DX-3001 Series Industrial Cloud Router
3-30
_3
Description
Default
Working Mode
The default is OFF. Other options are:
Modbus TCP Server (Slave
): for applications of a PLC to read/write the
open registers in router. It supports up to 32 connections from client.
Modbus TCP Client (Master):
for router to read/write the open registers
in a PLC. It supports to connect to 4 different servers at most.
OFF
Modbus TCP Client
Server IP
Set up the IP address of a PLC in the Modbus TCP
Client mode
N/A
Server Port
Set up the server port of a PLC in the Modbus TCP
Client mode
502