l
7
Minimum 18 in.
2-1
2-2
3-1
2. Connecting the duct
CAUTION:
All ducting must comply with local
and national building codes.
a. Insert the duct into the duct connector and tape
all duct work connections to make them secure
and air tight.
b. Do not install the unit where ducts are
configured as shown in Figure 2-2.
Install the duct with a gradient of 1°-2° to the
outside.
3. Remove the fan junction box cover
a
. Using wire
nuts (not supplied), connect house wires to fan
wires
b
as shown in the wiring diagram on page 9.
Wire connections are as follows: black to live switch
wire, white to neutral, green to ground. Reattach
fan junction box cover
c
.