background image

Operation manual for Ares (Tubular Gel) series 

VALVE

 

REGULATED

 

TUBULAR

 

GEL

 

BATTERY

 

OPERATION

 

MANUAL

 

 
 

OPERATION

 

MANAUL

 

Version

 

3.0

 

N A R A DA

 

P O W E R

 

S O U R C E

 

C O. ,

 

LT D

 

E m a i

 

l :

 

 

[email protected] 

 

 

 

 

Websi

 

te

 

:

 

 

www.tempelgroup.com 

Ares(OPzV)

 

series

Summary of Contents for Ares OPzV Series

Page 1: ...l for Ares Tubular Gel series VALVE REGULATED TUBULAR GEL BATTERY OPERATION MANUAL OPERATION MANAUL Version 3 0 NARADA POWER SOURCE CO LTD Emai l energy tempelgroup com Websi te www tempelgroup com Ar...

Page 2: ...Chapter Two Technical Characteristics 1 Discharge Curve and Discharge Data 2 Charge Curve 3 Internal Resistance and Short Circuit Current Chapter Three Operation and Maintenance 1 Setting Up The Para...

Page 3: ...lations to get the validity handle ways or send the equipment to authorized service center The replacement of battery can only be done by persons who know well about the danger and the prevention When...

Page 4: ...New porous PVC SiO2 separator with low internal resistance 1 3 Initial capacity is above 95 the remaining capacity is above 90 when storage for 3 months 25 C 1 4 Remarkable high rate discharge perform...

Page 5: ...45 206 356 389 28 6OPzV 400 2 400 300 200 145 206 473 505 35 7OPzV 500 2 500 375 250 166 206 473 505 41 6OPzV 600 2 600 450 300 145 206 646 678 49 8OPzV 800 2 800 600 400 191 210 646 678 65 10OPzV 100...

Page 6: ...on manual for Ares Tubular gel series 6 Dimension drawing mm Ares OPzV series 200Ah 600Ah Type 4OPzV200 6OPzV300 6OPzV400 7OPzV500 6OPzV 600 L 102 145 145 166 145 H1 356 356 473 473 646 H 389 389 505...

Page 7: ...mm Ares OPzV series 800Ah 1500Ah 827 795 646 678 678 646 678 646 H H1 GFMJ 1500 GFMJ 1200 L B GFMJ 800 GFMJ 1000 191 80 233 110 140 275 275 140 Type 8OPzV800 10OPzV1000 12OPzV1200 12OPzV1500 L 191 23...

Page 8: ...Operation manual for Ares Tubular gel series 8 Dimension drawing mm 16OPzV 2000...

Page 9: ...Operation manual for Ares Tubular gel series 9 Dimension drawing mm 20OPzV2500 and 24OPzV3000 140 576 110 487 GFMJ 3000 GFMJ 2500 B L 108 Type 20OPzV2500 24OPzV3000 L 478 576 B 110 140...

Page 10: ...the negative plates which prevent generation of Hydrogen Otherwise the oxygen generated from positive diffuses through separator to the negative and the oxygen gas reacts quickly and is recombined in...

Page 11: ...ves at Different Discharge Rates 25 2 Charge Performance Fig 2 2 shows recharge characteristics of 100 DOD battery with current of 0 1C10A and limit voltage of 2 35V Cell 25 It can be found that the f...

Page 12: ...0 52 0 43 1 19 3 10 5 5 8 1 75V 387 320 226 142 104 84 71 8 62 7 51 0 42 4 18 9 10 4 5 7 1 80V 342 293 215 137 102 82 70 1 61 1 49 8 41 1 18 5 10 2 5 5 1 85V 288 247 200 130 99 79 67 9 59 0 48 4 40 6...

Page 13: ...2 1 90V 788 763 580 409 320 268 229 198 159 132 59 5 33 0 17 7 16OPzV2000 End voltage 15min 30min 1h 2h 3h 4h 5h 6h 8h 10h 24h 48h 100h 1 60V 2171 1734 1188 737 532 422 361 318 256 210 94 1 51 7 29 0...

Page 14: ...9 1 85V 496 417 287 194 147 116 97 5 84 1 69 7 58 7 37 9 25 8 1 90V 463 381 256 176 142 111 94 6 76 3 63 2 53 2 34 3 23 3 6OPzV400 End voltage 15min 30min 1h 2h 3h 4h 5h 6h 8h 10h 16h 24h 1 60V 899 71...

Page 15: ...202 5 168 141 3 91 2 62 10OPzV1000 End voltage 15min 30min 1h 2h 3h 4h 5h 6h 8h 10h 16h 24h 1 60V 2176 1723 1319 724 550 438 367 5 318 264 1 221 8 143 2 97 1 1 65V 2072 1632 1227 719 547 435 365 316 2...

Page 16: ...351 1 226 7 154 20OPzV2500 End voltage 15min 30min 1h 2h 3h 4h 5h 6h 8h 10h 16h 24h 1 60V 5429 4299 3291 1806 1374 1091 917 794 659 554 357 242 1 65V 5169 4071 3061 1795 1364 1084 911 788 654 550 355...

Page 17: ...nternal resistance and short circuit current of Narada battery in fully charged state according to IEC60896 If the voltage decrease 0V due to short circuit that can damage the battery Table 2 3 Intern...

Page 18: ...roke Voltage V 44 45 Recover Voltage V 49 50 High Voltage Warning V 57 6 57 6 Low Voltage Warning V 46 47 Temperature Compensate Ratio With Floating Voltage V 0 072 0 072 Temperature Compensate Ratio...

Page 19: ...re curve From Fig 3 1 if the temperature is too low the capacity will decrease for example the capacity will decrease 15 if temperature fell to 0 from 25 and too low temperature will cause battery lon...

Page 20: ...29 2 45 10 2 27 2 43 15 2 26 2 40 20 2 24 2 38 25 2 23 2 35 30 2 22 2 33 35 2 20 2 30 40 2 19 2 28 Fig Float charge and equalization charge voltage curve 3 3 Ambient Temperature Vs Battery Life Tempe...

Page 21: ...ure is below 0 there leaves 80 capacity compared with that at 25 Then you should divide by 0 8 4 To ensure the life of the battery please do not discharge the depth of battery too much You d better co...

Page 22: ...25C10A DOD Charge time h 0 1C10A 0 15C10A Fig 3 4 DOD Vs Charge Time 6 Storage Batteries will experience self discharge in open circuit The result is that the voltage of open circuit is decreased and...

Page 23: ...monthly inspection Measure and record floating voltage of every on line battery If more than two cells voltage is less than 2 18V after temperature adjustment the batteries need to be equalization ch...

Page 24: ...ation etc C Too low or too high temperature We have mentioned that too low temperature will affect the capacity of battery While too high temperature will also cause problems such as water loss life d...

Page 25: ...fe if you use the battery correctly Answer the complaint within 24 hours and deal with them in time Debug the battery according to users requirements on the spot Hold regular training classes about th...

Page 26: ...ype System voltage Battery capacity User Site place Temperature Float voltage Float current Load No Cell series No Charge voltage Discharging Charging voltage vs time Note 1 2 3 4 5 6 7 8 9 10 11 12 1...

Reviews: