VFD-F Series
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
5-28
05 - 17
Time Duration of 1st Step Speed
Factory Setting: 0.0
05 - 18
Time Duration of 2nd Step Speed
Factory Setting: 0.0
05 - 19
Time Duration of 3rd Step Speed
Factory Setting: 0.0
05 - 10
Time Duration of 4th Step Speed
Factory Setting: 0.0
05 - 21
Time Duration of 5th Step Speed
Factory Setting: 0.0
05 - 22
Time Duration of 6th Step Speed
Factory Setting: 0.0
05 - 23
Time Duration of 7th Step Speed
Factory Setting: 0.0
05 - 24
Time Duration of 8th Step Speed
Factory Setting: 0.0
05 - 25
Time Duration of 9th Step Speed
Factory Setting: 0.0
05 - 26
Time Duration of 10th Step Speed
Factory Setting: 0.0
05 - 27
Time Duration of 11th Step Speed
Factory Setting: 0.0
05 - 28
Time Duration of 12th Step Speed
Factory Setting: 0.0
05 - 29
Time Duration of 13th Step Speed
Factory Setting: 0.0
05 - 30
Time Duration of 14th Step Speed
Factory Setting: 0.0
05 - 31
Time Duration of 15th Step Speed
Factory Setting: 0.0
Settings
0.0 to 65500
Unit: 1 /0.1sec
Pr.05-17 to Pr.05-31 correspond to operation time of each step speed defined by Pr.05-00
to Pr.05-14. The maximum setting 65500 seconds will be displayed as t6550. If it is
displayed t6550. that means 6550 seconds.
Note: If a parameter is set to “00” (0 sec), the corresponding step will be skipped. This is
commonly used to reduce the number of program steps.
Содержание AC Drive VFD-F Series
Страница 1: ......
Страница 2: ......
Страница 3: ......
Страница 107: ...VFD F Series DELTA ELECTRONICS INC ALL RIGHTS RESERVED This page intentionally left blank...
Страница 133: ...VFD F Series DELTA ELECTRONICS INC ALL RIGHTS RESERVED This page intentionally left blank...
Страница 142: ...B VFD F Series DELTA ELECTRONICS INC ALL RIGHTS RESERVED B 7 Figure 2 VFDB4132 VFDB4132 CHARGE ACT OC OH...
Страница 161: ...VFD F Series DELTA ELECTRONICS INC ALL RIGHTS RESERVED C 8 KPF CC01 Unit mm inches...