the execution of pattern No. 0. If set to 

, it indicates the program will stop after executing the current 

pattern and the temperature will keep at the set point of the last step. 

 

Cycle Parameter : 

Additional execution cycle number. For example, when set 

  to 2, it indicates that pattern 

No. 4 should execute twice in addition. Include origin one time execution, total execute three times. 

 

Actual Step Parameter : 

Execution step number per pattern (can set to 0 ~ 7). For example, when set

 

 to 

2, it indicates that pattern No 7 will not execute other steps than step 0 to step2. 

 

Execution : 

When 

 is set to 

, the program will start to execute in order from the step 0 of start 

pattern. When 

 

is set to

 

, the program will stop and the control output is disabled. When 

  is set to

 

, the program will stop and the temperature at that time will be controlled at the set 

point before program stop. Select 

 

again, then the program will restart and execute from step 0 of 

start pattern. When 

  is set to

 

, the program will hold and the temperature at that time will be 

controlled at the set point before program hold. Select

 

 

again, then the program will follow the step 

before hold and start to execute through the rest of the time. 

 

Display : 

During PID program control, the SV default display is P-XX, P indicates the current execution pattern 

and XX indicates the current execution step. Press 

 

to change the display item. After select 

press 

 key, and then the temperature set point of the current execution step will display on SV 

display.After select 

, press

 

  key, and then the residual time of the current execution step will 

display on SV display. 

 

12  

PID Control

 

 

One group can be selected from any one of 4 groups PID parameters (P, I, D, IOF) for PID control. After AT, PID 

value and temperature setting will be stored in the selected one group. 

  ~

:

 

PIDn, n=0~4 from which 

0~3 correspond to each PID parameter. 

: n=4, auto PID parameter. Program will automatically select a most 

useful PID parameter based on current temperature setting. Displayed SV values correspond to 

~

 

~

:

 

Temperature setting corresponded to the selected PID parameter via user-defined or AT. 

 

Valve Control: 

When use valve control as output control, there are 2 Relay outputs for motor forward/reverse control, one (output 

1) for valve open the other (output 2) for valve close. The output volume is controlled by valve open/close and it 
can be set with feedback function enabled or disabled. When feedback is disabled, output 1 will keep output while 
valve fully opens and output 2 will keep output while valve fully closes. But if feedback is enabled, please follow the 
parameter setting for valve control as follows: 

 

: Time for valve from full close to full open. 
: Dead Band setting of valve. The value of current valve output minus previous one must be greater than 

Dead Band value; otherwise, valve will remain OFF. 

: Signal feedback setting, ON for enabling feedback and OFF for disabling feedback. 

When 

set to ” 1”, it means signal feedback function is activated and will come up selections as follows: 

a. 

: Upper/Lower limit of valve feedback by auto-tuning. 

must set to

for showing up this 

selection. 

b. 

: D/A value when value fully opens. Set 

to be ”1” for auto setting or ”0” for manual setting. 

c. 

: D/A value when value fully closes. Set 

to be ”1” for auto setting or “0” for manual setting. 

Note: If feedback function setting is with problem, program will see the setting as feedback disabled. 
 
 

 
 

Содержание DT4848

Страница 1: ...http www delta com tw industrialautomation DELTA Temperature Controller DTB Series User Manual...

Страница 2: ...e correct polarity of terminals 6 Do not install and or use the controller in places subject to Dust or corrosive gases and liquid High humidity and high radiation Vibration and shock High voltage and...

Страница 3: ...de C Celsius F Fahrenheit Press this key to increase values displayed on the SV display Hold down this key to speed up the incremental action Mode key key O O O 3 Ordering Information DTB 1 2 3 4 5 6...

Страница 4: ...racter 7 segment LED display Process value PV Red color Set point SV Green color Thermocouple K J T E N R S B L U TXK 3 wire Platinum RTD Pt100 JPt100 Sensor Type Analog input 0 5V 0 10V 0 20 m A 4 20...

Страница 5: ...emperature set point and displays the temperature process value Use keys to set the temperature set point Setting method While in any function mode press the key to select the desired function and use...

Страница 6: ...m full close to full open Display when valve control is ON Press Display and adjust output value of 1st output group Display in PID control mode and manual RUN mode Press ASCII RTU communication forma...

Страница 7: ...Press to return pattern No editing mode Press to set actual step No Edit time of step No 7 of pattern No 0 unit is hh mm 7 Dual Loop Output Control Heating Cooling Control OFF PV Set point ON Heating...

Страница 8: ...initial setting mode The alarm output is activated whenever the process temperature value PV is getting higher or lower than the set point of alarm limit Set Value Alarm Type Alarm Output Operation 0...

Страница 9: ...t You can set current alarm range between 0 5A 30A display resolution is 0 1A and measure accuracy is 0 5A 10 EVENT Inputs Function 5 There are two optional event inputs contact inputs supported EVENT...

Страница 10: ...ay on SV display 12 PID Control One group can be selected from any one of 4 groups PID parameters P I D IOF for PID control After AT PID value and temperature setting will be stored in the selected on...

Страница 11: ...tents of the Temperature Sensor Type and Temperature Range for detail 1005H Control method 0 PID 1 ON OFF 2 manual tuning 3 PID grogram control 1006H Heating Cooling control selection 0 Heating 1 Cool...

Страница 12: ...102BH Read pushbutton status b0 Set b1 Select b2 Up b3 Down 0 is to push 102CH Setting lock status 0 Normal 1 All setting lock 11 Lock others than SV value 102DH CT read value Unit 0 1A 102FH Softwar...

Страница 13: ...0 0 02 0 0 6 0 0 02 0 mm in DTB4824 1 4 3 2 5 6 AC 100 240V 50 60 Hz 5VA Tc RTD OUT 1 DATA DATA RS 485 7 9 8 10 11 12 V OUT 2 ALM V IN L N DTB4848 65 0 min 2 56 45 0 1 77 45 0 1 77 60 0 min 2 36 0 6...

Страница 14: ...9 in 9 5 mm 0 37 in 80 0 mm 3 15 in 44 75 mm 1 76 in 45 0 mm 1 77 in 0 6 0 45 0 mm 1 77 in 0 6 0 0 02 0 0 02 0 DTB4896 DTB9696 48 0 mm 1 89 in 12 8 mm 0 50 in 79 2 mm 3 12 in 91 0 mm 3 58 in 95 7 mm 3...

Страница 15: ...B4848 4896 9696 Mounting Method 1 3 2 0 6 8 m m M a x 17 Error Acknowledge and Display Communication error code response description Error status 102EH 4750H PV read back 1000H 4700H Error status 0001...

Страница 16: ...AN TEL 886 3 362 6301 FAX 886 3 362 7267 NORTH SOUTH AMERICA DELTA PRODUCTS CORPORATION Sales Office P O BOX 12173 5101 DAVIS DRIVE RTP NC 27709 U S A TEL 1 919 767 3813 FAX 1 919 767 3969 EUROPE DELT...

Отзывы: