VIVOTEK
User's Manual - 175
© 2022 VIVOTEK INC. All Right Reserved
36
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
integer>
reset
0,
<positive
integer>
7/6
Restart the server after <value> seconds
if <value> is non-negative.
restoreexceptnet
0,
<positive
integer>
7/6
Restore the system parameters to default
values except (ipaddress, subnet, router,
dns1, dns2, pppoe).
This command can cooperate with other
“restoreexceptXYZ” commands. When
cooperating with others, the system
parameters will be restored to the
default value except for a union of the
combined results.
restoreexceptdst
0,
<positive
integer>
7/6
Restore the system parameters to default
values except all daylight saving time
settings.
This command can cooperate with other
“restoreexceptXYZ” commands. When
cooperating with others, the system
parameters will be restored to default
values except for a union of combined
results.
restoreexceptlang
0,
<positive
integer>
7/6
Restore the system parameters to default
values except the custom language file
the user has uploaded.
This command can cooperate with other
“restoreexceptXYZ” commands. When
cooperating with others, the system
parameters will be restored to the
default value except for a union of the
combined results.
restoreexceptvadp
0,
<positive
integer>
7/6
Restore the system parameters to default
values except the vadp parameters and
VADP modules that stored in the system.
This command can cooperate with other
“restoreexceptXYZ” commands. When
cooperating with others, the system
parameters will be restored to the
default value except for a union of the
combined results.
restoreexceptfocusvalu
e
0,
<positive
integer>
7/6
Restore the system parameters to default
values except zoom and focus value.
This command can cooperate with other
“restoreexceptXYZ” commands. When
cooperating with others, the system
© 2022 VIVOTEK INC. All Right Reserved
37
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
parameters will be restored to the
default value except for a union of the
combined results.
* Only available when
"capability_image_c<0~(n-
1)>_remotefocus" != 0.
restoreexceptlen
0,
<positive
integer>
7/6
Restore the system parameters to default
values except lens profile.
This command can cooperate with other
“restoreexceptXYZ” commands. When
cooperating with others, the system
parameters will be restored to the
default value except for a union of the
combined results.
* Only available when
"capability_image_c<0~(n-
1)>_lensconfiguration_support" != 0.
connection_timeout
<integer>
6/6
Session connection timeout interval.
* Only available when
"capability_taics_support" = 1.
7.1.1
System.Info
Subgroup of
system
:
info
(The fields in this group are unchangeable.)
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
modelname
string[40]
0/7
Internal model name of the server
extendedmodelname string[40]
0/7
ODM specific model name of server (eg.
DCS-5610). If it is not an ODM model,
this field will be equal to “modelname”
serialnumber
<mac address>
1/7
12 characters MAC address (without
hyphens).
firmwareversion
string[40]
0/7
Firmware version, including model,
company, and version number in the
format:<MODEL-BRAND-VERSION>
language_count
<positive
integer>
0/7
Number of webpage languages available
on the server.
language_i<0~(count-
1)>
string[16]
language_i0 :
English
language_i1 :
Deutsch
language_i2 :
0/7
Available language lists.