Pre p a ra t i o n   f o r   u s e

HOW TO USE THE AIR-CONDITIONER WITH WATER

These air conditioners can use both air and water to cool the condenser (the hot part) of the air
conditioner.

To utilise  the full potential of your air conditioner, the tank 

needs to be filled with water. The water

is used to increase the cooling power and reduce the noise level and energy consumption of the air
conditioner. The water that is used in then expelled from the machine as water vapour through the
exhaust hose 

(it does not go into room).

Always use clean top water (which doesn’t contain salts). As a rule the water will usually last about 8
hours however this depends on the conditions within the room, such as temperature, humidity, insula-
tion and aspect and number of people. In turbo mode the water will also be used more quickly.

You may also use the air-conditioner on air cooling only  (without filling the water tank  if you only requi-
re the lower cooling power).

23

5

A) To  open the front panel

grip either side of the

panel and gently pull the

panel  towards  you and

upwards. Remove the tank

Lifting it forward.

5

3

B) Turn the tank upside down

and remove the plug,
remove the extendible
tube and fill the tank, lea-
ving it on the ground.

C) After  completing the fil-

ling procedure, replace
the extendible hose,
replace the cap and
screw it in tightly.  Return
the tank to its place, with
the writing FRONT clearly
visible. Carefully hold the
panel in the centre and
lower to its closed posi-
tion.

During the "water functioning" operation and in particularly silent locations (eg the bedroom) a 
slight gurgling sound may be heard.  This is completely normal.

IN HIGH HUMIDITY CONDITIONS
Water is extracted from the air in the room, this water is also used to cool the condenser. When
the humidity is particulary high an excess of water may build up in the internal tank. This can be

drained by removing the bung from the drain hose  

and draining into a suitable receptacle.

11

IMPORTANT: if the room temperature is 32°C or over the airconditioner must be operated with with
water in the tank.

2

Содержание Pinguino PAC60

Страница 1: ...PAC 60 PAC 60 Use and maintenance manual...

Страница 2: ...erience all around the world we are constantly improving the quality and performance of Pinguino We are confident that you will be satisfied with your purchase and enjoy the cool comfort created by th...

Страница 3: ...Description 9 10 12 14 15 17 16 18 13 19 20 11 21 CONTROL PANEL 22 24 25 23 26 ACCESSORIES 1 2 3 4 5 6 7 8 27 28...

Страница 4: ...check with a qualified electrician Avoid using extension leads with the unit Before cleaning or maintenance operations always unplug the unit from the socket Do not pull on or place strain on the pow...

Страница 5: ...oved from one room to another in the home or even transferred between different buildings The hot air in your room is passed through a coil cooled by refrigerant gas removing excess heat and moistu re...

Страница 6: ...e unit near a window French win dow or door Open the window French window or door slightly and place the window attachment as shown in figure B 24 23 24 Setting up B C 1 2 A For optimum results If you...

Страница 7: ...Make a hole in a outside wall or through the glass of a window Check the height and dimensions given in figure D 30 cm 30 cm 106 MAX 120 cm MIN 30 cm When the hose is not attached close the hole with...

Страница 8: ...cooling power 23 5 A To open the front panel grip either side of the panel and gently pull the panel towards you and upwards Remove the tank Lifting it forward 5 3 B Turn the tank upside down and rem...

Страница 9: ...ollowing the direction of the arrow until the number 16 is lined up with the triangular pointer the arrows indicates 4 00 P M approximately 12 21 20 19 1 6 pointer N B Never turn the dial in an anti c...

Страница 10: ...or on initial start up 2 You may also experience a slight delay between changing from one function to another 15 14 21 19 15 21 14 21 18 9 10 TURBO POWER The Turbo Power mode was designed to pro vide...

Страница 11: ...linds or draw the curtains do not cover Make sure the unit is located on a level floor If necessary place the two blocking devices under the front wheels 26 Do not rest objects on the air conditioning...

Страница 12: ...t part Alternatively the dust filter included with the appliance may be used in place of the purification filter CLEANING THE RESERVOIR It is recommended that you clean this at least once a month usin...

Страница 13: ...he air conditioner for about half an hour 4 After this drain out all of the liquid remai ning in the collection reservoir and rinse thoroughly During the rinsing process the drainage hose must be open...

Страница 14: ...hermostat adjusted too high air filters clogged the output of the unit is insufficient for the con ditions or size of the room wait three minutes safety devi ce before the appliance start cooling clos...

Страница 15: ...370 m3 h Dimensions width 580 mm height 785 mm depth 435 mm RECOMMENDED OPERATING CONDITIONS Room temperature 21 32 C This appliance contains substances which if released into the atmosphere would da...

Страница 16: ...D e L o n g h i S p A V i a L S e i t z 4 7 3 1 1 0 0 Tr e v i s o I t a l i a t e l 3 9 0 4 2 2 4 1 3 1 f a x 3 9 0 4 2 2 4 1 3 6 4 7 w w w d e l o n g h i c o m 5751008600 06 02...

Отзывы: