ASDA-B2
Chapter 7 Servo Parameters
Revision September 2013
7-91
Display
Format:
Decimal
Settings:
Refer to P4-11 for explanation.
When executing this auto adjustment, please ensure to cool the servo drive to 25
o
C.
P4-20
DOF1
Analog Monitor Output Drift Adjustment
(MON1)
Address: 0428H
0429H
Operation
Interface:
Keypad / Software
Communication
Related Section:
Section 6.4.4
Default:
Factory setting
Control
Mode:
ALL
Unit: mV
Range: -800 ~ 800
Data Size: 16-bit
Display
Format:
Decimal
Settings:
Please note that when P2-08 is set to 10, the users cannot reset this parameter.
P4-21
DOF2
Analog Monitor Output Drift Adjustment
(MON2)
Address: 042AH
042BH
Operation
Interface:
Keypad / Software
Communication
Related Section:
Section 6.4.4
Default:
0
Control
Mode:
ALL
Unit: mV
Range: -800 ~ 800
Data Size: 16-bit
Display
Format:
Decimal
Settings:
Please note that when P2-08 is set to 10, the users cannot reset this parameter.
P4-22
SAO Analog Speed Input Offset
Address: 042CH
042DH
Operation
Interface:
Keypad / Software
Communication
Related Section: N/A
Default:
0
Control
Mode:
S
Unit: mV
Range: -5000 ~ 5000
Data Size: 16-bit
Display
Format:
Decimal
VARITEL INGENIERIA ELECTRONICA S.A.
[email protected] - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.