Chapter 4 Parameters
|
4-80
Revision Nov. 2008, VLE1, SW V1.03
07-23
Low Torque Offset
Unit: 0.1
Control
mode
SVC
FOCPG
TQCPG FOCPM
Factory Setting: 10.0
Settings
0.0
to
100.0%
When it is set to 3, the source of torque offset will decide to Pr.07-21, Pr.07-22 and Pr.07-23
by the multi-function input terminals setting (19, 20 or 21). The motor rated torque is 100%.
07-24
Forward Motor Torque Limit
Unit: 1
07-25
Forward Regenerative Torque Limit
Unit: 1
07-26
Reverse Motor Torque Limit
Unit: 1
07-27
Reverse Regenerative Torque Limit
Unit: 1
Control
mode
FOCPG
TQCPG
FOCPM
Factory Setting: 200
Settings
0 to 500%
The motor rated torque is 100%. The settings for Pr.07-24 to Pr.07-27 will compare with Pr.03-
00=5, 6, 7, 8. The minimum of the comparison result will be torque limit.
Positive
torque
Negative
torque
speed
06-11 current limit
06-11 current limit
06-11 current limit
06-11 current limit
Reverse motor mode
Forward motor mode
Forward motor mode
Reverse motor mode
The level of torque limit will be
the min. value of following three values
1. torque limit of Pr.07-24 to Pr.07-26
2. Torque limit of external analog terminals
3. Pr.06-11 current limit
External analog terminals
Pr.03-00~02
5: positive torque limit
8: positive/negative torque limit
7: regenerative torque limit
External analog terminals
Pr.03-00~02
5: positive torque limit
8: positive/negative torque limit
External analog terminals
Pr.03-00~03-02
6: negative torque limit
8: positive/negative torque limit
External analog terminals
Pr.03-00~03-02
6: negative torque limit
8: positive/negative torque limit
Pr.07-27
Reverse regenerative
torque limit
Pr.07-24
Forward motor
torque limit
Pr.07-25
Forward regenerative
torque limit
Pr.07-26
Reverse motor
torque limit
Quadrant I
Quadrant II
Quadrant III Quadrant IV
speed
Содержание Elevator Drive VFD-VL
Страница 1: ......
Страница 2: ......
Страница 3: ......
Страница 20: ...Chapter 1 Introduction Revision Nov 2008 VLE1 SW V1 03 1 11 1 2 5 Cutout Dimensions 7 5 15HP 5 5 11kW frame C...
Страница 21: ...Chapter 1 Introduction 1 12 Revision Nov 2008 VLE1 SW V1 03 20 30HP 15 22kW frame D...
Страница 25: ...Chapter 1 Introduction 1 16 Revision Nov 2008 VLE1 SW V1 03 This page intentionally left blank...
Страница 193: ...Chapter 6 Fault Code Information and Maintenance 6 16 Revision Nov 2008 VLE1 SW V1 03 This page intentionally left blank...
Страница 197: ...Appendix A Specifications A 4 Revision Nov 2008 VLE1 SW V1 03 This page intentionally left blank...
Страница 205: ...Appendix B Accessories B 8 Revision Nov 2008 VLE1 SW V1 03 VFDB4132 VFDB4132 CHARGE ACT OC OH...
Страница 236: ...Appendix B Accessories Revision Nov 2008 VLE1 SW V1 03 B 39 Order P N RF110B43CA 60 33 200 120 398 382 26 20 382 7 0...
Страница 237: ...Appendix B Accessories B 40 Revision Nov 2008 VLE1 SW V1 03 Order P N 50TDS4W4C Order P N 100TDS84C...
Страница 238: ...Appendix B Accessories Revision Nov 2008 VLE1 SW V1 03 B 41 Order P N 200TDDS84C...
Страница 239: ...Appendix B Accessories B 42 Revision Nov 2008 VLE1 SW V1 03 Order P N 150TDS84C Order P N 180TDS84C...
Страница 243: ...Appendix B Accessories B 46 Revision Nov 2008 VLE1 SW V1 03 This page intentionally left blank...
Страница 251: ...Appendix C How to Select the Right AC Motor Drive C 8 Revision Nov 2008 VLE1 SW V1 03 This page intentionally left blank...