12
1013H
2
V
V
Pulse width of output 2
Range: 1 ~ 9,999; Unit: 10ms, 0: Sustained mode
1014H
0
V
V Decimal position
0 ~ 3
1015H
1000
V
V Pre-scale value
Range: 1 ~ 99,999; Unit: 0.001
1016H
0
V
Data save on loss power
0: No action; 1: Save present data
1017H
0
V
V
V Reset min. pulse width
0: 20ms; 1: 1ms
1018H 0 V Tachometer
output mode
0: Lo-Lo; 1: Lo-Hi; 2: Hi-Lo; 3: Hi-Hi (Tachometer)
1019H
0
V Delay time while power on 0 ~ 999; Unit: 0.1s
101AH
0
V Average of input data
0 ~ 3
101BH
0
V
V
V Front panel lock status
0: Normal; 1: Lock all; 2: SV can be set
101EH
V
V
V Read version
Read only
Value
Timer Output Mode
Timer
Display
Counter
Output
Mode
Value
Timer Output Mode
Timer
Display
Counter
Output Mode
0
Signal ON Delay1
0.01s
F
6
Repeat Cycle
1 min
Q
1
Signal ON Delay2
0.1s
N
7
Repeat Cycle Hold
hr, min, 1s
A
2
Signal OFF Delay
1s
C
8
Repeat Cycle 2
hr, 1min
S
3
Signal ON
min, 0.01s
R
9
Signal Cumulate
1hr
T
4
Power ON Delay
min, 0.1s
K
10
Signal Twin ON Start
D
5
Power ON Delay Hold
0.1 min
P
11
Signal Twin OFF Start
Table 1
Tachometer Function
Measuring Rotation speed: Measuring pulse width and determining current frequency
Output methods: Lo-Lo, Lo-Hi, Hi-Lo, Hi-Hi
OUT2 set value
Measurement value
OUT1 set value
OUT1
OUT2
OUT1 set value : OUT1 ON
Measurement value
OUT2 set value : OUT2 ON
(LO-LO)
OUT2 set value
Measurement value
OUT1 set value
OUT1
OUT2
Measurement value
OUT1 set value : OUT1 ON
Measurement value
OUT2 set value : OUT2 ON
(LO-HI)
OUT2 set value
Measurement value
OUT1 set value
OUT1
OUT2
(HI-LO)
Measurement value
OUT1 set value : OUT1 ON
Measurement value
OUT2 set value : OUT2 ON
OUT2 set value
Measurement value
OUT1 set value
OUT1
OUT2
(HI-HI)
Measurement value
OUT1 set value : OUT1 ON
Measurement value
OUT2 set value : OUT2 ON
Delay time after switching on the power
:
The tachometer will start to run when the set delay time is due
after the power is switched on. (Range of delay time: 0.1 ~ 99.9 secs.)
Setup average value of input filter
:
Range for obtaining average (n = 0 ~ 3). This parameter obtains the
average of 2
n
input data for more stable output value.