Chapter 4 Parameters
|
4-42
Revision Nov. 2008, VLE1, SW V1.03
02-10
Digital Input Operation Direction
Unit: 1
Control
mode
VF
VFPG
SVC
FOCPG TQCPG FOCPM
Factory setting: 0
Settings
0 ~ 65535
This parameter is used to set the input signal level and it won’t be affected by the
SINK/SOURCE status.
Bit0 is for FWD terminal, bit1 is for REV terminal and bit2 to bit9 is for MI1 to MI8.
User can change terminal status by communicating.
For example, MI1 is set to 1 (multi-step speed command 1), MI2 is set to 2 (multi-step speed
command 2). Then the f 2
nd
step speed command=1001(binary)=9 (Decimal). Only
need to set Pr.02-10=9 by communication and it can forward with 2
nd
step speed. It doesn’t
need to wire any multi-function terminal.
bit9 bit8 bit7 bit6 bit5 bit4
bit3
bit2 bit1 bit0
MI8 MI7 MI6 MI5 MI4 MI3
MI2
MI1 REV FWD
02-11
Multi-function Output 1 RA, RB, RC (Relay1)
Factory Setting: 11
02-12
Multi-function Output 2 MRA, MRC (Relay2)
Factory Setting: 1
02-13
Multi-function Output 3 (MO1)
02-14
Multi-function Output 4 (MO2)
02-15
Multi-function Output 5 (MO3) (need to use with EMVL-IODA01)
02-16
Multi-function Output 6 (MO4) (need to use with EMVL-IODA01)
02-17
Multi-function Output 7 (MO5) (need to use with EMVL-IODA01)
02-18
Multi-function Output 8 (MO6) (need to use with EMVL-IODA01)
02-19
Multi-function Output 9 (MO7) (need to use with EMVL-IODA01)
02-20
Multi-function Output 10 (MO8) (need to use with EMVL-IODA01)
02-21
Multi-function Output 11 (MO9) (need to use with EMVL-IODA01)
02-22
Multi-function Output 12 (MO10) (need to use with EMVL-IODA01)
Factory Setting: 0
Settings
0-41
Control Mode
Settings
VF
VFPG
SVC
FOCPG TQCPG FOCPM
0: No function
○
○
○
○
○
○
1: Operation indication
○
○
○
○
○
○
Содержание Elevator Drive VFD-VL
Страница 1: ......
Страница 2: ......
Страница 3: ......
Страница 20: ...Chapter 1 Introduction Revision Nov 2008 VLE1 SW V1 03 1 11 1 2 5 Cutout Dimensions 7 5 15HP 5 5 11kW frame C...
Страница 21: ...Chapter 1 Introduction 1 12 Revision Nov 2008 VLE1 SW V1 03 20 30HP 15 22kW frame D...
Страница 25: ...Chapter 1 Introduction 1 16 Revision Nov 2008 VLE1 SW V1 03 This page intentionally left blank...
Страница 193: ...Chapter 6 Fault Code Information and Maintenance 6 16 Revision Nov 2008 VLE1 SW V1 03 This page intentionally left blank...
Страница 197: ...Appendix A Specifications A 4 Revision Nov 2008 VLE1 SW V1 03 This page intentionally left blank...
Страница 205: ...Appendix B Accessories B 8 Revision Nov 2008 VLE1 SW V1 03 VFDB4132 VFDB4132 CHARGE ACT OC OH...
Страница 236: ...Appendix B Accessories Revision Nov 2008 VLE1 SW V1 03 B 39 Order P N RF110B43CA 60 33 200 120 398 382 26 20 382 7 0...
Страница 237: ...Appendix B Accessories B 40 Revision Nov 2008 VLE1 SW V1 03 Order P N 50TDS4W4C Order P N 100TDS84C...
Страница 238: ...Appendix B Accessories Revision Nov 2008 VLE1 SW V1 03 B 41 Order P N 200TDDS84C...
Страница 239: ...Appendix B Accessories B 42 Revision Nov 2008 VLE1 SW V1 03 Order P N 150TDS84C Order P N 180TDS84C...
Страница 243: ...Appendix B Accessories B 46 Revision Nov 2008 VLE1 SW V1 03 This page intentionally left blank...
Страница 251: ...Appendix C How to Select the Right AC Motor Drive C 8 Revision Nov 2008 VLE1 SW V1 03 This page intentionally left blank...