If the unit is not working properly, this may be due to small problems that you can easily resolve yourself.

Follow these instructions carefully before contacting your local Authorised Technical Service Centre.

Troubleshooting

PROBLEM

REMEDY

The air conditioner is
completely turned
off

it is not plugged in

there is no electricity

plug in

wait

CAUSE

The unit works but
does not cool the
room

three minutes have not passed since it was
turned on

windows open 

a heat source is operating in the room (burner,
light, etc.) or there are a lot of people

the air outlet hose has come detached from
the coupling

thermostat adjusted too high

air filters clogged

the output of the unit is insufficient for the con-
ditions or size of the room

wait three minutes (safety devi-
ce) before the appliance start
cooling.

•  close the windows
•  eliminate heat sources

•  fit the hose in the coupling

•  lower the thermostat
• clean/replace 

filters

the air conditioner is
on (signal light 

)

but the appliance
doesn't start

9

The notches of the timer are in the rest mode

proceed with a new setting of
the timer

The unit works for
only a short time

there is a kink in the exhaust hose

the exsaust hose is blocked

there are too many curves in the outlet tube

the fan is blocked

position the exhaust hose correctly

check there are no blockages
preventing the discharge of air
to the outside

rearrange the hose correctly 

contact the Service Centre

Содержание Pinguino PAC60

Страница 1: ...PAC 60 PAC 60 Use and maintenance manual...

Страница 2: ...erience all around the world we are constantly improving the quality and performance of Pinguino We are confident that you will be satisfied with your purchase and enjoy the cool comfort created by th...

Страница 3: ...Description 9 10 12 14 15 17 16 18 13 19 20 11 21 CONTROL PANEL 22 24 25 23 26 ACCESSORIES 1 2 3 4 5 6 7 8 27 28...

Страница 4: ...check with a qualified electrician Avoid using extension leads with the unit Before cleaning or maintenance operations always unplug the unit from the socket Do not pull on or place strain on the pow...

Страница 5: ...oved from one room to another in the home or even transferred between different buildings The hot air in your room is passed through a coil cooled by refrigerant gas removing excess heat and moistu re...

Страница 6: ...e unit near a window French win dow or door Open the window French window or door slightly and place the window attachment as shown in figure B 24 23 24 Setting up B C 1 2 A For optimum results If you...

Страница 7: ...Make a hole in a outside wall or through the glass of a window Check the height and dimensions given in figure D 30 cm 30 cm 106 MAX 120 cm MIN 30 cm When the hose is not attached close the hole with...

Страница 8: ...cooling power 23 5 A To open the front panel grip either side of the panel and gently pull the panel towards you and upwards Remove the tank Lifting it forward 5 3 B Turn the tank upside down and rem...

Страница 9: ...ollowing the direction of the arrow until the number 16 is lined up with the triangular pointer the arrows indicates 4 00 P M approximately 12 21 20 19 1 6 pointer N B Never turn the dial in an anti c...

Страница 10: ...or on initial start up 2 You may also experience a slight delay between changing from one function to another 15 14 21 19 15 21 14 21 18 9 10 TURBO POWER The Turbo Power mode was designed to pro vide...

Страница 11: ...linds or draw the curtains do not cover Make sure the unit is located on a level floor If necessary place the two blocking devices under the front wheels 26 Do not rest objects on the air conditioning...

Страница 12: ...t part Alternatively the dust filter included with the appliance may be used in place of the purification filter CLEANING THE RESERVOIR It is recommended that you clean this at least once a month usin...

Страница 13: ...he air conditioner for about half an hour 4 After this drain out all of the liquid remai ning in the collection reservoir and rinse thoroughly During the rinsing process the drainage hose must be open...

Страница 14: ...hermostat adjusted too high air filters clogged the output of the unit is insufficient for the con ditions or size of the room wait three minutes safety devi ce before the appliance start cooling clos...

Страница 15: ...370 m3 h Dimensions width 580 mm height 785 mm depth 435 mm RECOMMENDED OPERATING CONDITIONS Room temperature 21 32 C This appliance contains substances which if released into the atmosphere would da...

Страница 16: ...D e L o n g h i S p A V i a L S e i t z 4 7 3 1 1 0 0 Tr e v i s o I t a l i a t e l 3 9 0 4 2 2 4 1 3 1 f a x 3 9 0 4 2 2 4 1 3 6 4 7 w w w d e l o n g h i c o m 5751008600 06 02...

Отзывы: