Chapter 3 Connections and Wiring
ASDA-B2
3-40
Revision September 2013
3.5 Serial Communication Connector CN3
CN3 Terminal Layout and Identification
The servo drive can be connected to a PC or controller via a serial communication
connector. Users can operate the servo drive through PC software supplied by Delta
(contact to the dealer). The communication connector/port of Delta servo drive can
provide three common serial communication interfaces: RS-232 and RS-485
connection. RS-232 is mostly be used but is somewhat limited. The maximum cable
length for an RS-232 connection is 15 meters (50 feet). Using RS-485 interface can
allow longer distance for transmission and support multiple drives to be connected
simultaneously.
CN3 Port (Female)
Please read carefully the following note. Improper wiring may
cause damage or injury!
Side View
Rear View
CN3 Terminal Signal Identification
PIN No.
Signal Name
Terminal
Identification
Description
1 Grounding
GND
Ground
2
RS-232 data
transmission
RS-232_TX
For data transmission of the servo drive.
Connected to the RS-232 interface of PC.
3 -
-
Reserved
4
RS-232 data receiving
RS-232_RX
For data receiving of the servo drive.
Connected to the RS-232 interface of PC.
5
RS-485 data
transmission
RS-485(+)
For data transmission of the servo drive
(differential line end)
6
RS-485 data
transmission
RS-485(-)
For data transmission of the servo drive
(differential line driver - end)
NOTE
1)
For the connection of RS-485, please refer to section 8.1 in Chapter 8.
2) There are two kinds of IEEE1394 communication cables available on the market. If the user
uses one kind of cable, which its GND terminal (Pin 1) and its shielding is short-circuited,
the communication may be damaged. Never connect the case of the terminal to the ground
of this kind of communication cable.
VARITEL INGENIERIA ELECTRONICA S.A.
[email protected] - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.