background image

Shenzhen Delong Energy Technology Co.,Ltd

深圳德隆能源有限公司

Address: 9098,DongBian Business Building, MinZhi Road 369, MinZhi Street,Longhua New District, Shenzhen city, Guangdong Province,China

TEL: +86 755 21012989

FAX: +86 755 33815254

2

WARNING

Quality Statement

Proper use and maintenance will ensure that the battery (or battery system) will operate
reliably and consistently for a long period of time.

After receiving the product, please check if the packaging is in good condition. If the packaging

is broken, there may be damage to the product. If there is damage, please contact us.

Anyone who does not use or maintain the battery according to this owner's manual, gives up

any right to warranty.

This battery is to be installed and serviced only by qualied personnel equipped with
appropriate personal protective equipment and following safe electrical work practices.
Always wear eye protection, gloves, apron and mask when working with batteries. Also
remove any metal / conductive jewelry.

Precautions When Working With Batteries

Use caution to eliminate the risk of dropping a metal tool on the battery. It could spark or short
circuit the battery or other electrical parts and could cause an explosion.

Insulated tools are strongly recommended anytime you are working around batteries.

Never smoke or allow a spark or flame near the batteries.

Ensure that someone is within range of your voice or close enough to come to your aid when

you are working near a battery.

Wear complete eye / face protection and gloves. Avoid touching your eyes while

working near batteries.

If you need to disconnect the battery, always remove the negative terminal from the battery

first. Make sure all accessories are turned off so you don

t cause a spark.

Never use or combine this battery with another dissimilar battery.

Batteries are temperature sensitive. For optimum performance, they should be installed in a

stable temperature environment.

Always recycle old batteries. Contact your local recycling center for proper disposal

information.

Contact your suppler or qualitied the battery installer befre wirng in parallel or series

Precautions When Working With Batteries

Use caution to eliminate the risk of dropping a metal tool on the battery. It could spark or short

circuit the battery or other electrical parts and could cause an explosion.

Insulated tools are strongly recommended anytime you are working around batteries.

Never smoke or allow a spark or flame near the batteries.

Ensure that someone is within range of your voice or close enough to come to your aid when

you are working near a battery.

Wear complete eye / face protection and gloves. Avoid touching your eyes while

working near batteries.

If you need to disconnect the battery, always remove the negative terminal from the battery

first. Make sure all accessories are turned off so you don

t cause a spark.

Содержание LFP48200

Страница 1: ...gBian Business Building MinZhi Road 369 MinZhi Street Longhua New District Shenzhen city Guangdong Province China TEL 86 755 21012989 FAX 86 755 33815254 1 Lithium Iron Phosphate Battery User Operation Manual Product Name Lifepo4 Battery Pack Model LFP48200 Wall mounted ...

Страница 2: ...he batteries Ensure that someone is within range of your voice or close enough to come to your aid when you are working near a battery Wear complete eye face protection and gloves Avoid touching your eyes while working near batteries If you need to disconnect the battery always remove the negative terminal from the battery first Make sure all accessories are turned off so you don t cause a spark N...

Страница 3: ...information including voltage current and temperature What s more BMS can balance cells charging and discharging to extend cycle life Multiple batteries can connected in parallel to expand capacity and power in parallel for larger capacity and longer power supporting duration requirements 1 1 Features The whole module is non toxic non polluting and environmentally friendly Cathode material is made...

Страница 4: ...y efficiency 98 Cycle Life 4000 6000 25 Lifespan 10 years Internal Resistance 100mΩ Standard Charge End of charge Voltage 58 8V Max Continuous charge current 100A Recommended charge current 40 A Charge Method 0 2C 0 5A CC CV Standard Discharge End of discharge Voltage 40V Max Continuous Discharge Current 200A Max Pluse Discharge Current 400A 5S Environment Working Temperature 20 55 Recommended Sto...

Страница 5: ...ty No power ALARM Alarm light Battery failure status indicator light red for failure green for normal Battery indicator Battery Capacity Power display six indicator lights show the current power CAN CAN Communication Terminal RJ45 port follow CAN protocol for output batteries information RS232 R232 Communication Terminal RJ11 port follow RS232 protocol for output batteries information RS485 R485 c...

Страница 6: ... active state press the button 3 6s and release it the protection board will sleep and the LED indicator will light up for 0 5 seconds from the lowest battery level light When BMS is in the active state press the button 6 10s and release it the protection plate is reset and all LED lights are on for 1 5 seconds at the same time DIP ADD DIP ADD Switch 4 ADD switches to definite different address co...

Страница 7: ...iver NOTE Use properly insulated tools to prevent accidental electric shock or short circuits If insulated tools are not available cover the entire exposed metal surfaces of the available tools except their tips with electrical tape 2 2 Safety protection It is recommended to wear the following safety gear when dealing with the battery pack 3 Installation 3 1 Package Items For battery module packag...

Страница 8: ...e installer 1 Choose suitable firm wall with thickness greater 2 Use the mounting frame as a template mark the hole position 3 Drill holes according to the hole position 4 Hammer the M8 screws to the above holes and screw the nut Note Do not position screws flush to the wall leave 10 to 20 mm exposed 5 Fix the mounting frame to the screws 6 Raise the battery a little higher than the mounting frame...

Страница 9: ... to put the batteries working with faulty or incompatible inverter 4 It is prohibited to disassemble the battery QC tab removed or damaged 5 In case of fire only dry powder fire extinguisher can be used liquid fire extinguishers are prohibited 6 Please do not open repair or disassemble the battery except staffs from Manufacture or authorized by dealer We do not undertake any consequences or relate...