background image

2- ENG

A08184

SAFETY GUIDELINES - DEFINITIONS

Indicates an 
imminently hazardous 

situation which, if not avoided, 

will result 

in 

death or serious injury.

Indicates a potentially  
hazardous situation 

which, if not avoided, 

could result in 

death or serious injury.

Indicates a potentially 
hazardous situation 

which, if not avoided, 

may result in minor 

or moderate injury.

Used without the 
safety alert symbol 

indicates a potentially hazardous situation 
which, if not avoided, 

may result in  

property damage

.

This manual contains information that is important for you to know and 

understand. This information relates to protecting 

YOUR SAFETY and 

PREVENTING EQUIPMENT PROBLEMS. To help you recognize this 

information, we use the symbols below. Please read the manual and pay 

attention to these symbols.

IMPORTANT SAFETY INSTRUCTIONS

Some dust created by power sanding, sawing, grinding, 

drilling, and other construction activities contains 

chemicals known (to the State of California) to cause cancer, birth defects 

or other reproductive harm. Some example of these chemicals are:
• 

lead from lead-based paints

• 

crystalline silica from bricks and cement and other masonry products

• 

arsenic and chromium from chemically-treated lumber

Your risk from these exposures varies, depending on how often you do 

this type of work. To reduce your exposure to these chemicals: work in 

a well ventilated area, and work with approved safety equipment, always 

wear MSHA/NIOSH approved, properly fitting face mask or respirator when 

using such tools.
When using air tools, basic safety precautions should always be followed 

to reduce the risk of of personal injury.

Содержание 66-651-1

Страница 1: ...ght 2004 Delta Machinery To learn more about DELTA MACHINERY visit our website at www deltamachinery com For Parts Service Warranty or other Assistance please call 1 866 422 4286 Oil Free Air Compress...

Страница 2: ...the symbols below Please read the manual and pay attention to these symbols IMPORTANT SAFETY INSTRUCTIONS Some dust created by power sanding sawing grinding drilling and other construction activities...

Страница 3: ...roperty damage To reduce the risk of fire do not allow the compressor to operate unattended Always operate the compressor in a well ventilated area free of combustible materials gasoline or solvent va...

Страница 4: ...ndensed water from tank causing rust and thinning of the steel tank Modifications or attempted repairs to the tank Unauthorized modifications to the unloader valve safety valve or any other components...

Страница 5: ...ect voltage and adequate fuse protection Sprayed materials such as paint paint solvents paint remover insecticides weed killers may contain harmful vapors and poisons Work in an area with good cross v...

Страница 6: ...thing WARNING Risk of Falling A portable compressor can fall from a table workbench or roof causing damage to the compressor and could result in serious injury or death to the operator Always operate...

Страница 7: ...parts WARNING Risk of Unsafe Operation Unsafe operation of your air compressor could lead to serious injury or death to you or others HAZARD WARNING Risk of Serious Injury or Property Damage When Tran...

Страница 8: ...starts is called cut in pressure Cut Out Pressure When an air compressor is turned on and begins to run air pressure in the air tank begins to build It builds to a certain high pressure before the mot...

Страница 9: ...t be lifted or pushed up a ramp Assemble Rubber Feet 1 Attach rubber feet with the screws provided as shown in previous figure 2 Tighten securely Rubber Feet Screw Nut Wheel Shoulder Bolt ASSEMBLY Too...

Страница 10: ...se if there are signs of damage 4 If these grounding instructions are not completely understood or if in doubt as to whether the compressor is properly grounded have the installation checked by a qual...

Страница 11: ...and minimum branch circuit requirements Certain air compressors can be operated on a 15 amp circuit if the following conditions are met 1 Voltage supply through branch circuit is 15 amps 2 Circuit is...

Страница 12: ...indicates the reserve air pressure in the tank Regulator Controls the air pressure shown on the outlet pressure gauge Turn the knob clockwise to increase pressure and counterclockwise to decrease pre...

Страница 13: ...the compressor for 15 minutes Make sure the drain valve is open and there is minimal air pressure build up in tank 6 After 15 minutes close the drain valve clockwise The air receiver will fill to cut...

Страница 14: ...NOTE The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick connect Too much air pressure causes a hazardous risk of bursting Check the manufacturer s maxi...

Страница 15: ...e type of valve To Drain Tank 1 Set the On Auto Off lever to OFF 2 Turn the regulator knob counterclockwise to set the outlet pressure to zero 3 Remove the air tool or accessory 4 Pull ring on safety...

Страница 16: ...o Drain Tank in the Maintenance section 2 Unplug outfit 3 Using an adjustable wrench loosen outlet tube nut at air tank and pump Carefully move outlet tube away from check valve 4 Using an adjustable...

Страница 17: ...2 Unplug compressor 3 Remove the outlet pressure gauge and quick connect if equipped from the regulator 4 Remove the regulator 5 Apply pipe sealant tape to the nipple 6 Assemble the regulator and ori...

Страница 18: ...roximately 20 psi Release safety valve ring 6 Drain water from air tank by opening drain valve on bottom of tank Water will condense in the air tank If not drained water will corrode and weaken the ai...

Страница 19: ...ttings where air can be heard escaping Check fittings with soapy water solution Do Not Overtighten Air leaks at fittings Air leaks at pressure switch release valve Defective pressure switch release va...

Страница 20: ...essor is not supplying enough air to operate accessories Prolonged excessive use of air Compressor is not large enough for air requirement Hole in hose Check valve restricted Air leaks Restricted air...

Страница 21: ...ch will automatically reset Tank pressure exceeds pressure switch cut in pressure Motor will start automatically when tank pressure drops below cut in pressure of pressure switch Extension cord is wro...

Страница 22: ...22 ENG A08184 AIR COMPRESSOR DIAGRAM Torque 5 7 ft lbs 5 24 26 27 28 25 9 10 21 15 17 6 10 11 14 18 4 3 Torque 9 12 ft lbs 2 1 Torque 15 25 ft lbs 32 31 Torque 100 120 in lbs 8 29 30 19 23 22 5 20...

Страница 23: ...1 8 1 4NPT 14 Z D26611 Pressure Switch 15 D24888 Nipple 1 4 18 NPT x 2 1 2 17 TIA 4150 Safety Valve 18 D26615 Cord Assembly 19 D23138 Wheel 9 2 20 AC 0609 Handle 21 SS 1286 Nipple 1 4 18 NPT 22 D21172...

Страница 24: ...ENG A08184 AIR COMPRESSOR PUMP DIAGRAM Torque 51 63 in lbs Torque 100 120 in lbs Torque 100 120 in lbs Torque 7 10 ft lbs Torque 42 48 in lbs 83 84 85 90 89 87 81 80 91 78 72 70 74 73 76 79 92 93 77...

Страница 25: ...linder Sleeve 79 Connecting Rod Assembly 80 SSG 8156 O Ring 81 Z AC 0032 Valve Plate Assembly 83 ACG 45 O Ring 84 AC 0037 Head 85 SSF 927 Screw 1 4 20 x 1 1 8 4 87 Muffler Intake 88 Screen Filter 89 D...

Страница 26: ...ser Air compressors with 60 and 80 gallon tanks will be inspected at the site of installation Contact the nearest Authorized Warranty Service Center that provides on site service calls for service cal...

Отзывы: