![delta-mobrey DMSP400 Series Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/delta-mobrey/dmsp400-series/dmsp400-series_user-manual_2478564017.webp)
17 / 53
Damping time setting
(Check for a
valid echo as above)
Action
Led state following the action
1) Press ENTER
E
button steadily
= DMSP400/500 in programming mode
2) Press any of the NEXT ,
UP ,
DOWN
buttons steadily
–
10 sec
=
–
30 sec
–
60 sec
3) Release buttons
= Programming completed
RESET: Returning to the default
(Check for a valid echo as above)
Action
Led state following the action
1) Press NEXT button steadily
= DMSP400/500 in programming mode
2) Press ENTER
E
button steadily
= Default loaded
Indication of mistakes (by LEDs) made during programming
Action
Led state following the action
Possible correction
Attempted programming
= blinking twice = no Echo
Find a valid Echo
Attempted programming
= blinking three times = no access possible
With Display Module only See 5.2 (P99)
Attempted programming
= blinking four times = DMSP400/500 not in
Level Measurement Mode
With Display Module only See 5.2 (P01)