Communication 

 

Enable/ 
Disable 
write 
function  

MODE

 

 

ASCII 
/RTU 
format 
selection 

MODE

 

Address 
setting 

 
 

MODE

 

 

Baud rate 
setting 

 
 

MODE

 

 

Date length 
setting 

 
 

MODE

 

 

Parity bit 
setting 
 
 

MODE

 

 

Stop bit 
setting 
 

 

MODE

 

 
 

Back to 

“select a 
function”

 



 Open Communication parameter method: 

1) Press “LOCK” key first, CTA will be in the lock status. 

2) Press

  at the same time over 2 seconds, CTA will go to the special mode. Display

PASS

and

CtAxx0

3) When PV display

PASS

, Press

keys, adjusting value to

4323

and press 

MODE

  key to confirm. 

4) Restart the power on, we can see the communication setting parameters in the “setting mode”. 

5) If CTA in lock status, we can press 

MODE

 and 

  Keys as the same time to release lock status. 

 

 

Timer Function 

There are counting up/down modes, several counting units and output modes to choose from in timer function. 
 

:  Select counting up 

  or counting down

 

:  Setup the output time of timer, from 0 to 99.99 secs. 0= Hold output 

:  Setup output modes 

 

:  Setup the counting unit of the timer. 

 

  sec 

0.01  ~  9,999.99 A unit = 10ms. 

Max. counting = 9,999.99 secs.

 

 

  sec 

0.1  ~  99,999.9 

A unit = 0.1sec. 

Max. counting = 99,999.9 secs. 

 

  sec 

1  ~  999,999 

A unit = 1 sec. 

Max. counting = 999,999 secs. 

 

  min, sec 

0.01  ~  9,959.99 A unit = 0.01 sec. Max. counting = 5,999.99 secs. 

 

  min, sec 

0.1  ~  99,959.9 

A unit = 0.1 sec. 

Max. counting = 59,999.9 secs. 

 

  min 

0.1  ~  99,999.9 

A unit = 0.1 min.  Max. counting = 99,999.9 mins. 

 

  min 

1  ~  999,999 

A unit = 1 min. 

Max. counting = 999,999 mins. 

 

  hr, min, sec  1  ~  995,959 

A unit = 1 sec. 

Max. counting = 359,999 secs (100hr) 

 

  hr, min 

1  ~  999,959 

A unit = 1 min. 

Max. counting = 35,999,999 secs 
(10,000hr) 

 

  hr 

1  ~  999,999 

A unit = 1 hr. 

Max. counting = 999,999 hrs 

 

 

Power signal

Start signal

Pause signal

Clear signal

Up

Down

0

0

SV

SV

Signal On Delay 1

t

t

Output signal

 

 

Power signal

Start signal

Pause signal

Clear signal

Output signal

Up

Down

0

0

SV

SV

Signal On Delay 2

t

t

VARITEL INGENIERIA ELECTRONICA S.A.

[email protected] - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545

Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina. 

Содержание CTA4000A Series

Страница 1: ...ected to proper terminals 6 Keep away from high voltage and high frequency environment during installation in case of interference 7 Prevent using the device in premises which contain Dust or corrosiv...

Страница 2: ...operation mode for more than 3 seconds to enter configuration mode Press MODE once to switch among parameters To return to operation mode press MODE for more than 3 seconds Ordering Information CTA 2...

Страница 3: ...data or not while switching off power MODE Setup pre scale value MODE Setup the decimal point MODE Setup the pulse width of output 2 MODE Tachometer Select a function MODE Setup output mode of Tachome...

Страница 4: ...from 0 to 99 99 secs 0 Hold output Setup output modes Setup the counting unit of the timer sec 0 01 9 999 99 A unit 10ms Max counting 9 999 99 secs sec 0 1 99 999 9 A unit 0 1sec Max counting 99 999 9...

Страница 5: ...l Pause signal Clear signal Output signal Up Down SV SV Repeat Cycle 0 0 timer output set as 0 Power signal Start signal Pause signal Clear signal Output signal Up Down SV SV Repeat Cycle t t t timer...

Страница 6: ...s include 1 stage counting 2 stage counting batch counting total counting and dual counting 1 stage Only 1 SV is allowed See output modes of counter 2 stage 2 SVs 2 PVs are allowed See output modes of...

Страница 7: ...A n n 1 n 2 n 3 n 4 n 5 H L H L CP1 CP2 0 Present Value CP1 Counter input prohibited CP2 Counter input Note has to be larger than width of min Input signal A Command counting up down UD_A Individual c...

Страница 8: ...t the counting stops Recounting starts and Output 2 pulse executes after reset signal is over S When PV SV1 Output 1 is enabled When PV SV2 Output 2 is enabled T When PV SV1 Output 1 is enabled When P...

Страница 9: ...OUT2 OUT1 Output mode setting Input mode Up Down Up Down A B C K P Q A T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T VARITEL INGENIERIA ELECTRONICA S A info varitel c...

Страница 10: ...RTU mode Function codes 03H register read and 06H single register write Function code 03H can read maximum 8 words at a time ASCII Mode Register Read 03H Response Register Write 06H Response Start ch...

Страница 11: ...ter Content Remark 1000H 0 V V V PV1 Low byte 1001H 0 V V V PV1 High byte 1002H 0 V PV2 Low byte 1003H 0 V PV2 High byte Available on batch total dual counter and mixed mode 1004H 0 V V V SV1 Low byt...

Страница 12: ...Tachometer Function Measuring Rotation speed Measuring pulse width and determining current frequency Output methods Lo Lo Lo Hi Hi Lo Hi Hi OUT2 set value Measurement value OUT1 set value OUT1 OUT2 OU...

Страница 13: ...eed ON 10KCPS OFF 30CPS Unit of Timer See Table 2 Counting speed ON 10kHz OFF 30Hz 4 Output mode of counter See Table 3 Output mode of Timer See Table 3 Output mode of Tachometer See Table 3 3 Output...

Страница 14: ...D series Multi function input pin Counter Timer Tachometer Timer Counter CP1 CP1 CP1 CP2 Gate Gate Reset1 Reset1 Reset1 Reset1 Reset2 Start Start VARITEL INGENIERIA ELECTRONICA S A info varitel com ww...

Страница 15: ...he top and bottom of the controller and push the mounting bracket forward until the bracket stops at panel wall 3 Insert and tighten screws on bracket to secure the controller in place VARITEL INGENIE...

Отзывы: