Delta BreezRadiance RAD110LED Скачать руководство пользователя страница 12

l

12

TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSE

CORRECTIVE ACTION

The fan is not turning on

1.  Power off
2.  Faulty switch
3.  Faulty wire connection

1.  Make sure power supply is on.
2.  Test or replace switch.
3.  Check wire in switch box.

The fan seems louder 

than it should

1.  CFM is too great
2.  Damper not working properly or 

damaged

3.  Bend in duct too close to fan 

discharge

4. 

Fan discharge reduced to fit 

smaller duct

5.  Fan body not securely attached

1.  Be sure CFM rating on the fan matches the size of your room.
2.  Be sure damper is opening and closing properly. If the damper 

has become damaged, please call Customer Service.

3.  Be sure you do not have any sharp bends in duct closer than 

18 in. to the fan discharge.

4.  Use recommended size ducting to reduce fan noise.
5.  Be sure the fan is securely attached to your ceiling joists.

The fan is not clearing 

the room

1. 

Insufficient intake airfow within 

room

2. 

Insufficient CFM

1.  Be sure a door or window is slightly ajar or opened to allow 

airflow. The fan is not able to draw air out of the room without 

enough airflow to draw in from.

2.  Be sure the CFM rating on the fan matches the requirements 

for your room size.

The light is not turning on

1.  Power off
2.  Faulty switch
3.  Faulty wire connection

1.  Make sure power supply is on.
2.  Test or replace switch.
3.  Check wire in switch box.

The heater is not heating 

than it should

1.  Faulty switch
2.  Faulty wire connection
3.  Filter is not clean

1.  Test or replace switch.
2.  Check wire in switch box.
3. 

Remove dust from filter.

WARRANTY

DELTA ELECTRONICS THREE YEAR LIMITED WARRANTY
Delta Electronics Inc. (“Delta Electronics”) warrants to the original consumer purchaser in the USA that the Breez ventilation fan 

products will be free from defects in material or workmanship. This warranty is limited to three (3) years from the original date of 

purchase.
Limitations and Exclusions
1.  During the warranty period, a replacement for any defective product will be supplied free of charge for installation by the consumer. 

The warranty provided herein does not cover charges for labor or other costs incurred in the troubleshooting, repair, removal, and 

installation service.

2.  All returns of defective parts or products must include the product model number, and must be made through an authorized Delta 

Electronics distributor. Authorized returns must be shipped prepaid. Repaired or replacement products will be shipped by Delta 

Electronics F.O.B. shipping point.

3.  Delta Electronics shall not be liable for any indirect, incidental, consequential, punitive, or special damages arising out of or in 

connection with products use or performance, regardless of the form of action whether in contract, tort (including negligence), strict 

product liability or otherwise.

4. 

This warranty does not extend to fluorescent lamp starters and tubes.

5.  The warranty does not cover if user does not comply with manufacturer’s installation manual.
6.  To qualify for warranty service, you must notify Delta Electronics at the address or telephone number below.
7.  Delta Electronics shall have no liability to the original owner-user with respect to any defect caused by abuse, misuse, neglect, 

improper transportation or storage, improper testing, improper installation, improper operation, improper use, improper maintenance, 

improper repair, improper alteration, improper modification, tempering or accident of products or parts thereof, or unusual 

deterioration or degradation of products or parts thereof due to a physical environment beyond the requirements of products' 

specifications.

Address: 46101 Fremont Boulevard, Fremont, CA 94538
US Toll Free Number: 1-888-979-9889
www.deltabreez.com

5016234000

Содержание BreezRadiance RAD110LED

Страница 1: ...reparation Assembly Instructions Wiring Instructions Operating Instructions Care and Maintenance Dimensions Product Specification Troubleshooting Warranty 2 3 4 5 9 9 10 11 11 12 12 READ AND SAVE THES...

Страница 2: ...CONTENTS PART DESCRIPTION QTY 1 Fan Body 1 2 Duct Connector 1 3 Grille 1 HARDWARE CONTENTS Images are not shown in actual scale 4 Suspension Bracket 8 Wood Screw 4 x 25 1 Short Machine Screw M4 x 5 1...

Страница 3: ...y questions please call the manufacturer Installation work must be carried out by a qualified person s in accordance with all local and safety codes including the rules for fire rated construction For...

Страница 4: ...tions may vary depending on how the previous bath fan was installed Supplies necessary for the installation of your bath fan are not all included However most are available at your local home improvem...

Страница 5: ...AUTION Check area above installation location to ensure that Duct work can be run and the area is sufficient for proper ventilation Wiring can be run to the planned location No wiring or other obstruc...

Страница 6: ...he fan body 1 between joists Make sure the fan body is level and perpendicular with the joist and flush with ceiling surface c Allow for thickness of the ceiling board used in your application Fan bod...

Страница 7: ...tight b Do not install the unit where ducts are configured as shown in Figure 2 2 Install the duct with a gradient of 1 2 to the outside 3 Remove the fan junction box cover a Using wire nuts not supp...

Страница 8: ...eceptacle marked Vent Check the plug from the heating unit into the receptacle marked Heat b Plug the Light Connector into the receptacle marked Light 3 Attach grille 2 by pinching mounting springs a...

Страница 9: ...itch where it can be reached from a tub shower 3 Using wire nuts not included connect house power wires to fan wires 4 12 AWG is the smallest conductor that may be used for branch circuit wiring Each...

Страница 10: ...llow water to enter the motor heater and LED module Do not immerse metal parts in water Do not immerse resin parts in water over 140 Fahrenheit Turn off power source Review all safety precautions 1 Sq...

Страница 11: ...D Air flow 0 1 in WG 110 CFM Noise 0 7 Sones Voltage 120V Hertz 60Hz Power Consumption 1650W Duct Diameter 4 in Weight 14 8 lbs Main Light Output 850 Lumens TYPE IC INHERENTLY PROTECTED THERMALLY PROT...

Страница 12: ...fects in material or workmanship This warranty is limited to three 3 years from the original date of purchase Limitations and Exclusions 1 During the warranty period a replacement for any defective pr...