background image

 

 

8

  F 

When PV reaches SV, output is enabled but counting continues. Recounting starts after reset signal is 
over. Output 2 remains. 

  N 

When PV reaches SV, output is enabled but counting stops. Recounting starts after reset signal is over. 
Output 2 remains. 

  C 

When PV reaches SV, recounting executes automatically. Output 2 is pulse output. Output 1 remains till 
Output 2 is over. 

  R 

When PV reaches SV, counting stops till Output 2 (pulse) is over for recounting. Output 1 remains till 
Output 2 is over. 

  K 

When PV reaches SV, output is enabled but counting continues. Recounting starts after reset signal is 
over. 

  P 

When PV reaches SV, output is enabled and recounting is automatically executed. But display of 
counting remains till Output 2 (pulse) is over. 

  Q 

When PV reaches SV, output is enabled but the counting continues. Recounting starts after Output 2 
(pulse) is over. 

  A 

When PV reaches SV, output is enabled but the counting stops. Recounting starts and Output 2 (pulse) 
executes after reset signal is over.   

  S When 

PV 

 SV1, Output 1 is enabled. When PV 

 SV2, Output 2 is enabled 

  T When 

PV 

 SV1, Output 1 is enabled. When PV 

 SV2, Output 2 is enabled. 

  D  When SV=PV, output is enabled but counting continues. Addition and subtraction modes are valid. 

The time of Output 1 and Output 2 (pulse) can be setup separately, ranging from 0.01 to 99.99 secs. Recounting refers to 
counting up or addition/subtraction counting starting from 0 and counting down starting from SV. The counting range: 
-99999~999999. The counting will restart from 0 if the counting exceeds the range. 

999999

RESET

SV2

SV1

OUT2

OUT1

0

T

T

T

T

T T T

T

T

T

RESET

999999

SV2

SV1

0

OUT2

OUT1

T

T

RESET

999999

SV2

0

OUT2

OUT1

SV1

RESET

999999

SV2

SV1

0

OUT2

OUT1

T

T

T

T

T

T

T

T

T

T

T

T

T T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

Input mode

Up

Down

Up/Down A, B,  C

F

N

C

R

Output

mode
setting

   

VARITEL INGENIERIA ELECTRONICA S.A.

[email protected] - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545

Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina. 

Содержание CTA4000A Series

Страница 1: ...ected to proper terminals 6 Keep away from high voltage and high frequency environment during installation in case of interference 7 Prevent using the device in premises which contain Dust or corrosiv...

Страница 2: ...operation mode for more than 3 seconds to enter configuration mode Press MODE once to switch among parameters To return to operation mode press MODE for more than 3 seconds Ordering Information CTA 2...

Страница 3: ...data or not while switching off power MODE Setup pre scale value MODE Setup the decimal point MODE Setup the pulse width of output 2 MODE Tachometer Select a function MODE Setup output mode of Tachome...

Страница 4: ...from 0 to 99 99 secs 0 Hold output Setup output modes Setup the counting unit of the timer sec 0 01 9 999 99 A unit 10ms Max counting 9 999 99 secs sec 0 1 99 999 9 A unit 0 1sec Max counting 99 999 9...

Страница 5: ...l Pause signal Clear signal Output signal Up Down SV SV Repeat Cycle 0 0 timer output set as 0 Power signal Start signal Pause signal Clear signal Output signal Up Down SV SV Repeat Cycle t t t timer...

Страница 6: ...s include 1 stage counting 2 stage counting batch counting total counting and dual counting 1 stage Only 1 SV is allowed See output modes of counter 2 stage 2 SVs 2 PVs are allowed See output modes of...

Страница 7: ...A n n 1 n 2 n 3 n 4 n 5 H L H L CP1 CP2 0 Present Value CP1 Counter input prohibited CP2 Counter input Note has to be larger than width of min Input signal A Command counting up down UD_A Individual c...

Страница 8: ...t the counting stops Recounting starts and Output 2 pulse executes after reset signal is over S When PV SV1 Output 1 is enabled When PV SV2 Output 2 is enabled T When PV SV1 Output 1 is enabled When P...

Страница 9: ...OUT2 OUT1 Output mode setting Input mode Up Down Up Down A B C K P Q A T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T VARITEL INGENIERIA ELECTRONICA S A info varitel c...

Страница 10: ...RTU mode Function codes 03H register read and 06H single register write Function code 03H can read maximum 8 words at a time ASCII Mode Register Read 03H Response Register Write 06H Response Start ch...

Страница 11: ...ter Content Remark 1000H 0 V V V PV1 Low byte 1001H 0 V V V PV1 High byte 1002H 0 V PV2 Low byte 1003H 0 V PV2 High byte Available on batch total dual counter and mixed mode 1004H 0 V V V SV1 Low byt...

Страница 12: ...Tachometer Function Measuring Rotation speed Measuring pulse width and determining current frequency Output methods Lo Lo Lo Hi Hi Lo Hi Hi OUT2 set value Measurement value OUT1 set value OUT1 OUT2 OU...

Страница 13: ...eed ON 10KCPS OFF 30CPS Unit of Timer See Table 2 Counting speed ON 10kHz OFF 30Hz 4 Output mode of counter See Table 3 Output mode of Timer See Table 3 Output mode of Tachometer See Table 3 3 Output...

Страница 14: ...D series Multi function input pin Counter Timer Tachometer Timer Counter CP1 CP1 CP1 CP2 Gate Gate Reset1 Reset1 Reset1 Reset1 Reset2 Start Start VARITEL INGENIERIA ELECTRONICA S A info varitel com ww...

Страница 15: ...he top and bottom of the controller and push the mounting bracket forward until the bracket stops at panel wall 3 Insert and tighten screws on bracket to secure the controller in place VARITEL INGENIE...

Отзывы: