Delta CTA4000A Series Скачать руководство пользователя страница 2

 

 

2

TOTAL 

“Total Counting Mode” in Counter and 
Tachometer function 

TMR 

Light on when Timer function is executing 



 Key Operation 

 

Increase and decrease SV or change parameter settings. 

 

Left move 1 digit of the selected digit. The indicator of the selected digit will flash. 

MODE

 

Save the set parameters or switch among functions. 

LOCK  

Prevent settings from being changed. Key-protected mode still works after the power is switched off. Press 

LOCK to enter key-protected mode. In non-key-protected status, press LOCK to enter Lock 1. In Lock 1, 

press LOCK again to enter Lock 2. Press 

MODE

 

and  

at the same time to disable key-protected mode.

(Lock 1

disables the functions of all keys. 

(Lock 2) allows users to change SV and 

functions of RESET remain. LOCK only functions in non-key-protected status. 

RESET   Clear and reset PV. 



 

Modes: Operation Mode and Configuration Mode 

Operation 

When the power is on, the timer/counter/tachometer is in the operation mode. Press   

to 

change SV, or 

 

to make change on a desired digit. The indicator of the selected digit will flash. 

After the change is made, press 

MODE

 

to save the setting. If SV or parameters are not changed, press 

MODE

 

once to switch between SET1 and SET2.

 

Configuration 

Press 

MODE

 

in operation mode

 

for more than 3 seconds to enter configuration mode. Press 

MODE

 

once to switch among parameters. To return to operation mode, press 

MODE

 

for more than 3 seconds.

 

 

 

Ordering Information

 

CTA

2

3

4

5

6

1

 

n

 

Product name

  CTA: Delta Counter/Timer/Tachometer A series 

q

 

Preset stage

 

0: 2 preset stage 

o

 

Panel size

 

4: 48mm x 48mm 1/16DIN 

r

 

Communication

 

0: none; 1: RS-485 

p

 

Output 2

 

0: NPN; 1: Relay 

s

 

Power supply

 

A: AC 100 ~ 240V;   
D: DC 21.6 ~ 26.4V 

 

 

 

Specification 

Model name 

CTA4000A series 

CTA4000D series 

Power input 

AC 100 ~ 240V, 50/60Hz 

DC 24V 

Input voltage range 

85 ~ 110%, rated voltage 

DC 21.6 ~26.4V 

Power consumption 

Less than 10VA 

Less than 5W 

External power supply 

12V DC ±10%, 100mA 

Display 

Double-line, 6-digit negative transmissive LCD display 
Non-voltage input (NPN): ON impedance 1K ohm max. ON residual voltage: 2V max. 

Input signal 

Voltage input (PNP): High level: 4.5 to 30V DC, Low level: 0 to 2V DC 
Relay: SPST max.250V AC, 5A (resistance load) 

Output 1 

Transistor: NPN open collector. When 100mA /30V DC, residual voltage=1.5V DC max. 
Relay: SPDT max.250V AC, 5A (resistance load) 

Output 2 

Transistor: NPN open collector. When 100mA /30V DC, residual voltage=1.5V DC max. 

Dielectric strength 

2,000V AC, 50/60 Hz for 1 minute

1,000V AC, 50/60Hz for 1 minute 

VARITEL INGENIERIA ELECTRONICA S.A.

[email protected] - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545

Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina. 

Содержание CTA4000A Series

Страница 1: ...ected to proper terminals 6 Keep away from high voltage and high frequency environment during installation in case of interference 7 Prevent using the device in premises which contain Dust or corrosiv...

Страница 2: ...operation mode for more than 3 seconds to enter configuration mode Press MODE once to switch among parameters To return to operation mode press MODE for more than 3 seconds Ordering Information CTA 2...

Страница 3: ...data or not while switching off power MODE Setup pre scale value MODE Setup the decimal point MODE Setup the pulse width of output 2 MODE Tachometer Select a function MODE Setup output mode of Tachome...

Страница 4: ...from 0 to 99 99 secs 0 Hold output Setup output modes Setup the counting unit of the timer sec 0 01 9 999 99 A unit 10ms Max counting 9 999 99 secs sec 0 1 99 999 9 A unit 0 1sec Max counting 99 999 9...

Страница 5: ...l Pause signal Clear signal Output signal Up Down SV SV Repeat Cycle 0 0 timer output set as 0 Power signal Start signal Pause signal Clear signal Output signal Up Down SV SV Repeat Cycle t t t timer...

Страница 6: ...s include 1 stage counting 2 stage counting batch counting total counting and dual counting 1 stage Only 1 SV is allowed See output modes of counter 2 stage 2 SVs 2 PVs are allowed See output modes of...

Страница 7: ...A n n 1 n 2 n 3 n 4 n 5 H L H L CP1 CP2 0 Present Value CP1 Counter input prohibited CP2 Counter input Note has to be larger than width of min Input signal A Command counting up down UD_A Individual c...

Страница 8: ...t the counting stops Recounting starts and Output 2 pulse executes after reset signal is over S When PV SV1 Output 1 is enabled When PV SV2 Output 2 is enabled T When PV SV1 Output 1 is enabled When P...

Страница 9: ...OUT2 OUT1 Output mode setting Input mode Up Down Up Down A B C K P Q A T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T VARITEL INGENIERIA ELECTRONICA S A info varitel c...

Страница 10: ...RTU mode Function codes 03H register read and 06H single register write Function code 03H can read maximum 8 words at a time ASCII Mode Register Read 03H Response Register Write 06H Response Start ch...

Страница 11: ...ter Content Remark 1000H 0 V V V PV1 Low byte 1001H 0 V V V PV1 High byte 1002H 0 V PV2 Low byte 1003H 0 V PV2 High byte Available on batch total dual counter and mixed mode 1004H 0 V V V SV1 Low byt...

Страница 12: ...Tachometer Function Measuring Rotation speed Measuring pulse width and determining current frequency Output methods Lo Lo Lo Hi Hi Lo Hi Hi OUT2 set value Measurement value OUT1 set value OUT1 OUT2 OU...

Страница 13: ...eed ON 10KCPS OFF 30CPS Unit of Timer See Table 2 Counting speed ON 10kHz OFF 30Hz 4 Output mode of counter See Table 3 Output mode of Timer See Table 3 Output mode of Tachometer See Table 3 3 Output...

Страница 14: ...D series Multi function input pin Counter Timer Tachometer Timer Counter CP1 CP1 CP1 CP2 Gate Gate Reset1 Reset1 Reset1 Reset1 Reset2 Start Start VARITEL INGENIERIA ELECTRONICA S A info varitel com ww...

Страница 15: ...he top and bottom of the controller and push the mounting bracket forward until the bracket stops at panel wall 3 Insert and tighten screws on bracket to secure the controller in place VARITEL INGENIE...