Chapter 7 Servo Parameters
ASDA-B2
7-24
Revision September 2013
D: Source of pulse command
Setting value
Input pulse interface
Remark
0
Open collector for low-speed pulse
CN1 Terminal Identification:
PULSE, SIGN
1
Line driver for high-speed pulse
CN1 Terminal Identification:
PULSE_D, SIGN_D
P1-01
●
CTL
Control Mode and Output Direction
Address: 0102H
0103H
Operation
Interface:
Keypad/Software
Communication
Related Section:
Section 6.1,
Table 7.A
Default:
0
Control
Mode:
ALL
Unit: pulse (P mode), r/min (S mode),
N-m (T mode)
Range: 00 ~ 110
Data Size: 16-bit
Display
Format:
Hexadecimal
Settings:
A: Control mode settings
Mode
PT
S
T
Sz
Tz
Single Mode
00
▲
01
Reserved
02
▲
03
▲
04
▲
05
▲
Multiple Mode
06
▲
▲
07
▲
▲
08
Reserved
09
Reserved
0A
▲
▲