90 RH Non Condensing Operating Al...

Страница 4: ...O P 100 load Ta 25 C Expected Cap Life Time 10 years 230 Vac 50 load 40 C Safety Standards Directives Electrical Safety CB scheme TUV Bauart UL cUL BSMI EAC IEC 62368 1 IEC 60950 1 IEC 61010 1 2 201 E...

Страница 5: ...ectrical Fast Transient Burst IEC 61000 4 4 Level 3 Criteria A1 2 kV Surge IEC 61000 4 5 Level 4 Criteria A1 Common Mode4 4 kV Differential Mode5 2 kV Conducted IEC 61000 4 6 Level 3 Criteria A1 150 k...

Страница 6: ...iagram DRL V480W1EN EMI Filter PFC Converter Inrush current limit Filter DC DC Converter Output Rectifier Filter Over Temperature Protection PWM Control Over Power Protection Photo Coupler Feedback Co...

Страница 7: ...ons L x W x D 123 6 x 56 x 116 8 mm 4 87 x 1 57 x 4 60 inch Unless otherwise specified tolerance of dimension are 0 5 mm AWG Wire Table Current Rating for PVC Wire 6 AWG 52 5 A 8 AWG 37 5 A 10 AWG 29...

Страница 8: ...e output capacity is not reduced when the surrounding air temperature 50 C the device will run into Over Temperature Protection When activated power supply will latch off until the surrounding air tem...

Страница 9: ...l out the power supply unit PSU from the rail Safety Instructions Vertical Mounting ALWAYS switch mains of input power OFF before connecting and disconnecting the input voltage to the unit If mains ar...

Страница 10: ...d for the output voltage to change from 10 to 90 of its final steady state set value Hold up Time Time between the collapse of the AC input voltage and the output falling to 95 of its steady state set...

Страница 11: ...lso provides protection against short circuits When a short circuit is applied the output current will operate in Hiccup mode The power supply will return to normal operation after the short circuit i...

Страница 12: ...no liability of indemnification for any claim or action arising from any error for the provided information in the datasheets Customer shall take its responsibility for evaluation of using the produc...