Chapter 3 Connections and Wiring
ASDA-B2
3-26
Revision September 2013
INHP PT,
PT-S
-
Pulses inhibit input. When the drive is in
position mode, if INHP is activated, the
external pulse input command is not valid.
C9/C10
C11/C12
NOTE
1) The DI signals that do not have pin numbers in Tables 3.C are not default DI signals. If the
users want to use these non-default DI signals, the users need to change the settings of
parameters P2-10 ~ P2-17. The “state” of the output function may be turned ON or OFF as
it will be dependant on the settings of parameters P2-10 ~ P2-17. Please refer to section
3.3.3 for details.
The default DI and DO signals in different control mode are listed in the following table
3.F and table 3.G. Although the content of the table 3.F and table 3.G do not provide
more information than the table 3.B and table 3.C above, as each control mode is
separated and listed in different row, it is easy for user to view and can avoid confusion.
However, the Pin number of each signal can not be displayed in the table 3.F and
table 3.G.
Table 3.1 Default DI signals and Control modes
Signal
DI
Code
Function
PT
S
T
Sz
Tz PT-S PT-T
S-T
SON 0x01
Servo
On
DI1
DI1
DI1
DI1
DI1 DI1 DI1
DI1
ARST
0x02
Reset
DI5
DI5
DI5
DI5
DI5
GAINUP 0x03
Gain switching in speed
and position mode
CCLR
0x04
Pulse
clear
DI2
DI2
DI2
ZCLAMP
0x05
Low
speed
CLAMP
CMDINV 0x06
Command input
reverse control
Reserved
0x07
Reserved
Reserved
0x08
Reserved
TRQLM
0x09
Torque
limit
enabled
DI2
DI2
SPDLM
0x10
Speed
limit
enabled
DI2
DI2
STOP
0x46
Motor
stop
SPD0 0x14
Speed command
selection 0
DI3
DI3
DI3 DI3
SPD1 0x15
Speed command
selection 1
DI4
DI4
DI4 DI4
TCM0 0x16
Torque command
selection 0
DI3
DI3
DI3 DI3
DI5