background image

DX-3001 Series Industrial Cloud Router

 

3-38 

_3 

 

 

 

 

 

 

Description

 

Default 

Add A 

Telephone 

Number 

ID 

The maximum allow the 10 phone numbers 

N/A 

Name 

Set up a name for phone number, The name shall be composed of 

N/A 

Содержание DX-3001 Series

Страница 1: ...cs Korea Inc 1511 Byucksan Digital Valley 6 cha Gasan dong Geumcheon gu Seoul Korea 153 704 TEL 82 2 515 5303 FAX 82 2 515 5302 Delta Electronics Int l S Pte Ltd 4 Kaki Bukit Ave 1 05 05 Singapore 417939 TEL 65 6747 5155 FAX 65 6744 9228 Delta Electronics India Pvt Ltd Plot No 43 Sector 35 HSIIDC Gurgaon PIN 122001 Haryana India TEL 91 124 4874900 FAX 91 124 4874945 Americas Delta Products Corpora...

Страница 2: ...ckage Checklist 1 7 Chapter 2 User Interface 2 1 Web based GUI Configuration 2 2 2 1 1 System Connection 2 2 2 1 2 Default IP Address Account Password 2 2 2 1 3 Local Network Setups 2 2 2 1 4 Logging in 2 4 2 2 DIADevice 2 5 2 2 1 Device Connection and Detection 2 6 2 2 2 Network Setting 2 8 2 2 3 Bind Device 2 11 2 2 4 Open Device Webpage 2 13 Chapter 3 Functions 3 1 Status 3 2 3 1 1 Network Stat...

Страница 3: ... Firmware Upgrade 3 31 3 4 7 Backup Restore 3 32 3 4 8 System Reboot 3 32 3 4 9 Scheduled Jobs 3 33 3 4 9 1 Add A New Job 3 33 3 4 9 2 Export Job List 3 34 3 4 9 3 Import Job List 3 34 3 4 10 Network Diagnosis 3 34 3 4 11 Privilege Management 3 35 3 4 12 Event Management 3 38 3 4 13 Register Management 3 42 3 5 Cloud Service 3 43 3 5 1 Cloud Service 3 43 3 5 2 Proxy Setting 3 48 3 5 3 Secure Tunne...

Страница 4: ... Select a Suitable Firmware Version 5 2 5 2 Instructions for DIACloud 5 2 5 2 1 Register and Login 5 2 5 2 2 Home 5 4 5 2 3 Devices 5 6 5 2 4 Alarm 5 16 5 2 5 Secure Tunnels 5 17 5 2 6 Sub Users 5 19 5 2 7 Logs 5 22 5 2 8 Orders 5 23 5 2 9 Profile 5 24 Chapter 6 DIACloud 6 1 Introduction to DIACloud APP 6 2 6 1 1 Select a Suitable Firmware Version 6 2 6 1 2 DIACloud APP Installation 6 2 6 2 DIAClo...

Страница 5: ...Introduction Table of Contents 1 1 Product Overview 1 4 1 1 1 Network Design 1 5 1 1 2 Features 1 5 1 1 3 Front Panel Ports and LEDs 1 6 1 1 4 Top Panel 1 6 1 1 5 Bottom Panel 1 7 1 1 6 Dimension 1 8 1 2 Package Checklist 1 8 ...

Страница 6: ...ause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which t...

Страница 7: ...duct In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures EN 55032 Class A Warning Class A ITE is a category of all other ITE which satisfies the class A ITE limits but not the class B ITE limits The following warning shall be included in the instructions for use Warning This equipment is compliant with Class A of EN 5...

Страница 8: ...roduct is equipped with multiple application interfaces including Ethernet interface RS232 serial interface and RS485 serial interface and thus can satisfy the user s various different application demands The product supports DIACloud platform services and by this platform convenient and efficient point to point connection with the router safe and reliable data transmission remote device managemen...

Страница 9: ...GE 850 900 1800 1900 MHz Authentication Protocols CHAP and PAP Access Point Name APN gateway Automatic redial when connection is broken Dual SIM card slots support auto switching between the cellular operators WAN port access mode static IP DHCP client Provide Dual Port RS232 RS485 and LAN Port Interfaces for Different Application Demands Built in a Watchdog Timer to Ensure System Stability Built ...

Страница 10: ...6 _1 Network Fault Detection and Diagnosis DIACloud Service to Secure Point to point Data Transmission to Manage Device Configurations Piece by Piece or in Batch and to Upgrade Firmware Remotely 1 1 3 Front Panel Ports and LEDs 1 1 4 Top Panel ...

Страница 11: ...ith the router powered on press the Reset button and release the button right away Reset to Factory Defaults With the router powered on press and hold the Reset button for 3 6 seconds and then release the button Reset can only be done when the device is running properly With the router powered on press and hold the Reset button until all the LEDs go out except the Power LED Then release the button...

Страница 12: ...e contents The package should contain the following items DX 3001H9 Industrial 3G Cloud Router x 1 Quick Installation Guide x 1 SMA Antenna 300cm x 1 Notice Verify that nothing is missing from the DX 3001H9 package by using the check list above If any item is found missing or damaged please contact your local sales representative for support ...

Страница 13: ...ration 2 2 2 1 1 System Connection 2 2 2 1 2 Default IP Address Account Password 2 2 2 1 3 Local Network Setups 2 2 2 1 4 Logging in 2 4 2 2 DIADevice 2 5 2 2 1 Device Connection and Detection 2 6 2 2 2 Network Setting 2 8 2 2 3 Bind Device 2 11 2 2 4 Open Device Webpage 2 13 ...

Страница 14: ...nd the router is done you will need to set the network configruration for your computer There are 2 methods for the setting we prefer you use the first one Obtain an IP address automatically by using the router as a DHCP server 1 Open Network Connections by clicking the Start button and then clicking Control Panel 2 Under Network and Sharing Center click View network connections 3 Right click the ...

Страница 15: ...face 2 3 2_ 5 Click Obtain DNS server address automatically and then click OK to get a DNS server address automatically using DHCP Set up the IP address manually The IP address of the computer should be in the same subnet as the router s ...

Страница 16: ...ess to 192 168 1 10 and the default gateway to 192 168 1 1 For DNS the usable DNS address can be selected or the address can also be set to 192 168 1 1 2 1 4 Logging in 1 Open your Internet Explorer browser and input LAN IP address Default is 192 168 1 1 or the router s domain name www diadevice com in the search bar and then press Enter 2 You ll be prompted with the log in page Input the user nam...

Страница 17: ...erver for the computer 2 2 DIADevice DIADevice is a tool for quickly configuring network devices Users simply connect the DX device to the PC through the network cable This tool can be used to quickly and easily configure the network setting of the device and complete the device binding DIACloud cloud account The DIADevice software is included in the latest DIACom software package From the officia...

Страница 18: ...ply and connect the device to the PC using a network cable Plug the network cable connected to the Internet into the WAN port of the device 2 Run DIADevice software click Detect button 3 After DIACom detects the device it will automatically go to the login page and the user needs to enter login password on the login page ...

Страница 19: ...Interface 2 7 2_ 4 After passing the authentication the device information page is displayed including the basic device information Device Name S N firmware LAN IP address network status WAN information and cloud service information ...

Страница 20: ...llows you to quickly configure your network in two steps 1 Click Network Setting 2 You can setup the connection priority here and then it will guide you to config each the connection parameter page base on the priority what you setup 3 WAN setting page and Proxy setting page if need ...

Страница 21: ...Chapter 2 Introduction to User Interface 2 9 2_ 4 Cellular setting page ...

Страница 22: ...DX 3001 Series Industrial Cloud Router 2 10 _2 5 After the device successfully connected to the Internet the connection was successful ...

Страница 23: ..._ 2 2 3 Bind Device This feature allows you to quickly bind your device to the DIAcloud in three steps 1 Click Bind Device 2 Enter the DIAcloud account number and password and click Next 3 After binding configuration is configured click Bind to bind ...

Страница 24: ... is successfully bound to the cloud the following screen will appear Notice If the device has been bound to the cloud account you need to switch to another cloud account binding you only need to repeat 1 3 steps and then enter the new cloud account you need to bind ...

Страница 25: ...r 2 Introduction to User Interface 2 13 2_ 2 2 4 Open Device Webpage Click open device webpage button the browser will open the device settings page the user can set the parameters of RS232 485 configuration ...

Страница 26: ...rewall 3 16 3 3 1 MAC Filter 3 16 3 4 System 3 17 3 4 1 User Management 3 17 3 4 2 Time Zone Configurations 3 18 3 4 3 RS232 3 18 3 4 4 RS485 3 23 3 4 5 Modbus TCP 3 29 3 4 6 Firmware Upgrade 3 32 3 4 7 Backup Restore 3 33 3 4 8 System Reboot 3 33 3 4 9 Scheduled Jobs 3 34 3 4 9 1 Add A New Job 3 34 3 4 9 2 Export Job List 3 35 3 4 9 3 Import Job List 3 35 3 4 10 Network Diagnosis 3 35 3 4 11 Priv...

Страница 27: ...DX 3001 Series Industrial Cloud Router 3 2 3 5 1 Cloud Service 3 44 3 5 2 Proxy Setting 3 49 3 5 3 Secure Tunnel Firewall 3 50 3 5 4 Cloud Log 3 51 ...

Страница 28: ... connection type WAN mode IP Address Network Mask Gateway Address primary DNS and Secondary DNS When router connects to internet by Cellular the status includes the Operator APN User Name Password MCC MNC Signal Strength authorization mode dial up number Online Duration IP Address Network Mask Gateway Address primary DNS and Secondary DNS LAN includes the LAN IP Address and connection status of 4 ...

Страница 29: ...and Resource Usage Information Basic Information Item Description Device Type Model type of the router Device Name Name of the router the default is DX3001 _ the last four digits of Mac address S N Serial number of the router Version Information Item Description Hardware Version Version number of the hardware currently used on the router ...

Страница 30: ...ource Usage Information Item Description CPU Usage The CPU usage of current router Total Memory The total memory on the router Memory Used The memory currently used on the router Memory Usage The current ratio of the router usage 3 1 3 Local Log This page shows logs of the router including the System log Warning lot and the Debug log You can use the buttons on the right hand side to refresh clear ...

Страница 31: ...nformation of the devices connected to the router including the IP Address Host Name MAC Address 3 2 Network You can set up networks configuration including the connection priority Cellular network WAN and LAN Configurations 3 2 1 Connection This page is used for setting up the connection priority Router provide 3 links to connect to Internet include cellular network 1 2 and WAN user can appoint t...

Страница 32: ...ion Set up the LAN network mask Disabled Auto Detect Check if the connection is dropped or not via PING Disabled Target Address 1 Set the first IP domain of the server that program will do a ping testing N A Target Address 1 Set the second IP domain of the server that program will do a ping testing N A Dial Failure To Restart Enable or disable the function if the dial failure will be in the defaul...

Страница 33: ...ction is available it will automatically switch to the WAN connection to reduce the traffic loss of 3G Disable Wan Check Interval Set the interval for detecting WAN connection status 10s 3 2 2 Cellular Link1 This page is used for setting up the Cellular Network for SIM1 including the Operator User Name Password APN Authorization Mode Dial Up Number Dial Up Mode Redial Interval Redial Times Max Idl...

Страница 34: ...et up accordingly Others users can set up the operator manually AUTO User Name This name is provided by the operator When Auto is selected the system will set the name up automatically and users cannot change the setting N A Password This password is provided by the operator When Auto is selected the system will set the password up automatically and users cannot change the setting N A APN Access P...

Страница 35: ...en the system fails to connect This will only be executed when the option Always online or On demand connection is selected 30 Redial Times Set up the maximum redial time 0 indicating infinity This will only be executed when the option Always online or On demand connection is selected 0 Max Idle Time Set up the maximum idle time When the idle time exceeds the set value the router will disconnect a...

Страница 36: ...de Redial Interval Redial Times Max Idle Time Connection Check Interval Connection Check Times and MTU Description Default Operator Select Auto or Others for the Operator from the dropdown list Auto the system will detect the operator from the inserted SIM card and set up accordingly Others users can set up the operator manually AUTO User Name This name is provided by the operator When Auto is sel...

Страница 37: ...a disconnection is detected the router will redial to connect automatically On demand connection redial when connection to the internet is on demand Manual connection users dial to connect and when it fails to connect it will not redial Always online Redial Interval Set up the time to redial when the system fails to connect This will only be executed when the option Always online or On demand conn...

Страница 38: ...ue in the Redial Times 5 MTU Maximum Transmission Unit is the largest packet that can be transmitted over packet based networks 1492 3 2 4 WAN This page is used for setting up the WAN including the IP address network mask gateway and DNS Description Default WAN Mode Your device can connect to the internet via the WAN port with a Dynamic IP or Static IP Static IP Manually set up the IP address Dyna...

Страница 39: ...configurable when the mode is set to Static 0 0 0 0 Gateway Address Set up the gateway address It s configurable when the mode is set to Static 0 0 0 0 MTU Maximum Transmission Unit is the largest packet that can be transmitted over packet based networks 1500 Retrieve DNS Address By The Retrieve DNS Address Method is the same as the WAN Connection Mode that you have set You can apply to different ...

Страница 40: ...your network you can specify the IP address range and lease time for the clients on your network Once the DX router have bound the DIACloud and enabled the DIACloud DHCP the DHCP in DX router will be disabled automatically Enable Address Lease Time To set up the address lease time so that a client doesn t hold an IP address indefinitely It allows for a mechanism to gracefully reuse DHCP addresses ...

Страница 41: ...e will increase about 15Mbit in 24 hours Disable 3 3 Firewall 3 3 1 MAC Filter This page is used for setting up the MAC Filter including configuring the MAC Address Device Name and Status MAC Filter is used to block particular MAC address from the local network Select Enable Disable to activate deactivate this functionality Click the Add A MAC Address to block the MAC Address After clicking the Ad...

Страница 42: ...nt 3 4 1 User Management You can change the administrator password and set up web page session timeout here The password must be a combination of 5 to 12 characters numbers and or underline symbols Description Default Old Password Input the original password admin New Password Input the new password you d like to use The password length should be 5 12 digits and is composed of lowercase letters up...

Страница 43: ...escription Default The current time of device Here shows the current time of your device N A Local PC Time Here shows the current time of your local PC which connect to the device Set Local PC Time Set the router time same as the PC time N A Time Zone Setting Select the operating time zone of your device GMT 12 00 GMT 13 00 N A 3 4 3 RS232 RS232 Recommended Standard 232 is a telecommunication stan...

Страница 44: ...Chapter 3 Introduction to Functions 3 19 _3 ...

Страница 45: ...DX 3001 Series Industrial Cloud Router 3 20 _3 ...

Страница 46: ... PLC to perform the read write tasks on the open register of the Router Serial Server TCP Client This mode is suitable for the router connect to serial server by TCP protocol as a client Serial Server UDP Client This mode is suitable for the router connect to serial server by UDP protocol as a client Close Disable this functionality Close Parameters of COM Baud Rate Set up the baud rate for the se...

Страница 47: ... Timeout Set up the timeout timer from 200ms to 5000ms If the set value is out of range it will be automatically changed to its maximum or minimum value 1000ms Serial Server TCP Client TCP Alive Check Time Set up the keep alive time of TCP connection Range from 0 to 99 minutes 0 Never disconnect the connection 1 99 Disconnect the TCP connection after the idle time meet the set value 7 Destination ...

Страница 48: ...Port defaults are 6001 6004 and configurable Local listen port Set up the local port 15000 Packing length Set up the threshold for sending packets Range from 0 to 1024 bytes 0 means it is immediately sent once data coming 0 Force transmit Set up the how long it will wait before it send packets mandatory Range from 0 to 65536 millisecond 0 means never send packets mandatory 0 3 4 4 RS485 RS485 Reco...

Страница 49: ...DX 3001 Series Industrial Cloud Router 3 24 _3 ...

Страница 50: ...Chapter 3 Introduction to Functions 3 25 _3 ...

Страница 51: ...er of the router Master mode This mode is suitable for the router to perform the read write tasks on the open register of the PLC Serial Server TCP Client This mode is suitable for the router connect to serial server by TCP protocol as a client Serial Server UDP Client This mode is suitable for the router connect to serial server by UDP protocol as a client Close Disable this functionality Close P...

Страница 52: ...y changed to its maximum or minimum value 1000ms Master Mode Scan Interval Set up the time for scan interval ranging from 20ms to 60000ms 30000ms Read Write Set up the access permissions for the mapped register address Read only The device regular read data from appointed registers in the slave but will not update the data to the slave Write only The device update the data to the slave when the re...

Страница 53: ...ting Address decimal Set up the device starting address decimal input range is from 2048 to 4095 specifies that the match must start at the beginning of a Device Starting Address N A Length 1 123 Here displays the number of the continuous address followed by the default mapped address N A Add Mappings Click the button to add mappings the data mapping can be set to 200 N A Edit Click an item of reg...

Страница 54: ...ry 0 Serial Server UDP Client Destination IP address and port Set the IP segment and port of the serial server Up to 4 segments can be configured and there are at most 99 addresses in each segment Port defaults are 6001 6004 and configurable Local listen port Set up the local port 15000 Packing length Set up the threshold for sending packets Range from 0 to 1024 bytes 0 means it is immediately sen...

Страница 55: ... the open registers in router It supports up to 32 connections from client Modbus TCP Client Master for router to read write the open registers in a PLC It supports to connect to 4 different servers at most OFF Modbus TCP Client Server IP Set up the IP address of a PLC in the Modbus TCP Client mode N A Server Port Set up the server port of a PLC in the Modbus TCP Client mode 502 ...

Страница 56: ...slave when the registers values was changed but will not read the data from the slave Read write The device regular read data from appointed registers in the slave will update the data to the slave when the registers values is changed Read Write Slave ID Set up the corresponding slave communication port The value is between 1 and 247 N A Controller Device types Delta PLC Delta DVP AH AS series PLC...

Страница 57: ... that the match must start at the beginning of a Device Starting Address N A Length 1 123 Here displays the number of the continuous address followed by the default mapped address N A Operation Delete the selected mapped address N A Add Mappings Click the button to add mappings the data mapping can be set to 200 N A Edit Click to select the records from the mapped address to edit N A Operation The...

Страница 58: ...evice configurations on your computer N A Restore Click Browse to select the backup file and then click Restore to restore the configurations The device configuration will be restored to the previous version and the device will reboot after the restoring is done N A Restore To Factory Default Click Restore To Factory Default to reset the configurations to the factory defaults The device will reboo...

Страница 59: ... new scheduled job Description Default Job Name Set up a name for your scheduled job The name shall be composed of letters numbers and underline starting with a letter or number The maximum string length is 32 bytes N A Enable Select Enable to activate this functionality Enable Recurring Job The scheduled job can be done Once Every day Every week or Every month And the specific time can be further...

Страница 60: ... Cellular Network Restart device 3 4 9 2 Export Job List Click Export Job List to export the scheduled jobs for future usage 3 4 9 3 Import Job List Click Chose file to select the scheduled jobs file you have saved and then click Import Job List to import the scheduled jobs you have set before 3 4 10 Network Diagnosis This page is used for diagnosing the network status methods are Ping Test and Ro...

Страница 61: ... www diacloudsolutions com and others When user choose others user can input the domain IP manual www diacloudsolutions com Start Click Start to start the network diagnosing While running the network diagnosing the settings cannot be changed N A 3 4 11 Privilege Management Privilege management use in order to set the white list of phone numbers and the device operation can be triggered via the spe...

Страница 62: ... router Enable cellular network KQBH or kqbh Dial up the router to internet Disable cellular network DKBH or dkbh The router disconnects from the internet Enable DIA cloud service KQVD or kqvd DIA cloud service enables on the router Disable DIA cloud service GBVD or gbvd DIA cloud service disables on the router Currently there are three the main SMS settings 1 Short Message Control Gateway 2 Short...

Страница 63: ... 3001 Series Industrial Cloud Router 3 38 _3 Description Default Add A Telephone Number ID The maximum allow the 10 phone numbers N A Name Set up a name for phone number The name shall be composed of N A ...

Страница 64: ...ork with The Event management N A Edit Edit the existing event N A Delete Delete the existing event N A Export The List Export the event of SMS Fixed_sms_control_list cfg Import A List Import the event of SMS to the router N A 3 4 12 Event Management This page is used for setting up 3 types of events Communication Verification Alarm Event and SMS Queries Event Communication Verification when this ...

Страница 65: ... Logic operator A A 100 Logic OR Bracket operator A 100 45 Change operation order XOR operation A 100 XOR operation Alarm Event uses can set up the Alarm Name Alarm Description Alarm Criteria Target Receiver and Operation Click Add button to create new alarm event and click Details to edit the existing event and use Delete button to delete the selected event Click Copy to duplicate the event ...

Страница 66: ...teria Setup the alarm trigger condition The format of alarm variable is number 0 4095 the alarm criteria can be a single alarm variable or a formula of one or several alarm criteria For example the formula can be 2048 100 N A Event Interval The time interval of alarm sending 0 Repeat Times The repeated times of alarm sending 0 Alarm Status Enable or disable this alarm setting Enable Alarm Content ...

Страница 67: ...2048 then the alarm content received by users will be 2016 06 01 10 00 00 currently time Voltage 10 The maximum content length is 160 characters Target Receiver Set up the recipient User can maintain the list by Control List Of Event Management in Privilege Management function N A SMS Queries Event user can declar a query event when the mobile number in the Control List of event send a query messa...

Страница 68: ... Register 2048 represents electrical voltage the value of register 2048 is 10 and the query content is set as Date Time Voltage 2048 then the query content received by users will be 2016 06 01 10 00 00 currently time Voltage 10 The maximum content length is 95 characters N A Target Receiver Set up the recipient User can maintain the list by Control List Of Event Management in Privilege Management ...

Страница 69: ...ed to Cloud Yes The existed register values in the cloud WON T be overwritten by the new uploaded register values No The existed register values in the cloud CAN be overwritten by the new uploaded register values No Notice When the values in the register changes the results will be uploaded to cloud 3 5 Cloud Service 3 5 1 Cloud Service In this page user can assign the cloud account which will be ...

Страница 70: ...y the secure tunnel and device name 3 The user also can set IP address manually 4 Click the Bind button the DX router will bind with DIACloud server and established a secure tunnel between DIACloud server and the DX router Meanwhile a new IP will assigns to DX router from DIACloud server assign from the cloud HDCP server or a user specified ...

Страница 71: ... DX router are in the same subnet otherwise PC will not be able to access to the DX router 6 If the network is in the poor condition The binding proccess could be successfully but the Service Status is shown Disable 7 In this situation the browser will access with 192 168 1 1 and the service status will be Disable You can re enable the service status to rebuild the secure tunnel again in cloud con...

Страница 72: ... the username and the password are matched N A Secure Tunnel Select the device under the account to join in a certain secure tunnel network group For secure tunnel related settings go to http www DIACloudsolutions com Default Device Name Set up the name for the device N A Secure Tunnel DHCP When secure tunnel DHCP server is available and the IP address is allocated by the DHCP server in secure tun...

Страница 73: ...ecure tunnel setting For the secure tunnel setting please refer to 5 2 5 Tunnel Network N A Cloud Netmask Display the Cloud Netmask The Cloud Netmask is depended on the secure tunnel setting For the secure tunnel setting please refer to 5 2 5 Tunnel Network N A Device IP User can assign an IP address manually remember that IP address should be the same subnet as the secure tunnel setting For the s...

Страница 74: ...iption Default HTTP Proxy Enable or disable the http proxy Disable Proxy Addr Set up the domain IP of the proxy server N A Proxy Port Set up the port of the proxy server N A Proxy Username Set up the user name to login the proxy server N A Proxy Password Set up the password to login the proxy server N A Save and Test Save the configuration and test to connect to the DIACloud N A ...

Страница 75: ...wed not allowed Yes Firewall of secure tunnel Set up the specified MAC device will be allow or forbid to transmit the data in the secure tunnel Options as below Disable Disable this function Black List If the network device s MAC address is blacklisted these devices will NOT be able to transmit packets to the secure tunnel White List If the network device s MAC address is blacklisted these devices...

Страница 76: ...are most useful to debug an application Info The INFO level designates informational messages that highlight the progress of the application at coarse grained level Warm The WARN level designates potentially harmful situations Error The ERROR level designates error events that might still allow the application to continue running Fatal The FATAL level designates very severe error events that will ...

Страница 77: ...ware Version 4 2 4 1 2 DIACom Installation 4 3 4 1 3 DIACloud Account Registration 4 3 4 1 4 Bind DIACloud Account 4 5 4 2 DIACom Operation 4 6 4 2 1 Setup a Secure Tunnel 4 6 4 2 2 Create a Virtual Serial port 4 11 4 2 3 Remote Control and Monitoring via DIACom 4 12 4 2 4 Automation Startup 4 14 4 ...

Страница 78: ...g the connected device management secure tunnel network creation data upload download and directional transmission If you need to configure or monitor your controller you will need to install programmable logic controller software for example WPLSoft ISPSoft for Delta PLC 4 1 1 Select a Suitable Firmware Version Find a suitable DIACom firmware version according to the following table below for you...

Страница 79: ...s XP Windows 7 32 bit and 64 bit and Windows 8 32 bit and 64 bit 4 1 3 DIACloud Account Registration 1 Before registration you should have a valid email account DIACloud uses your email address as your account 2 Open the DIACloud web page http www DIACloudSolutions com The system will redirect you to the registration page Notice Click at the upper right corner to change the interface language to E...

Страница 80: ...o the email address you have used as your DIACloud account 5 You will find an activation email sent from no reply diacloudsolutions com in your email box Open the email click here link in the email and complete DIACloud account activation operation And you will be redirected to the DIACloud login page Input your account and password to log in to the DIACloud ...

Страница 81: ...rs can set up several groups of secure tunnel for easier device management Device Name the serial number _ Mac address of the device is the device name by default Get IP From Cloud When selecting Yes The system will assign an IP address for the device according to the Secure Tunnel settings and the availability of the IP addresses Take note of the assigned IP address it will be used when logging t...

Страница 82: ... setting function you can set it to avoid the possible limitation 1 Run DIACom and log in with your router s cloud account 2 Click to go into network setting page if need be Http proxy Please fill in the proxy server address port username and password if the LAN needs to set the proxy to access the Internet Click Save button to enable the config Diagnose The user can click the Diagnostic button to...

Страница 83: ... successful the software displays the security tunnel page The security tunnel list is displayed on the left side of the page and the network information of the security tunnel and the device list are displayed on the right Users can choose to use DHCP or manually set the cloud IP address DHCP Obtain an IP address from Cloud automatically when Cloud DHCP function is available Static Manually set t...

Страница 84: ...ing Please change according to the following settings 1 Go to Network and Sharing Center and click on the DIACom Ethernet Adapter for your network connection 2 Right click then click Properties 3 Click the Networking tab Under This connection uses the following items click either Internet Protocol Version 4 TCP IPv4 4 Set the IP address of the local computer manually However you ll need to make su...

Страница 85: ...following information is displayed tunnel connection status local delay to the DIACloud cloud server and the IP address used by the local virtual network adapter The details are as follows 6 After successful connection with the cloud the local computer will be able to use debugging tools or monitoring software to debug monitor and program the remote network interface ...

Страница 86: ...can create different groups of secure tunnels divide different devices into groups according to their needs and implement group management devices To avoid the virtual network card IP network segment and the local computer network card of the actual network to avoid the same network conflict After the secure tunnel is successfully connected you must first disconnect the current connection to selec...

Страница 87: ...ice to enter the Create Virtual Serial Interface The latest device firmware V1 3 3 supports RS 232 and RS 485 at the same time in the transparent mode the interface as shown below Notice If the device s RS 232 RS 485 is not operating in Transparent mode the corresponding button is grayed out DIACom will prompt an error message if the FW version of DX is under V1 3 3 ...

Страница 88: ...l you will need to follow the setups below before using WPLSoft or other configuring monitoring software on your local computer to configure and monitor the connected device remotely 1 Click IP address in the DIACom device list or open a browser and input the IP address of the router which is connected to your remote device on the search bar and then log in 2 Go to the System setup page select the...

Страница 89: ...s S7 200 you can select the PPI in the DIACom to support PPI protocol 4 Open the WPLSoft to check if the COM parameters are consistent with the settings on your router When these parameters are consistent you can use the WPLSoft to configure monitor your device remotely ...

Страница 90: ...omatically log in the required configuration is as follows Users can set according to your needs If you only need DIACom to connect the security tunnel automatically the device list RS 485 and RS 232 do not need to be set 4 Check Start DIACom on windows logon and click OK button to save the settings Notice Login must be checked remember password otherwise DIACom can not be activated automatically ...

Страница 91: ...oud 5 2 5 1 1 Select a Suitable Firmware Version 5 2 5 2 Instructions for DIACloud 5 2 5 2 1 Register and Login 5 2 5 2 2 Home 5 4 5 2 3 Devices 5 6 5 2 4 Alarm 5 16 5 2 5 Secure Tunnels 5 17 5 2 6 Sub Users 5 19 5 2 7 Logs 5 22 5 2 8 Orders 5 23 5 2 9 Profile 5 24 5 ...

Страница 92: ...router meets the requirements in the following table before use Device Model Firmware Version DX 2100 V1 3 0 0 or above DX 2300 V1 0 0 0 or above DX 3001 V1 3 0 0 or above 5 2 Instructions for DIACloud 5 2 1 Register and Login 1 Open the DIACloud web page http www DIACloudSolutions com If you have got an account input your account and password in the following page to log in if you have not got an...

Страница 93: ...he email address you have used as your DIACloud account 4 You will find an activation email sent from no reply DIACloudSolutions com in your email box Open the email click here link in the email and complete DIACloud account activation operation And you will be redirected to the DIACloud login page Input your account and password to log in to the DIACloud ...

Страница 94: ... 3001 Series Industrial Cloud Router 5 4 _5 5 Open the DIACloud web page http www DIACloudSolutions com Log in using your account that you have registered 5 2 2 Home The Home Page will show up after login ...

Страница 95: ...l show the number of Secure Tunnel groups under the account Switching among the Chinese and English Show the service package you selected user can add packeage to shopping cart through Devices function and Profile function Show the alarm message s in latest 7 days Show the profile or logout Online payment process as below 1 After click it will show the detail information in shopping cart 2 Click t...

Страница 96: ...we accept PayPal payments and process credit cards on your order forms 5 2 3 Devices It will switch to page of device list after clicking Devices in navigation bar Item Description You can filter the device base on you input the key word of the device name ...

Страница 97: ...e is displayed currently and you can switch to list of on line device after clicking this icon Show relevant position information of device Refresh pages Show detail information of the device It will show relevant position information of device after you click which is shown as follows It will show the device name and SN of the device after clicking position icon in the map When there is large num...

Страница 98: ... Package More Different buttons are used to switch different pagers Basic information zone Basic information is shown in Overview page IP Address it means the IP that has been bound for device Tunnel Network it means virtual network that has been bound to device Boot Time it means the boot time of device RS232 Mode work modes of RS232 including transparent transmission mode and slave station mode ...

Страница 99: ... that match specific register Click and add the corresponding register and register value then click SAVE button DIACloud server will send the corresponding data to the device Pervious page Next page 1 205 show the current page of register table and the total amount of register table page Register Table Show the register table registers show a maximum of 10 posts per page Register Name Show the re...

Страница 100: ...emeber history device configuration page the menu does not appear History after clicking icon The History and Config options will be shown after clicking Item Description History It represents trend chart of historical data Delete User can delete the all data of this register Config User can customize name of register and content returned History The following figure will be shown after clicking H...

Страница 101: ...pecific time Date End Set the Date End and query the historical data for a specific time Register Value History Diagram The latest trend chart of value of register Time Axis User can change time scope of historical data by sliding Export the data to CSV file Config The following information will be shown after clicking Config ...

Страница 102: ...Byte Alias Name The user can set the name of the register to be displayed in the Alias Name function val function val is used for convert the register value and the grammar of function supported JavaScript is similar There are two examples for function val Example 1 If you want to show the wind speed as 10m s Data unit such as speed 10m s Input the code return val m s in function val as the follow...

Страница 103: ...CH5 Introduction to IOT DIACloud 5 13 _5 Save the configuration 3 SERVICES This page shows the Device Data Usage Device Storage Usage and Account Storage Usage for users Item Description ...

Страница 104: ...e Show the Data Usage History in past 12 months Storage Device Storage Usage Show device storage usage till now and total capacity Account Storage Usage 1 Account storage is the total amount of traffic showing additional purchases 2 Account storage can be shared with all devices under your account 3 Before the device storage is exhausted strorage space the account storage will not be used User can...

Страница 105: ...d 5 15 _5 After Click the in Storage field it will show the storage package select page User can add a package to cart or pay it direct 4 MORE This page will show the Serial Number Software Version Hardware Version and IMEI for users ...

Страница 106: ...ween device and the account Device needs to be un bund after clicking this button and user can recover the device by rebinding 5 2 4 Alarm Click the Alarm in the left menu The warning information in the latest 7 days will be shown in this page The warning information includes name and serial number of device content of warning status of email that is being sent green represents that the email has ...

Страница 107: ...in DIACloud Its objective is to realize virtual Switch across Internet when device is bound to this network it will be equivalent to adding device with one LAN port when PC operates DIACom and creates a virtual network PC and the device will be under the same switch at this time It is shown as follows ...

Страница 108: ...nel network Refresh the tunnel network list Edit the tunnel network Item Description Tunnel Network Information The detail information of tunnel network Network Name User can enter a name of tunnel network DHCP Option Automatic IP Address Assignment by DIACloud DHCP IP Start it represents the beginning IP in automatic IP distribution address pool of DIACloud DHCP IP End it represents the ending IP...

Страница 109: ...e registered through register page of DIACloud http www DIACloudSolutionscom signup are main accounts Every main account can create sub account and users can realize power separation and grouping management of device by conducting authorization for virtual network and DIACom by sub account Use can conduct addition and operation for sub account through the Sub Users page Item Description Search the...

Страница 110: ...om Allow the sub user to access the DIACom if the option is enabled Tunnel Network Allow the sub user to access the Tunnel Network if the option of Tunnel Network is checked Delete a sub user Close the current operation window User can add sub users after clicking the in the page and The following interface will be shown after clicking the in the page ...

Страница 111: ...activation email which is attached with random login password to email box of sub user The account status is Un activated now 3 Goto the mailbox click the hyperlink to complete account activation operation then sub user can login DIACloud with new account 4 The page will link to the following page after clicking the activation link in the email ...

Страница 112: ...er login to DIACloud with main account and the sub user that we created has been activated 5 2 7 Logs This page will show the web operation information of some users It includes login IP setup of register API interface call of DIACloud and other information ...

Страница 113: ... orders Continue to pay for the unpaid orders or cancel the unpaid orders Item Description View the order detail information Pay for the unpaid order Cancel the order order will remove from the list Order detail Payment Method Currently we only support PayPal payment for the world wide user ...

Страница 114: ...unt information Packeage info Show account traffic storage usage till now user can purchase more traffic storage package for this account if need Account traffic storage will share to all devices under this account traffic storage will share to all devices under this account Change Password Change the password of DIACloud user account Parts of old users use password in 6 digits the new password ha...

Страница 115: ...CH5 Introduction to IOT DIACloud 5 25 _5 ...

Страница 116: ...tion to DIACloud APP 6 2 6 1 1 Select a Suitable Firmware Version 6 2 6 1 2 DIACloud APP Installation 6 2 6 2 DIACloud APP Function 6 3 6 2 1 DIACloud APP Login 6 3 6 2 2 Device List 6 4 6 2 3 Device Details 6 5 6 2 4 Registers View 6 6 6 2 5 Alarm List 6 7 6 ...

Страница 117: ...oud platform so that keep users posted anytime and anywhere and therefore improve the manageability of devices optimize the device performance and efficiency save the operation cost and enhance the service quality 6 1 1 Select a Suitable Firmware Version The APP can support the devices below Device Model Firmware Version DX 2100 V1 3 0 0 or above DX 2300 V1 0 0 0 or above DX 3001 V1 3 0 0 or above...

Страница 118: ...ies the user name and password information By scanning the QR code user won t need to input user name By default the APP will connect the default DIACloud server in the cloud if the APP is to connect other servers QR code should be scanned to provision the APP DIACloud account Email format The password of DIACloud account click to see what are you input Auto Login Save the password and login the A...

Страница 119: ...value of the register can be changed in the APP as well In the alarm tab users can read the alarm messages Item Description Logoff or exit App Search Search device base on key word All Online Click ALL to show all device Click Online only show online device Digit at the back is the all online device count Device list Display device online offline status device name device serial number Click it wi...

Страница 120: ... device Time The time when the device is online IP IP Address of the device Account DIACloud account activating the device Mode The working mode of RS485 and RS232 RS232 Transparent transmission mode or Slave mode RS485 Transparent transmission mode Slave mode Master mode Map Showing the location of the device on the map P S DX 2300 Series doesn t support this function ...

Страница 121: ...age to switch to the register page In the register page the user can browse the collected data The register data can be refreshed by the pull down screen When the number of registers is large you can pull up the screen to display more data Item Description Refresh the register data Edit the register value ...

Страница 122: ...e alarm criteria are met the device will send out alarm messages User can click the Alarm tab to read the alarm messages When there are new alarm messages the number of the unread messages will be shown on the icon Alarm tab will be shown by clicking icon the alarm messages in Red are unread messages Digit in parentheses is the number of alarm messages Pull down the APP to refresh the alarm list ...

Страница 123: ...DX 3001 Series Industrial Cloud Router 6 8 _6 ...

Отзывы: