Chapter 4 Parameters
|
Revision Nov. 2008, VLE1, SW V1.03 4-29
Group 1 Basic Parameters
01-00
Maximum Output Frequency
Unit: 0.01
Control
mode
VF
VFPG
SVC
FOCPG TQCPG FOCPM
Factory setting: 60.00/50.00
Settings
10.00 to 120.00Hz
This parameter determines the AC motor drive’s Maximum Output Frequency. All the AC
motor drive frequency command sources (analog inputs 0 to +10V, 4 to 20mA and -10V to
+10V) are scaled to correspond to the output frequency range.
01-01
1st Output Frequency Setting
Unit: 0.01
Control
mode
VF
VFPG
SVC
FOCPG TQCPG FOCPM
Factory setting: 60.00/50.00
Settings 0.00~120.00Hz
It is for the base frequency and motor rated frequency.
This value should be set according to the rated frequency of the motor as indicated on the
motor nameplate. If the motor is 60Hz, the setting should be 60Hz. If the motor is 50Hz, it
should be set to 50Hz.
01-02
1st Output Voltage Setting
Unit: 0.1
Control
mode
VF
VFPG
SVC
FOCPG TQCPG FOCPM
Settings 230V series 0.1 to 255.0V
Factory Setting: 220.0
460V series 0.1 to 510.0V
Factory Setting: 440.0
It is for the base frequency and motor rated frequency.
This value should be set according to the rated voltage of the motor as indicated on the motor
nameplate. If the motor is 220V, the setting should be 220.0. If the motor is 200V, it should be
set to 200.0.
There are many motor types in the market and the power system for each country is also
difference. The economic and convenience method to solve this problem is to install the AC
motor drive. There is no problem to use with the different voltage and frequency and also can
amplify the original characteristic and life of the motor.
01-03
2nd Output Frequency Setting
Unit: 0.01
Control
mode
VF
VFPG
Factory setting: 0.50
Settings
0.00~120.00Hz
Содержание Elevator Drive VFD-VL
Страница 1: ......
Страница 2: ......
Страница 3: ......
Страница 20: ...Chapter 1 Introduction Revision Nov 2008 VLE1 SW V1 03 1 11 1 2 5 Cutout Dimensions 7 5 15HP 5 5 11kW frame C...
Страница 21: ...Chapter 1 Introduction 1 12 Revision Nov 2008 VLE1 SW V1 03 20 30HP 15 22kW frame D...
Страница 25: ...Chapter 1 Introduction 1 16 Revision Nov 2008 VLE1 SW V1 03 This page intentionally left blank...
Страница 193: ...Chapter 6 Fault Code Information and Maintenance 6 16 Revision Nov 2008 VLE1 SW V1 03 This page intentionally left blank...
Страница 197: ...Appendix A Specifications A 4 Revision Nov 2008 VLE1 SW V1 03 This page intentionally left blank...
Страница 205: ...Appendix B Accessories B 8 Revision Nov 2008 VLE1 SW V1 03 VFDB4132 VFDB4132 CHARGE ACT OC OH...
Страница 236: ...Appendix B Accessories Revision Nov 2008 VLE1 SW V1 03 B 39 Order P N RF110B43CA 60 33 200 120 398 382 26 20 382 7 0...
Страница 237: ...Appendix B Accessories B 40 Revision Nov 2008 VLE1 SW V1 03 Order P N 50TDS4W4C Order P N 100TDS84C...
Страница 238: ...Appendix B Accessories Revision Nov 2008 VLE1 SW V1 03 B 41 Order P N 200TDDS84C...
Страница 239: ...Appendix B Accessories B 42 Revision Nov 2008 VLE1 SW V1 03 Order P N 150TDS84C Order P N 180TDS84C...
Страница 243: ...Appendix B Accessories B 46 Revision Nov 2008 VLE1 SW V1 03 This page intentionally left blank...
Страница 251: ...Appendix C How to Select the Right AC Motor Drive C 8 Revision Nov 2008 VLE1 SW V1 03 This page intentionally left blank...