background image

http://www.delta.com.tw/industrialautomation/

 

2006-10-24

5011650900-H2E0

 

 

High-Speed, Multi-Functional 
Programmable Logic Controller

 

Instruction Sheet 

 

Warning 

3

 

This instruction sheet only provides introductory information on electrical specification, functions, wiring, 
trouble-shooting and peripherals. For detailed information on programming and instructions, please refer to 
“DVP-PLC Application Manual: Programming”. For how to purchase its peripheral devices, please refers to the 
manual enclosed with the product. 

 

3

 

DVP-EH2 is an OPEN-TYPE device and therefore should be installed in an enclosure free of airborne dust, humidity, 
electric shock and vibration. The enclosure should prevent non-maintenance staff from operating the device (e.g. key 
or specific tools are required for opening the enclosure) in case danger and damage on the device may occur. 

 

3

 

DO NOT connect input AC power supply to any of the I/O terminals; otherwise serious damage may occur. Check all 
the wiring again before switching on the power and Do NOT tough any terminal when the power is switched on. 
Make sure the groud terminal 

  is correctly grounded in order to prevent electromagnetic interference. 

X

 

Introduction

 

1.1  Model Explanation & Peripherals 

 

™

 Nameplate Explanation 

 

100~240VAC 50/60Hz 30VA MAX

MODEL

POWER INPUT

OUTPUTMODULE 2.0A 250Vac 50/60Hz RES LOAD

32EH00R2T6160018

VX.XX

DELTA ELECTRONICS,INC.

MADE IN XXXXXX

DVP32EH00R2

Delta PLC model name

Power input specification

Output module specification

Barcode & series No.

Firmware version

 

 
 

™

 Model/Serial No. Explanation

 

 

32EH00R2 0 T 6 16 0018

Model name

Version No.

Production plant (Taoyuan)

Production year (2006)

Production week

Production No.

 

1.2  Product Profile & Outline 

1

2

3

5

9

4

9

6

10

5

4

7

8

 

Open COM1 cover 

 

 

 

c

  Communication port cover 

h

    Extension module connection port cover 

d

  I/O terminal cover 

i

  Input indicator 

e

  Function card/memory card cover 

j

  Output indicator 

f

  I/O terminals 

k

  DIN rail clip 

g

  I/O terminal No. 

l

  DIN rail (35mm) 

 

3

1

2

6

7

1

2

5

4

8

 

 

Open COM2 cover 

 

 

c

  Mounting screw 

g

    Memory card port 

d

  Direct mounting hole 

h

  POWER/RUN/BAT.LOW/ERROR indicator 

e

  Battery socket 

i

    Extension module connection port 

f

    Function card mounting hole 

 

 

Removable Terminal Block

COM 2 (RS-485)

RUN / STOP SWITCH

VR 0

VR 1

COM 1 (RS-232)

Battery

Remove RS-485 

terminal 

 

 

Part 

Description 

COM2 (RS-485) 

For both master & slave modes 

RUN/STOP switch 

PLC RUN/STOP control 

VR0 

Enable M1178/corresponding 
value of D1178 

VR1 

Enable M1179/corresponding 
value of D1179 

COM1 (RS-232) 

For slave mode 

Battery 

Shall be changed within 1 min. 

 

1.3  Installation of function card/memory card (optional accessories) 

Remove function card 

 

Remove memory card 

 

Close the cover 

 

For details, see the instruction sheets of these accessories. 

Y

 

Electrical

 

Specifications

 

           

      Model 

Item 

16EH00

†

20EH00

†

32EH00

†

40EH00

†

48EH00

†

64EH00

†

80EH00

†

Power supply 
voltage 

100 ~240VAC (-15% ~ 10%); 50/60Hz 

±

 5% 

Fuse capacity 

2A/250VAC 

Power 
consumption 

50VA 50VA 60VA 60VA 60VA 80VA 80VA 

DC24V current 
supply 

500mA 500mA 500mA 500mA 500mA 500mA 500mA 

Power protection 

DC24V; output short-circuited 

Withstand voltage 

1500VAC (Primary-Secondary); 1500VAC (Primary-PE); 500VAC (Secondary-PE) 

Insulation 
resistance 

5 M

 (all I/O point-to-ground: 500VDC) 

Noise immunity 

ESD: 8KV Air Discharge; EFT: Power Line: 2KV, Digital I/O: 1KV, Analog & Communication I/O: 250V 
Damped-Oscillatory Wave: Power Line: 1KV, Digital I/O: 1KV, RS: 26MHz ~ 1GHz, 10V/m 

Earth 

The diameter of grounding wire shall not be less than that of L, N terminal of the power. (When many PLCs are 
in use at the same time, please make sure every PLC is properly grounded.) 

Operation/storage 

Operation: 0ºC ~ 55ºC (temperature); 50 ~ 95% (humidity); pollution degree 2 
Storage: -40 ºC ~ 70 ºC (temperature); 5 ~ 95% (humidity) 

Vibration/shock 
immunity 

International standards: IEC1131-2, IEC 68-2-6 (TEST Fc)/IEC1131-2 & IEC 68-2-27 (TEST Ea) 

Weight 

(g) 

500/480 520/500 652/612 710/675 748/688 836/756 948/848 

™

 Input point specifications

 

24VDC single common port input 

Spec. 

Items 

Low speed   

High speed (200KHz) 

Note 

Input wiring type 

Change wiring from S/S to SINK or SOURCE 

Input indicator 

LED display; light on = ON, light off = OFF 

Input voltage 

24VDC 

±

 10% 

Off

€

On 16VDC 

±

 10% 

Active Level 

On

€

Off 12VDC 

±

 10% 

Response Time / Noise Immunity 

10 ms 

0.5us 

Input point X0 ~ X7, X10 ~ X17 
can conduct 10 ~ 60ms digital 
filter adjustment 

™

 Output point specifications

 

Single common port transistor output 

Spec. 

Items 

Low speed   

High speed* 

Single common port relay output 

Max. frequency 

10KHz 

200KHz 

Load ON/OFF control 

Output indicator 

LED display; light on = ON, light off = OFF 

Min. load 

2mA/DC power supply 

Working voltage 

5 ~ 30VDC 

250VAC, 30VDC 

Insulation 

Photocoupler isolation 

Magnetic isolation 

Current specification 

0.3A/1 point @ 40ºC 

<1KHz, 0.3A/1 point @ 40°C 

1KHz, 30mA/1 point @ 40°C 

2A/1 point (5A/COM) 

75 VA (conductive), 90W (resistive) 

Off

€

On 20us 

Max. output 
delay time 

On

€

Off 30us 

0.2us 10ms 

Over-current protection 

N/A 

Mechanical life 

N/A 

2×10

7

 times (without load) 

Electrical life 

N/A 

1.5×10

5

 times (5A 30VDC); 5×10

5

 

times (3A 120VAC); 3×10

4

 times 

(5A 250VAC) 

*High-speed output points (Y0, Y2) are only in DVP20EH2 and DVP32EH2; high-speed output points (Y0, Y1, Y2, Y3, Y4, Y6) are only in 
DVP40EH2. 

Z

 

Installation & Wiring

 

3.1 Dimension 

4.6 X

2

W

W1

80

.0

9

0.

0

82.2

 

 

Model 

W (mm) 

W1 (mm) 

DVP16EH00R2/T2 113 

103 

DVP20EH00R2/T2 113 

103 

DVP32EH00R2/T2 143.5  133.5 
DVP40EH00R2/T2 158.8  153.8 
DVP48EH00R2/T2 174 

164 

DVP64EH00R2/T2 212 

202 

DVP80EH00R2/T2 276 

266 

 

3.2 Wiring 

terminals 

16EH2 

X7

X6

X5

X4

X3

X2

X1

X0

Y0

Y1 Y2 Y3

Y4

Y5 Y6

C6

C2

C1

C0

S/S

Y7

C3 C4 C5

C7

 

 

 

20EH2 

X13

X12

X11

X10

X7

X6

X5

X4

X3

X2

X1

X0

Y0

Y1

C1

Y2

Y3

Y4

C3

C0

S/S

C2

C4

+24V

24G

Y6

Y5

Y7

 

 

 

32EH2 

Relay 

X17

X16

X15

X14

X13

X12

X11

X10

X7

X6

X5

X4

X3

X2

X1

X0

Y0

Y1

Y2

Y3

Y4 Y5

Y6

C3

C2

C1

C0

Y7

Y12

Y13

Y16

Y17

Y15

Y14

Y11

Y10

S/S

 

 

 

32EH2 

Transistor 

X17

X16

X15

X14

X13

X12

X11

X10

X7

X6

X5

X4

X3

X2

X1

X0

Y0

Y1

C1

Y2

Y3 Y4

Y6

C5

C3

C0

Y5

Y12

Y11

Y17

Y16

Y14

Y13

Y10

Y7

S/S

C2

C6 Y15

C4

 

 

 

40EH2 

Relay 

X23

X22

X21

X20

X17

X16

X15

X14

X13

X12

X11

X10

X7

X6

X5

X4

24G Y0

C0

Y2 Y3

C3

C5

C4

C2

24V

Y12

Y10

Y6

Y4

S/S

Y14 Y16

Y15

C1

Y5

Y11

C6

X24 X26

X25 X27

Y1

Y7

Y13

Y17

X1

 

 

 

40EH2 

Transistor 

X23

X22

X21

X20

X17

X16

X15

X14

X13

X12

X11

X10

X7

X6

X5

X4

24G Y0

C0

Y2 Y3

C4

C2

C1

24V

Y12

Y10

Y6

Y4

S/S

Y14 Y16

Y15

Y5

Y11

C5

X24 X26

X25 X27

Y1

Y7

Y13

Y17

X1

C3

 

 

 

48EH2 

X17

X16

X15

X14

X13

X12

X11

X10

X7

X6

X5

X4

X3

X2

X1

X0

Y0

Y1

Y2

Y3

Y4 Y5

Y6

C3

C2

C1

C0

Y7

Y12

Y13

Y16

Y17

Y15

Y14

Y11

Y10

S/S

X27

X26

X25

X24

X23

X22

X21

X20

C4 Y21

Y22

Y27

Y23

Y26

Y24

Y20

Y25

 

 

 

64EH2 

X17

X16

X15

X14

X13

X12

X11

X10

X7

X6

X5

X4

X3

X2

X1

X0

Y0

Y1

Y2

Y3

Y4 Y5

Y6

C3

C2

C1

C0

Y7

Y12

Y13

Y16

Y17

Y15

Y14

Y11

Y10

S/S

X27

X26

X25

X24

X23

X22

X21

X20

C4 Y22

Y21

Y27

Y24

Y25

Y23

Y20

Y26

X37

X36

X35

X34

X33

X32

X31

X30

C5 Y31

Y32

Y37

Y33

Y36

Y34

Y30

Y35

 

 

 

80EH2 

X15

X14

X13

X12

X11

X10

X7

X6

X5

X4

X3

X2

X1

X0

Y0

Y1

Y2

Y3

Y4 Y5

Y6

C3

C2

C1

C0

Y7

Y12

Y13

Y16

Y17

Y15

Y14

Y11

Y10

S/S

X23

X22

X21

X20

X17

X16

C4 Y22

Y21

Y27

Y25

Y23

Y20

Y26

X31

X30

X33

X32

X27

X26

X25

X24

C6 Y32

Y31

Y37

Y34

Y35

Y33

Y30

Y36

X35

X34

X37

X36

X41

X40

X43

X42

X45

X44

X47

X46

C5

Y24

C7 Y42

Y41

Y47

Y44

Y45

Y43

Y40

Y46

 

 

 

3.3 Installation 

™

 

How to install DIN rail 

DVP-PLC can be secured to a cabinet by using the DIN rail of 35mm in height and 7.5mm 
in depth. When mounting PLC to DIN rail, be sure to use the end bracket to stop any 
side-to-side movement of PLC and reduce the chance of wires being loosen. A small 
retaining clip is at the bottom of PLC. To secure PLC to DIN rail, place the clip onto the rail 
and gently push it up. To remove it, pull the retaining clip down and gently remove PLC 
from DIN rail, as shown in the figure.

 

 

 

™

 

How to screw 

Please use M4 screw according to the dimension of the product. 
 

™

 

Please install PLC in an enclosure with sufficient space around it to allow heat 

dissipation as shown in the figure. 

 
 

DVP MPU

> 50mm

> 50mm

> 50mm

> 50mm

 